My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2024-04-12
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2024-04-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2024 2:16:09 PM
Creation date
3/1/2024 9:56:00 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- 24'-0" <br />SUPIdESSION SYSTEMS INC. <br />SPECIAL HAZARDS FIRE PROTECTION <br />307 20TH STREET EAST, SUITE B <br />FIFE, WA 98424-1798 <br />TM (253) 9263300 FAX (25$)9263306 <br />EXISTING <br />VOLUME CALCULATION NOTES: <br />1. FORMULA FOR CALCULATIONS: <br />1.1. AREA x DEPTH = VOLUME <br />1.2. MINIMUM AMOUNT OF AGENT REQUIRED X ELEVATION CORRECTION = <br />ADJUSTED MINIMUM AGENT REQUIRED <br />2. NON -PERMEABLE VOLUME OF 45CF APPLIED. <br />3. FOR ADDITIONAL INFORMATION SEE THE CLEAN AGENT FLOW CALCULATIONS <br />INCLUDED IN THE SUBMITTAL PACKAGE. <br />4. AGENT DESIGN CONCENTRATION IS FROM NFPA 2001 AND MANUFACTURE <br />RECOMMENDATIONS. <br />ISOMETRIC PIPING NOTES: <br />5. PIPE LENGTH'S DO NOT REPRESENT CUT LENGTH'S. <br />6. ALL LENGTH'S SHALL BE FIELD VERIFIED. <br />7. ALL PIPING 1/2" TO 1 1/2" SHALL BE THREADED. MINIMUM AND MAXIMUM <br />PRESSURE RATINGS SHALL MEET FSSA PIPE DESIGN GUIDE FOR USE WITH <br />SPECIAL HAZARD FIRE SUPPRESSION SYSTEMS. <br />8. ALL PIPING 2" TO 6" SHALL BE GROOVED. MINIMUM AND MAXIMUM PRESSURE <br />RATINGS SHALL MEET FSSA PIPE DESIGN GUIDE FOR USE WITH SPECIAL <br />HAZARD FIRE SUPPRESSION SYSTEMS. <br />9. ANY DEVIATIONS IN PIPE LENGTH OR SIZE SHALL BE APPROVED BY <br />SUPPRESSION SYSTEMS INC. PRIOR TO BEGINNING INSTALLATION. <br />NAC 2 EOL <br />30cd - <br />NAC 1 EOL/COMBO 2 EO <br />O m NAC 2� 002 <br />1 <br />CONNECTTO <br />0 o NAC 2 <br />- <br />BUILDING <br />FACP <br />ERH930cd <br />BY SSI <br />N 7 O <br />L <br />000 <br />H <br />I Al 005 <br />I <br />--- Ab 006! <br />REL 1 I R JI <br />L <br />0 <br />N <br />II ❑4 3/4" X 2-0" <br />CAPACITOR STORAGE <br />CLEAN AGENT DETECTION AND <br />CONTROLS PLAN <br />SCALE: 1 /4" = V-0" <br />3/4" 90" NPT <br />TEE 3/4" NPT <br />UNION 3/4" NPT <br />REDUCE 2" X 3/4" NPT - <br />IN FROM 2" MANIFOLD ---- I <br />3/4" NPT TO SYSTEM PIPE <br />AND NOZZLES <br />REDUCER 3/4" X 1/2" NPT <br />1/2" 90° NPT <br />- UNION 1/2" NPT <br />DISCHARGE PRESSURE <br />SWITCH 1/2" NPT <br />L- 2" 90" <br />ADAPTER 2", BSP TO NPT <br />nFTAII "A" <br />B <br />3/4" X V-0"- <br />E1-N1 <br />38-407600-12� <br />E2-N1 <br />38-407500-045 <br />i <br />❑ <br />❑ <br />❑ <br />❑ i 1-1 1-1 <br />❑ <br />❑ <br />❑ <br />❑ - - <br />- <br />❑ <br />❑ <br />❑ <br />❑ - <br />❑ <br />❑ <br />❑ <br />❑ - - <br />❑ <br />❑ <br />❑ <br />❑ - <br />8'-0" <br />a <br />0 0� <br />O O <br />{L N <br />m <br />7 <br />cn <br />(VERIFY LOC-) <br />CAPACITOR STORAGE <br />CLEAN AGENT PIPING PLAN <br />C.H. 9-9 / SUB -FLOOR 1 -4 <br />SCALE: 1 /4"= V-0" <br />3/4" <br />I <br />3/4" DISCHARGE HOSE (TYP. 5) - <br />-3/4" X 1/2" REDUCER <br />1/2" X 10'-8" <br />CYLINDER VALVE AND <br />DISCHARGE HOSE SEE <br />ACTUATION DETAIL <br />- 3/4" 90° (TYP.2) <br />- 3/4" X S-6" <br />I <br />DETAIL "A" THIS SHEET <br />2" PRE -BUILT MANIFOLD <br />WITH 3/4" CHECK VALVES <br />PRE -INSTALLED <br />MANIFOLD END CAP <br />CLEAN AGENT AREA VOLUME CALCULATIONS <br />MINIMUM <br />ADJUSTED <br />AREA <br />DEPTH <br />VOLUME <br />AGENT <br />AGENT <br />AGENT <br />ELEVATION <br />MINIMUM <br />AGENT <br />CYLINDER <br />ROOM DESCRIPTION <br />(SQUARE FEET) <br />(FEET) <br />(CUBIC FEET) <br />CONCENTRATION <br />FACTOR <br />REQUIRES <br />CORRECTION <br />AGENT <br />SUPPLIED <br />SUPPLIED <br />(% BY VOLUME) <br />(POUNDS) <br />FACTOR <br />REQUIRED <br />(POUNDS) <br />(POUNDS) <br />CAPACITOR ROOM <br />480.0 <br />9-9" <br />4680 <br />46.90 <br />0.0461 <br />214.7 <br />214.7 <br />238.8 <br />CAPACITOR ROOM SUB -FLOOR <br />480.0 <br />V-4" <br />640 <br />46.90 <br />0.0461 <br />29.4 <br />29.4 <br />32.7 <br />TOTAL <br />-- <br />-- <br />-- <br />-- <br />-- <br />244.1 <br />244.1 <br />271.5 <br />5 - 80L <br />PRESSURE <br />RELIEF VENT (PRV) / EQUIVALENT LEAKAGE AREA (ELA) CALCULATIONS <br />CALCULATIONS PERFORMED BY KIDDE KFS HYDRAULIC FLOW SOFTWARE v4.00 <br />ESTIMATED FREE VENT AREA <br />AGENT SUPPLIED <br />AGENT <br />DISCHARGE TIME <br />VOLUME <br />MAXIMUM PRESSURE <br />REQUIRED <br />ROOM DESCRIPTION <br />POUNDS <br />(POUNDS) <br />CONCENTRATION <br />(SECONDS) <br />(CUBIC FEET) <br />(PSF) <br />(SQUARE FEET) <br />(0/6 BY VOLUME) <br />CAPACITOR ROOM & <br />271.5 <br />50.50 <br />113.5 <br />5320 <br />5.0 <br />0.90 <br />SUB -FLOOR <br />LOGO'S <br />fKidde <br />Fire Systems <br />PROTECTION ENGINEERS STAMP <br />COMPLIANCE <br />SUBMITTALS <br />DATE <br />100%SUBMITTAL <br />02/08/23 <br />REV <br />DESCRIPTION <br />DATE <br />QREVIEW <br />COMMENTS <br />02/17/23 <br />0 <br />0 <br />co <br />Z <br />Q <br />W <br />J <br />Ucn <br />0 <br />Q <br />cn <br />Z <br />o <br />col <br />00 <br />M <br />< <br />U <br />LU <br />Ir <br />0 <br />LU <br />w <br />cr <br />Fn <br />o <br />0 <br />U <br />IL <br />U <br />� <br />C'3 <br />Z W <br />o Z <br />W <br />w <br />W <br />W <br />Z <br />W <br />o <br />LU <br />H <br />07 <br />Fz <br />w <br />� <br />w <br />cr <br />o <br />o <br />Ir <br />o <br />z Q <br />w <br />a N <br />a <br />C3 <br />Q <br />c � <br />N <br />U7 <br />DESIGNED BY: NMB <br />SCALE- <br />OTT. <br />NOTTO <br />SCALE <br />UNLESS <br />NOTED <br />OTHERWISE <br />NMB <br />CHECI�D BV: ZST <br />JOB NUMBER: 2306 <br />SHEET TITLE: <br />FIRE PROTECTION DRAWINGS <br />FLOOR PLANS <br />AND ISOMETRICS <br />SHEET NUMBER: <br />FP-04 of 07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.