mcl,
<br />5.
<br />N O
<br />aIT
<br />o 'm
<br />m
<br />3
<br />0
<br />w
<br />N
<br />N
<br />X X XX— rJ — —X 4RTE
<br />" GENERAL NOTES
<br />X—X I Xx X— X X X x X X-X—X X— X X 1. GENERAL: WORK SHALL BE DONE IN ACCORDANCE WITH CODES
<br />AS ADOPTED BY THE CITY OF EVERETT, SNOHOMISH COUNTY,
<br />AND THE STATE OF WASHINGTON.
<br />2. FIELD VERIFY EXISTING CONDITIONS, EQUIPMENT AND EQUIPMENT
<br />SIZES, PRIOR TO BID. EQUAL OR EXCEED EXISTING EQUIPMENT
<br />SIZES, RATINGS, ETC., FOR PROVIDED/INSTALLED MATERIALS.
<br />__3. LOCATIONS OF ELECTRICAL EQUIPMENT, DEVICES, LIGHTING
<br />+ + FIXTURES, ETC., INDICATED ON CIVIL / STRUCTURAL AND
<br />LANDSCAPE PLANS - INCLUDING SECTIONS, ELEVATIONS, NOTES,
<br />LIFT STATIOOR OTHER INDICATORS - TAKE PRECEDENCE OVER LOCATIONS
<br />PUMPS - SHOWN ON ELECTRICAL DRAWINGS.
<br />TYP OF 2SUTIL. XFMR 3x2 VA 4. REFER TO CIVIL, STRUCTURAL, LANDSCAPE, ETC., DRAWINGS FOR
<br />(256344, 3582 358264) UTIL. XFMR UTIL. XFMR WORK IN OTHER DIVISIONS. INFORMATION CONVEYED WITHIN THE
<br />XKVA 389614 XKVA 389614
<br />2'C TEL 2"C TEL ELECTRICAL DRAWINGS ILLUSTRATING OR REFERENCING WORK OF
<br />4 _ 76 I � - Is I OTHER DIVISIONS IS FOR REFERENCE ONLY. SPECIFICATION BY
<br />3 4 < - 10 THE RELEVANT DIVISIONS SHALL APPLY
<br />k _ - - - - - - I - - - _ - _ _ - - I - - - • 5. GENERAL NOTES ARE SHOWN ON SHEETS MOST RELEVANT TO
<br />SPECIFIC NOTE; HOWEVER, GENERAL NOTES ON EACH SHEET
<br />RP / - - - - _ _ - I - - - - - - - - - SHALL APPLY IN PRACTICE TO ALL ELECTRICAL DRAWINGS.
<br />6. NOT ALL COMPONENTS OF THE ELECTRICAL SYSTEMS ARE SHOWN
<br />D I I-7B-1y ¢jam/ a 2 1 // I T 7 8 \ I -7B-1 Z C{ P `V I (FOR SIMPLICITY). PROVIDE MATERIALS AND LABOR NECESSARY
<br />FOR A COMPLETE AND OPERATIONAL SYSTEM.
<br />7. LOCATIONS OF ELECTRICAL SYSTEMS COMPONENTS, INCLUDING
<br />2"C TEL may' / \ I - 2"C TEL / BUT NOT LIMITED TO, LUMINAIRES, DISTRIBUTION EQUIPMENT,
<br />/ 1 i II I CONDUIT, JUNCTION BOXES, VAULTS, ETC., MAY BE REVISED
<br />XX"C P TEL�� TQ1 XX"C P/ L TEL\ PRIOR TO CONSTRUCTION. CHANGES MADE BY THE OWNER IN
<br />�LIFT _ LOCATING ELECTRICAL COMPONENTS OF UP TO THIRTY FEET I CONT RACK I F\ I I HORIZONTALLY (AND/OR VERTICALLY) IS A PART OF THIS
<br />I I I CONTRACT. CHANGES IN LOCATION MAY BE IMPLEMENTED, AT
<br />I I NO CHARGE TO THE OWNER, WHEN MADE PRIOR TO ROUGH -IN
<br />I I I OF EQUIPMENT BEING RELOCATED.
<br />hl 0 9 0
<br />�+ o N 8. COORDINATE LOCATIONS OF ELECTRICAL AND COMMUNICATION
<br />+
<br />3 I r� CHASES AND CONDUITS WITH OTHER TRADES. ADJUST
<br />\ I LOCATIONS AS NECESSARY TO AVOID CONFLICTS.
<br />— MI — MI
<br />9. CONDUCTORS SHALL BE LABELED IN JUNCTION BOXES AND AT
<br />TERMINATIONS.
<br />10. COORDINATE INSTALLATION WITH SERVING UTILITIES; SNOHOMISH
<br />V II PUD. PROVIDE INFRASTRUCTURE IN COMPLIANCE WITH UTILITY
<br />I) I I) I COMPANYS CURRENT HANDBOOK, STANDARDS, AND POLICIES.
<br />II l I II l I THIS SCOPE OF WORK INCLUDES LABOR AND MATERIALS FOR
<br />REQUIRED COMPONENTS THAT ARE NOT PROVIDED BY THE PUD.
<br />J
<br />PROVIDE AS INDICATED ON DRAWINGS FOR CASES WHERE THE
<br />WORK SHOWN EXCEEDS MINIMUM UTILITY COMPANY
<br />REQUIREMENTS.
<br />11. SCOPE OF WORK, THIS SHEET, INCLUDES:
<br />11.1. REMOVE EXISTING LIFT STATION PUMPS AND CONTROLS.
<br />n RE -INSTALL REMOVED EQUIPMENT IN LOCATION SHOWN.
<br />I w I I N I RECONNECT ELECTRICAL SERVICE AND BRANCH CIRCUITS.
<br />I `" III I w II PROVIDE NEW CONDUIT AND WIRE;MATCH EXISTING TYPE(S).
<br />l I X— l ^I I X— 11.2. PERFORM WORK IN COORDINATION WITH SNOPUD. CONTACT,
<br />¢ ` ` SCHEDULE, AND SUPPORT, SNOPUD WORK SHOWN. PROVIDE
<br />r �\ �� MATERIALS, EXCAVATION, ETC., AS REQUIRED BY PUD.
<br />o o
<br />SHEET NOTES
<br />d I � x�x x d I � x�x x
<br />r I 1. REMOVE LIFT STATION SERVICE, SERVICE EQUIPMENT, BRANCH
<br />x x CIRCUITS, AND CONTROLS. SALVAGE/RETAIN FOR REINSTALLATION.
<br />b x I x I 2. DEMOLISH UNDERGROUND PRIMARY CONDUIT AND CONCRETE
<br />VAULT (AFTER PUD REMOVES PRIMARY CABLE) .
<br />MI x MI x
<br />ri 3. OVERHEAD AERIAL DEMOLITION BY PUD.
<br />5 _ _
<br />4. EXISTING PUD POLES; TO BE REMOVED BY PUD.
<br />x x
<br />iX X x _x_x x
<br />I E YPHONE I PAYPHONE 5. INSTALL LIFT STATION SERVICE EQUIPMENT. BASES AND
<br />SUPPORTS TO MATCH EXISTING INSTALLATION.
<br />i 7
<br />----1 Sa--- x 1 %----------
<br />I I � x----- 6. CONNECT BRANCH CIRCUITS TO RELOCATED PUMPS AND
<br />r \� ❑ ❑ i� I \� =E10
<br />��// I 7 CONTROLS.
<br />0 �ORIAL LINES BY PUD.
<br />z
<br />— x x
<br />.ri I 8. POLES AND POLE MOUNTED TRANSFORMERS BY PUD. CONDUIT
<br />C RISER(S) PER PUD STANDARDS.
<br />9. AERIAL LIGHT CIRCUIT RECONNECTED BY PUD.
<br />i
<br />10. PROVIDE UNDERGROUND SERVICE AND PUD RISER TO LIFT
<br />ELECTRICAL SITE PLAN - DEMOLITION ELECTRICAL SITE PLAN II STATION.
<br />SCALE IN FEET I V SCALE IN FEET I V
<br />n 20 0 20 40 I�t 20 0 20 40
<br />i IF THIS DRAWING IS NOT 22"04" SCALE ACCORDINGLY.
<br />PROJECT ENGINEER: SCALE: PORT OF EVERETT DWG. NO.
<br />PND ENGINEERS, INC. IS NOT RESPONSIBLE FOR SAFETY J E. DAVID NOTED E1.00
<br />TL PROGRAMS, METHODS OR PROCEDURES OF OPERATION, OR THE pF `97i
<br />Or ■ Of
<br />CONSTRUCTION OF THE DESIGN SHOWN ON THESE DRAWINGS. ./' DESIGNED BY: DATE: IyI I L LW R I G H T LOOP ROADS D S
<br />j v ® ® ® 3240 Eastlake A--E WHERE SPECIFICATIONS ARE GENERAL OR NOT CALLED OUT, E. DAVID JULY 2022 CIP NO.
<br />Smtde, W,shwgcon 98102 THE SPECIFICATIONS SHALL CONFORM TO STANDARDS OF 6-8-008-01
<br />EVERETT P:206.624.1387 INDUSTRY. DRAWINGS ARE FOR USE ON THIS PROJECT ONLY DRAWN BY CHECKED BY PHASE 1
<br />ENGINEERS, INC. w pndmgj,, e.aom AND ARE NOT INTENDED FOR REUSE WITHOUT WRITTEN J. CAMPBELL E. DAVID PROJECT PD-WP-2022-07
<br />P.O. BOX 538 APPROVAL FROM PND. DRAWINGS ARE ALSO NOT TO BE USED ELECTRICAL SITE PLAN NO.
<br />EVERETT, WA 98206 AO 7/27/2�EJYD ISSUED FOR BID IN ANY MANNER THAT WOULD CONSTITUTE A DETRIMENT APPROVED BY(425) 259-3164 DIRECTLY OR INDIRECTLY TO PND. 07/26/2022 1 3th STREET
<br />No. OATSREVISION SHEET NO. 47 OF 48