My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6500 MERRILL CREEK PKY BASE FILE 2024-03-01
>
Address Records
>
MERRILL CREEK PKY
>
6500
>
BASE FILE
>
6500 MERRILL CREEK PKY BASE FILE 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 10:43:21 AM
Creation date
2/18/2024 9:44:15 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6500
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. Documentation Cabinet-A documentation cabinet labeled "SYSTEM RECORD ❑ ❑ ❑ <br /> DOCUMENTS" shall be installed at the system control unit or at another approved <br /> location accessible only to authorized personnel. <br /> Step 3: Maximum Load Test - Secondary Power PASS FAIL N/A <br /> 1. Manual Fire Alarm box-While on battery power, initiate an Alarm by pulling the ❑ ❑ ❑ <br /> manual fire alarm box located at the FACP. <br /> 2. 90 Second Alarm Signal -Verify that the remote Central Station has received a fire ❑ ❑ ❑ <br /> alarm signal within ninety(90) seconds. Let alarm continue during next step. <br /> 3. 5 - 15 Minute Test- Let alarm continue for a minimum of 5 minutes for general ❑ ❑ ❑ <br /> occupant notification and 15 minutes for voice Evacuation.This is will give enough <br /> time to verify operation of all notification appliances throughout the facility. <br /> Audible Alarm Notification Appliances: <br /> PASS FAIL N/A <br /> 4. Per Plans-Verify annunciators are installed per approved plans ❑ ❑ ❑ <br /> 5. Audible Sound -Audible alarms devices must be 15 dBA above normal ambient ❑ ❑ ❑ <br /> sound level in all occupiable areas of building. <br /> 6. Signal Pattern -Audible signal pattern used to notify building occupants of the ❑ ❑ ❑ <br /> need to evacuate shall be the standard alarm evacuation signal consisting of a <br /> three-pulse temporal pattern. <br /> 7. Mounting-Wall-mounted appliances shall have their tops above the finished floor ❑ ❑ ❑ <br /> at heights of not less than 90 inches and below the finished ceilings at distances of <br /> not less than 6 inches. Ceiling-mounted or recessed appliances shall be permitted. <br /> 8. Combination Audible/Visible-Combination audible/visible appliances shall be ❑ ❑ ❑ <br /> installed as per the requirements for a visible alarm notification appliance. <br /> 9. Environment-Verify that all appliances as listed for the environment that they are ❑ ❑ ❑ <br /> located. (walk-in coolers/freezers, etc.) <br /> 10. Guards/Cover/Lenses-Appliances subject to mechanical damage shall be suitably ❑ ❑ ❑ <br /> protected by a guard, cover, or lenses that is listed for use with the appliance. <br /> Visible Alarm Notification Appliances: <br /> PASS FAIL N/A <br /> 11. Per Plans- Ensure the cd matches what was indicated on the plans. ❑ ❑ ❑ <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire INFORMATION HANDOUT C-5 4.13.2020 I Page 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.