My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2024 12:23:23 PM
Creation date
2/24/2024 7:42:00 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKWARDS COMPATIBILITY TECHNICAL SPECIFICATIONS (cont'd) <br /> The AEGIS 2.0 is backwards compatible and listed for One (1)Abort Circuit <br /> use with a full range of conventional detectors and alarm -Compatible with normally open contact-closure type <br /> devices as well as suppression accessories from Kidde, devices <br /> Fenwal and Chemetron. Going forward, this will allow - Configurable as Class A or Class B <br /> legacy panels to be replaced with relative ease. - Supervised for ground faults and open circuits <br /> EASY TO INSTALL CABINET - Six (6)Abort Modes available <br /> The cabinet design allows for easy installation by fitting - Power-limited <br /> between the studs of a standard 16 inch studded wall. It Two (2) Supervisory Circuits <br /> is large enough to house two 12 VDC, 12 AH Batteries -Compatible with normally open contact-closure type <br /> and provides up to 2 inches (51 mm) of wiring and finger devices <br /> space between the circuit board and the cabinet wall. - Configurable as Class A or Class B <br /> An optional door design features a Manual Release and - Option to use SUP 1 as fourth detection circuit <br /> Abort switch for applications with space constraints. Both - Supervised for ground faults and open circuits <br /> switches incorporate guards that prevent their - Power-limited <br /> inadvertent activation. Three (3) Notification Appliance Circuits (NACs) <br /> TECHNICAL SPECIFICATIONS -Compatible with polarized 24 VDC regulated Audio- <br /> Hazards Protected Visual devices <br /> • - Rated at 1.5 Amps each <br /> - One - Up to 35 synchronized appliances <br /> • Power Supply - Configurable as Class A or Class B <br /> - 120/240 V, 50/60 Hz (90 to 264 VAC, 47 to 63 Hz) - Supervised for ground faults, shorts, and open <br /> AC Main Input circuits <br /> -5.4 Amps at 27 VDC Output - Power-limited <br /> - Battery capacity up to 68 AH @ 24 VDC - Common NAC/ARC output disable switch <br /> -Auxiliary power output rated Class B at 1 Amp at Two (2) Agent Release Circuits <br /> 18.8 - 27.6 VDC (resettable) - Each compatible with 1 or 2 control heads, or 1 <br /> • Three (3) or Four(4) Detection Circuits actuator/initiator, or 1 FM sprinkler solenoid <br /> - Compatible with ESL/Interlogix 700 Series - Circuits electrically capable of simultaneously <br /> detectors, CPD-705x, PSD-715x, and THD-705x releasing any combination of two of the above <br /> detectors, as well as Normally Open contact devices <br /> closure type devices. Refer to documents K-70-100 - Factory configured as Class B <br /> and F-70-63 for details on compatibility and the - Supervised for ground faults and open circuits <br /> maximum number of devices supported. - Default setting: Power-Limited. Each solenoid on a <br /> - Configurable as Class A or Class B power-limited ARC requires the use of an in-line <br /> - Supervised for ground faults and open circuits releasing device, P/N 06-220023-001 (order <br /> - Power limited separately, not included with panel). <br /> - DET 1 and DET 2 used for suppression - Common NAC/ARC output disable switch <br /> - DET3/WF configurable for detection or waterflow Four(4) Relays <br /> - Option to use SUP 1 circuit as DET 4 circuit* - 3 independently programmable, normally de- <br /> • One (1) Manual Release Circuit energized Form-C Relays <br /> -Compatible with normally open contact-closure type - 1 dedicated normally energized Form-C Trouble <br /> devices Relay <br /> - Configurable as Class A or Class B - Relay contacts rated 3 Amps at 30 VDC (resistive) <br /> - Supervised for ground faults and open circuits <br /> - Power limited <br /> • Only contact-closure type, non-powered devices such as <br /> switches, pull stations and alarm contacts of 4-wire detectors <br /> to be used on this Detector 4 circuit. Powered 2-wire <br /> automatic detectors must not be connected to this circuit and <br /> the circuit must not be used to power 4-wire detectors. <br /> - 4 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.