My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2024 12:23:23 PM
Creation date
2/24/2024 7:42:00 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUILT-IN CLASS A AND B CIRCUITRY POWER-LIMITED CIRCUITRY <br /> For the input and NAC circuits, the choice of Class A or All circuits are inherently power-limited. ARCs can be <br /> Class B supervision is made at site on the board itself by configured for power-limited or non-power-limited <br /> selecting the terminals used for wiring. Neither operation. One in-line releasing device is required for <br /> conversion boards nor additional hardware nor jumper each solenoid on a power limited ARC. In-line releasing <br /> selection is required for this purpose. devices are not included with the panel; the appropriate <br /> AGENT RELEASING CIRCUITS (ARC) number of in-line releasing devices should be ordered <br /> The two circuits can be programmed for activation by using part number 06-220023-001. <br /> different inputs, with independent time delays and abort ROBUST POWER SUPPLY UNIT(PSU) <br /> modes to fire combinations of two of the following The AEGIS 2.0 features a universal 120/240 V, 50/60 Hz <br /> releasing devices: AC Power Supply Unit with a robust 5.4 Amps of 24 VDC <br /> • 1 or 2 Kidde°, Fenwal°or Chemetron°Continuous power. Input voltage selection is via a slider switch with <br /> and Momentary Solenoid Control Heads no jumper cutting required. The on-board battery charger <br /> is able to charge 24 VDC (2 x 12) batteries of capacity up <br /> • 1 Kidde Actuator or Fenwal Initiators to 68 AH thereby allowing from 24 hours of supervision <br /> • 1 Factory Mutual Group A, B, D, E, F, G, I, J, or K plus 5 minutes of alarm to 90 hours of supervision plus 10 <br /> Solenoid minutes of alarm required by some jurisdictions. <br /> In other words, operating in tandem, the two circuits can AUXILIARY POWER SUPPLY <br /> release: Up to 1 Amp of auxiliary power at 24 VDC is available to <br /> • 1 or 2 Control Heads on ARC 1 and 1 or 2 Control power external 4-wire devices such as Flame Detectors, <br /> Heads on ARC 2 AlarmLine modules, Duct Detectors, etc. The auxiliary <br /> • 1 or 2 Control Heads on ARC 1 and 1 Actuator or power output is resettable. <br /> Initiators on ARC 2 or vice-versa ELEGANT USER INTERFACE <br /> • 1 or 2 Control Heads on ARC 1 and 1 FM Sprinkler <br /> Solenoid on ARC 2 or vice-versa The user interface consists of an array of LED Indicators, <br /> • 1 Actuator or Initiators on ARC 1 and 1 Actuator or Control Switches, a Digital Display, and Buzzer. Over and <br /> Initiators on ARC 2 above the System, Power Supply status, Input circuit Fire <br /> • 1 FM Solenoid on ARC 1 and 1 FM Solenoid on and Trouble and Output circuit Trouble LEDs, the AEGIS <br /> ARC 2 2.0 annunciates its suppression state-of-alarm via three <br /> This configurability is useful for those jurisdictions where additional Pre-Release, Releasing and Post Release <br /> the gaseous suppression agent is required to be LEDs. Four switches are provided, one each for <br /> supplemented with a pre-action system. Acknowledge, Signal Silence, System Reset and Output <br /> Disable. The 3-digit display provides a countdown of <br /> TRIPLE-R PROTECTION FOR ARCS impending agent release. On command from the user <br /> The two ARCs feature a triple failure redundancy interface switches, it also indicates the battery open <br /> safeguard system to protect them from inadvertent circuit voltage and charging current. <br /> activation. The Triple-R system requires that in order to SIMPLE SITE-SPECIFIC CONFIGURATION <br /> activate an ARC, the main microprocessor issues two <br /> release commands of opposing polarity via separate Setting the site-specific configuration is easily done using <br /> channels and that these commands be combined with a the digital display and user interface buttons. To prevent <br /> third signal from the panel watchdog timer to confirm the unauthorized use, the configuration menu is protected by <br /> auser-changeable password. Factory technical support <br /> microprocessor operation. The Triple-R system ensures <br /> that electrical transients or disturbances such as power can provide assistance with lost or forgotten passwords. <br /> surges that could interfere with the operation of the main Apart from the input voltage selection performed on both <br /> microprocessor will not inadvertently activate the the PSU and main board via a slider switch, no other un- <br /> connected suppression system. The result is a more board settings or jumper cuttings are required. <br /> robust and reliable suppression-focused panel. EXTENSIVE DIAGNOSTICS <br /> PROGRAMMABLE RELAYS Also initiated via the digital display and user interface <br /> Of the 4 relays, three are user-programmable for a variety switches, the troubleshooting function displays diagnostic <br /> of alarm related conditions and the fourth is a dedicated codes that assist in determining causes of trouble. A <br /> trouble relay. All relay contacts are rated 3.0 Amps at 30 complete list of diagnostic codes and their meaning ships <br /> VDC (resistive). factory installed on the inside of the enclosure door for <br /> easy reference. <br /> - 3 - <br />