0 S <br /> .R r'.7;7 <br /> • <br /> frI y <br /> 11. Supports for solar modules are Installed to spread the dead load across as many roof- <br /> framing members as needed to ensure that no point load exceeds fifty(50)pounds. 1f 0 <br /> PC M2302.2.1(5)] <br /> 12. The photovoltaic modules and supporting structure shall be constructed of <br /> , noncombustible materials or fire-retardant treated wood equivalent to that required for M 0 <br /> the roof construction.[IRC M2302.2.11 <br /> 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, <br /> g El <br /> rodents,and insects.[IRC M2302.2.2] <br /> • 14. PV modules are listed and labeled with a fire classification In accordance with U!1703. El <br /> [SRC M2302.2.3] <br /> • <br /> Comments: • <br /> • <br /> i L:, If you answered yes to all of the above questions,the project qualifies for the over-the- <br /> counter permitting process. <br /> .0 Determine if your project qualifies for an Over-the-Counter electrical permit • <br /> Yes No N/A . <br /> 1. PV modules,inverters,and combiner boxes are identified for use In PV systems. f ❑ <br /> 2. The Inverters are listed and labeled in accordance with U1:1741 and are listed for Et' 0 <br /> utility interaction.[IRC M2302.4) <br /> 3. The AC interconnection point is on the load side of service disconnect.[NEC 690.64(B)] 0 <br /> i <br /> 4. The system meets all current NEC,City and Washington Cities Electrical Code <br /> requirements. <br /> 5. For Split-Buss modules the AC interconnection must be one of the six service 0 0 14 <br /> disconnects. <br /> 6. Maximum load added to the panelboard is based on the rating of the panelboards bus/main OCPD <br /> combination in accordance with NEC 705.12(D)(2)(3)(b),and is limited to(check combination that <br /> applies): <br /> 0225 amp bus/200 amp main OCPD-13,440 AC watts,maximum 70 amp inverter OCPD, <br /> 0225 amp bus/225 amp main OCPD- 8,640 AC watts,maximum 45 amp inverter OCPD. <br /> 0200 amp bus/200 amp main OCPD- 7,860 AC watts,maximum 40 amp inverter OCPD. <br /> 0150 amp bus/150 amp main OCPD- 5,760 AC watts,maximum 30 amp inverter OCPD. <br /> g125 amp bus/125 amp main OCPD- 4,800 AC watts,maximum 25 amp inverter OCPD. <br /> 0125 amp bus/100 amp main OCPD- 9,600 AC watts,maximum 50 amp Inverter OCPD. <br />
The URL can be used to link to this page
Your browser does not support the video tag.