My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6500 MERRILL CREEK PKY BASE FILE 2024-03-01
>
Address Records
>
MERRILL CREEK PKY
>
6500
>
BASE FILE
>
6500 MERRILL CREEK PKY BASE FILE 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 10:43:21 AM
Creation date
2/18/2024 9:44:15 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6500
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12. Flashing Notifications- Indoor strobes must flash 60-120 times/minute and in ❑ ❑ ❑ <br /> spaces such as corridors where more than two visible notification appliances are in <br /> any field of view, they shall flash in synchronization. <br /> 13. Lights- Lights used for fire alarm signaling only or to signal the intent for complete ❑ ❑ ❑ <br /> evacuation shall be clear or nominal white. <br /> 14. Wall Mount-Wall-mounted appliances shall be mounted such that the entire lens ❑ ❑ ❑ <br /> is not less than 80 inches and not greater than 96 inches above the finished floor. <br /> 15. Ceiling Mount-Ceiling-mounted appliances shall be permitted. If ceiling heights ❑ ❑ ❑ <br /> exceed 30 feet, ceiling-mounted visible notification appliances shall be suspended <br /> at or below 30 feet or at the mounting height of a wall mounted visible <br /> notification appliances. <br /> 16. Environment-Verify that all appliances as listed for the environment that they are ❑ ❑ ❑ <br /> located. (walk-in coolers/freezers, etc.) <br /> Step 4: Power Supplies & Trouble Signals PASS FAIL N/A <br /> 1. Reset-Once all notification appliances have been verified and the minimum alarm ❑ ❑ ❑ <br /> time has elapsed, silence the signal and ensure horns and strobes cease. <br /> 2. Clear Panel- Have primary power turned back on and verify that the panel has ❑ ❑ ❑ <br /> been cleared. <br /> 3. Battery Lead- Unplug one battery lead,the panel shall indicate a trouble within ❑ ❑ ❑ <br /> 200 seconds. <br /> 4. Battery Date-Also, ensure the battery manufacture date is written on the ❑ ❑ ❑ <br /> batteries. <br /> 5. Batterie Size-Compare the calculated size of batteries in submittal to actual ❑ ❑ ❑ <br /> batteries installed. <br /> 6. Ground Fault- Have the installer create a ground fault on the system,to ensure ❑ ❑ ❑ <br /> that the trouble condition and ground fault is annunciated on the FACP. <br /> 7. DACT- Have the alarm technician disconnect the primary line from the DACT to ❑ ❑ ❑ <br /> confirm a trouble signal on-site and transmission of a trouble signal to the <br /> supervision station within 4 minutes. Repeat this process with the secondary line. <br /> 8. Notification Appliance- Remove a wire from a notification appliance.The system ❑ ❑ ❑ <br /> shall go into trouble at the FACP within 200 seconds. <br /> 9. Smoke Detector- Remove a smoke detector from its base and ensure a trouble is ❑ ❑ ❑ <br /> shown on the panel within 200 seconds. <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 4.13.2020 I Page 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.