My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ordinance 4007-24
>
Ordinances
>
Ordinance 4007-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 1:45:49 PM
Creation date
2/29/2024 1:44:58 PM
Metadata
Fields
Template:
Ordinances
Ordinance Number
4007-24
Date
2/28/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
FIRE CODE ORDINANCE Page 20 of 38 <br /> <br />inches below the structural members and a maximum distance of 14 inches below the deck of the <br />exterior balconies and decks that are constructed open wood joist construction. <br /> <br />L. Subsection 903.3.1.3.1 of the IFC, entitled “NFPA 13D amendments,” is hereby added: <br /> <br />903.3.1.3.1 NFPA 13D amendments. A minimum of one head shall be installed on the garage side of <br />the door leading into the residence from an attached garage. <br /> <br />M. Subsection 903.4.2 of the IFC, entitled “Alarms,” is hereby deleted and the following inserted in its <br />place: <br /> <br />903.4.2 Sprinkler water flow notification. All fire sprinkler system installed in accordance with <br />903.3.1.1 or 903.3.1.2 shall be provided with occupant notification appliances that will automatically <br />activate throughout the notification zones upon a sprinkler water flow. <br /> Exception: NFPA 13D automatic sprinkler systems. <br /> <br />N. Subsection 903.4.2.1 of the IFC, entitled “Exterior horn and strobe,” is hereby added: <br /> <br />903.4.2.1 Exterior horn and strobe. A listed and approved horn and strobe device, located on the <br />front exterior of the building in an approved location and in close proximity to the buildings address, <br />shall be connected to each automatic sprinkler system to serve the function of alerting arriving first <br />responders of which building, or sprinkler system is in operation before staging firefighting activities. <br />Such sprinkler waterflow alarm device shall be activated by water flow equivalent to the flow of a <br />single sprinkler of the smallest orifice size installed, actuation of the automatic sprinkler system shall <br />actuate the building fire alarm system. <br /> <br />O. Subsection 904.13.5.1.1 of the IFC, entitled “Existing systems UL300 compliance.,” is hereby added: <br /> <br />904.13.5.1.1 Existing systems UL300 compliance. All existing dry-chemical and wet chemical <br />extinguishing systems within the City of Everett shall comply with UL 300. <br />EXCEPTION: Private and public-school kitchens, without deep-fat fryers, shall be upgraded to a UL <br />300 compliant system during modernizations projects or where changes in the cooking media, <br />positioning of cooking equipment or replacement of cooking equipment occur in existing <br />commercial cooking systems. <br /> <br />P. Subsection 904.13.5.4 of the IFC, entitled “Signage,” is hereby added: <br /> <br />904.13.5.4 Signage. When required by the fire code official, existing automatic fire-extinguishing <br />systems shall be provided with signage on the exhaust hood or system cabinet, indicating the type <br />of arrangement of cooking appliances protected by the automatic fire-extinguishing system. Signage <br />shall indicate appliances from left to right, be durable, and the size, color, and lettering shall be <br />approved. <br /> <br />Q. Subsection 907.2 of the IFC, entitled “Where required – new buildings and structures,” is hereby <br />deleted and the following inserted in its place: <br />
The URL can be used to link to this page
Your browser does not support the video tag.