Laserfiche WebLink
N111.Tf <br /> MATERIAL SPECIFICATIONS <br /> HDI-P TZ drop-in anchors are manufactured from carbon steel with zinc plating <br /> per DIN EN ISO 4042 A2K. <br /> INSTALLATION PARAMETERS <br /> Table 1 — Hilti HDI-P TZ setting information <br /> Nominal anchor size/internal thread dia.(in) <br /> Setting information Symbol Unit <br /> 3/8 <br /> Internal thread diameter d in. 3/8 <br /> Nominal bit diameter db;, in. 9/16 <br /> Nominal embedment hnom In. 3/4 <br /> (mm) (19) <br /> Hole depth in base material ho in. 3/4 <br /> (mm) (19) <br /> Effective embedment he, in. 3/4 <br /> (mm) (19) <br /> Thread engagement length ha in. 3/8 <br /> (mm) (10) <br /> Maximum installation torque for threaded element Tr„,, ft-lb 5TrTr„,, <br /> (N m) (7) <br /> Minimum base material thickness—concrete hm,,, in. 2-1/2 4 <br /> (mm) (64) (102) <br /> Minimum edge distance—concrete c,n,f in. 6 2-1/2 <br /> (mm) (152) (64) <br /> Minimum anchor spacing—concrete s,,,„ in. 8 3 <br /> (mm) (203) (76) <br /> Minimum base material thickness —hollow core concrete panels h„,, in. 1/3/8 <br /> ,, <br /> (mm) (35) <br /> Minimum edge distance—hollow core concrete panels C,n,n in. 6 <br /> (mm) (152) <br /> Minimum anchor spacing—hollow core concrete panels smin in. 8 <br /> (mm) (203) <br /> For SI:1 inch=25.4mm,1 ft-lb=1.356 Nm <br /> Figure 1 — Hilti HDI-P TZ installation parameters <br /> dbit <br /> L1- 1 <br /> gm - her hmin <br /> 4 :i hnom <br /> h9 ' -- -- <br /> I <br /> 430 Anchor Fastening Technical Guide Edition 21 13.0 ANCHORING SYSTEMS 13.3.13 HDI-P TZ FLUSH ANCHOR <br /> Hilti,Inc.1-800-879-8000 I en espanol 1-800-879-5000 I www.hilti.com I Hilti(Canada)Corporation I www.hilti.ca 11-800-363-4458 <br />