My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6500 MERRILL CREEK PKY BASE FILE 2024-03-01
>
Address Records
>
MERRILL CREEK PKY
>
6500
>
BASE FILE
>
6500 MERRILL CREEK PKY BASE FILE 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 10:43:21 AM
Creation date
2/18/2024 9:44:15 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6500
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
17. Manufactures Specification - Important to follow the manufactures specification El El El <br /> on the correct testing of the device. (Incorrect testing can damage devices) <br /> Manual Fire Alarm Box(Pull Stations): <br /> PASS FAIL N/A <br /> 18. 100%Activation - 100%of Manual Fire Alarm Box(Pull Stations) provided shall be El El El <br /> tested by physical activation. <br /> 19. Location - Manual fire alarm boxes shall be located as follows: El El El <br /> • At a conspicuous, unobstructed, and assessable location. <br /> • Within 60 inches of exit doorway openings. <br /> • Mounted between 42 to 48 inches above the floor. <br /> 20 Addressable-Verify that upon activation of a manual fire alarm box the alarm El El El <br /> signal to the main fire alarm panel is correctly addressed with an accurate <br /> description. <br /> 21. Color- Manual fire alarm boxes shall be red in colors on a background of El El El <br /> contrasting color. <br /> Other Initiation Devices: <br /> PASS FAIL N/A <br /> 22. Other Devices-Combination Detector, Electrical Conductivity Heat Detector, Fire- El El El <br /> Gas Detector, Flame Detector, Pneumatic Rate-of-Rise Tubing Heat Detector, <br /> Projected Beam-Type Detector, Radiant Energy-Sensing Fire Detector, Rate <br /> Compensation Detector, Spark/Ember Detector, Spot-Type Detector shall follow <br /> the manufactures specification on the correct testing of that device. <br /> Step 8: Electrically Locking and/or Self-Closing PASS FAIL N/A <br /> Doors <br /> Door Releases: <br /> 1. Magnetic Door Hold -Verify that all Magnetic Door Hold-Open Release Devices El El El <br /> work when the system is in alarm.The doors shall close completely and latch. <br /> Electrically Locked Doors: <br /> PASS FAIL N/A <br /> 2. Electrically Locked Doors- Electrically locked doors that are part of the required <br /> means or egress shall comply with the following: <br /> • Unlock immediately upon loss of power. <br /> • Unlock upon activation of the fire alarm system and remain unlocked until <br /> the fire alarm condition is manually reset. <br /> • Unlock upon activation of the automatic sprinkler system. <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 4.13.2020 1 Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.