My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2024-04-12
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2024-04-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2024 2:16:09 PM
Creation date
3/1/2024 9:56:00 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4" MIN SMOKE OR HEAT 3' MIN FROM 3' MIN FROM <br />FROM WALL DETECTORS DIFFUSER DIFFUSER <br />DO NOT <br />INSTALL V-0" MAX FROM CEILING OR <br />4" MIN HERE A/C SUPPLY OR RETURN DIFFUSER <br />FROM a NiH FROM CEILING STRUCTURE <br />12" MAX CEILING <br />FROM <br />CEILING SMOKE OR HEAT DETECTOR <br />99 CLEAN AGENT CEILING MOUNT VISUAL OR <br />f NOZZLE TYP. AUDIBLENISUAL DEVICE <br />L AUDIBLE <br />CONTROL DEVICE <br />PANEL <br />5' MAX DISPLAY <br />FROM <br />DOOR <br />90" MIN AFF <br />DOOR G <br />72" <br />8" 8, <br />MAX. <br />48" MAX MAINTENANCE BYPASS TYP. <br />AFF <br />ABORT STATION TYP. <br />MANUAL RELEASE STATION TYP. <br />NOTES: <br />• ALL ELEVATIONS ARE SHOWN FROM A VIEW OF BEING INSIDE THE ROOM LOOKING AT THE DOOR. <br />• ALL DEVICES SHALL BE MOUNTED IN ACCORDANCE WITH ALL APPLICABLE CODES. <br />• CONFER WITH THE LOCAL AHJ AND ENGINEER OF RECORD IF MOUNTING HEIGHTS CAN NOT BE ATTAINED OR CONFLICT WITH THE LOCAL CODES. <br />• ALL VISUAL DEVICES SHALL BE SYNCHRONIZED AND UNOBSTRUCTED. <br />• SOLENOID TO BE MOUNTED IN J/BOX AT CYLINDER VALVE OUTLET ELEVATION. <br />• MAINTENANCE BYPASS SHALL BE INSIDE PROTECTED HAZARD. <br />•• IF CYLINDER IS INSIDE PROTECTED HAZARD LOCATE AT CYLINDER. <br />•• IF CYLINDER IS OUTSIDE PROTECTED HAZARD LOCATE AT RELEASE PANEL NEAR MANUAL RELEASE AND ABORT STATION IN PROTECTED <br />HAZARD. <br />IF PANEL IS OUTSIDE PROTECTED HAZARD, LOCATE NEAR MANUAL RELEASE AND ABORT <br />ON IN <br />TECTED <br />• •• CONTROL UNIT DISPLAYS, VISIBLE INDICATORS, OR SHALL BE MOUNTED SUCH THAT THIE DISTANOCE TO THE HIGHEST SWITCH, LAMP, <br />OR TEXTUAL DISPLAY DOES NOT EXCEED 72" ABOVE THE FINISHED FLOOR AND THE LOWEST SWITCH, LAMP, OR TEXTUAL DISPLAY DOES NOT <br />EXCEED 15" ABOVE THE FINISHED FLOOR. <br />•• STANDARD REFERENCE NFPA 72 2019 EDITION (10.4.4) <br />• DISCHARGE STROBES TO BE MOUNTED ON THE OUTSIDE OF THE ROOM @ A MAX. OF 96" A.F.F. TO THE CENTER OF THE DEVICE. <br />• HORN/STROBES TO BE MOUNTED @ A MAX. OF 80" A.F.F. TO THE CENTER OF THE DEVICE PER ADA REQUIREMENTS. <br />• MANUAL RELEASE AND ABORT SWITCHES TO BE MOUNTED @ 48" A.F.F. TO THE TOP OF THE DEVICE. <br />• CLEAN AGENT DOOR SIGN IS TO BE MOUNTED ON THE OUTSIDE OF ALL DOORS TO CLEAN AGENT ZONES. <br />• CLEAN AGENT HORN/STROBE SIGN TO BE MOUNTED BELOW ALL SUPPRESSION HORN/STROBES IN A CLEAN AGENT ZONE. <br />• CLEAN AGENT DISCHARGE STROBE SIGNS TO BE MOUNTED BELOW ALL CLEAN AGENT STROBES. <br />SITE LOCATION <br />9 e <br />" <br />GOOgIerE"c V <br />B <br />Map data 02021 2000 h <br />..Ioft <br />Liiv <br />CEILING <br />LOW CEILINGS: <br />DEVICE SHALL BE <br />LOCATED WITHIN TOP OF STROBE LENS <br />6" OF THE CEILING VISUAL DEVICE <br />I <br />BOTTOM OF STROBE LENS <br />96" MAX <br />AFF <br />I <br />84" TYP <br />80" MIN <br />73.32" 1 AFF <br />CLEAN AGENT <br />CYLINDER TYP. <br />FINISHED FLOOR <br />STANDARD REFERENCE NOTES FOR AUDIO AND AUDIOVISUAL DEVICES: <br />• MOUNTING HEIGHTS FOR AUDIBLE APPLIANCES ARE DETERMINED BY THE FOLLOWING CODES: <br />•• NFPA 72 2019 EDITION (18.4.9.1) <br />• MOUNTING HEIGHTS FOR AUDIBLE/VISUAL APPLIANCES ARE DETERMINED BY THE FOLLOWING CODES: <br />NFPA 72 2019 EDITION (18.5.5.1) <br />STANDARD REFERENCE NOTES FOR DETECTION: <br />• MOUNTING HEIGHTS FOR MANUAL PULL STATIONS ARE DETERMINED BY THE FOLLOWING CODES: <br />• NFPA 72 2019 EDITION (17.15.6.5) <br />• • MOUNTING HEIGHTS FOR WALL MOUNTED SMOKE AND HEAT DETECTORS ARE DETERMINED BY THE FOLLOWING CODES: <br />•• NFPA 72 2019 EDITION (17.7.3.2.1 SMOKE AND 17.6.3.1.3.1 FOR HEAT) <br />GENERAL DEVICE ELEVATION <br />SUPIdESSION SYSTEMS INC. <br />SPECIAL HAZARDS FIRE PROTECTION <br />307 20TH STREET EAST, SUITE B <br />FIFE, WA 98424-1798 <br />TM (253) 9263300 FAX (25$)9263306 <br />LOGOS <br />fKidde <br />Fire Systems <br />PROTECTION ENGINEERS STAMP <br />COMPLIANCE <br />SUBMITTALS <br />DATE <br />100% SUBMITTAL <br />02/08/23 <br />REV <br />DESCRIPTION <br />DATE <br />QREVIEW <br />COMMENTS <br />02/17/23 <br />0 <br />0 <br />cl) <br />z <br />Q <br />w <br />J <br />U <br />O <br />CC <br />G <br />LU <br />C/) <br />z <br />N <br />00 <br />0) <br />< <br />L <br />Cc <br />IC <br />O <br />W <br />cr <br />(n <br />o <br />0 <br />U <br />IL <br />U <br />V <br />I <br />Z W <br />o z <br />W <br />u) <br />w <br />� <br />Lu Lu <br />~ <br />z <br />LU <br />o <br />Lu <br />H <br />cn <br />Fz <br />LU <br />W <br />cr <br />C) <br />o <br />cr <br />o <br />z Q <br />w <br />a N <br />UKLo <br />0 <br />Q <br />cNr)j <br />CD <br />DESIGNED BY: NMB <br />SCALE: <br />NOT TO <br />SCALE <br />UNLESS <br />NOTED <br />OTHERWISE <br />DRAWNBv: NMB <br />CHECI�D BV: ZST <br />JOB NUMBER: 23 66 <br />SHEET TITLE: <br />FIRE PROTECTION DRAWINGS <br />GENERAL ELEVATION <br />AND MAPS <br />SHEET NUMBER: <br />FP-02 of 07 <br />