My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2024-04-12
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2024-04-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2024 2:16:09 PM
Creation date
3/1/2024 9:56:00 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUPIdESSION SYSTEMS INC. <br />SPECIAL HAZARDS FIRE PROTECTION <br />307 20TH STREET EAST, SUITE B <br />FIFE, WA 98424-1798 <br />TM (253) 9263300 FAX (25$)92"306 <br />AO RELAY MODULE <br />Al MONITOR MODULE <br />DETECTOR BASE <br />O q <br />MABLE <br />TROUBLE <br />RELAY <br />120 VAC, 50/60 Hz, 3.2 A WHITE <br />or BLACK <br />240 VAC, 50/60 Hz, 1.6 A GREEN <br />SOLENOID ) <br />BLK RED <br />10K IN -LINE RELEASING DEVICE (LOCATE <br />AS CLOSE AS POSSIBLE TO SOLENOID) <br />J <br />®® <br />TB1 TB1 <br />C J <br />M""" `6 + ® O O <br />R"— <br />P P P[n <br />O ACP 13 O SYSTE-IJELE ACKNC'*LEDSE O SILENCE O <br />O ALARM Q SUPDMSCRY <br />SYSTEM SCROLL <br />O PREAIARM O SILENCE RESET <br />fKidde 0 0 0 0 0 E <br />Fire Systems 0 0 0 0 0 <br />SWITCH (S2) <br />Om <br />AC SUPPLY SELECT SWITCH (S4) <br />T62 AUXILIARY OUTPUTS <br />REGULATED 24 VDC, <br />CURRENT: 1.0 (MAX) EACH OUTPUT <br />A/B <br />TB12 T611 OOO TB2 TB7 <br />rEEI rEEIE ®® <br />H G G <br />POWER SUPPLY: <br />RELAYS (POWER OR NON -POWER LIMITED BUT NOT BOTH): <br />**5 AMP MAXIMUM ALL EXTERNAL DEVICES** <br />TB #4, TB #8, TB #9 - PROGRAMMABLE RELAY SPDT FORM C <br />NOTE: EXTERNAL DEVICES INCLUDE ALL NOTIFICATION APPLIANCES, CONTACT <br />RELEASING SOLENOIDS, SLC INITIATING AND CONTROL DEVICES <br />RATED FOR 1.0 AMPS @ 30 VDC (RESTRICTIVE) <br />AND ALL DEVICES POWERED FROM THE PANEL POWER SUPPLY. <br />RATED FOR 0.5 AMPS @ 30 VDC (INDUCTIVE) <br />TB #13 - AC/DC POWER SUPPLY UNIT <br />RATED FOR 0.5 AMPS @ 120 VDC (INDUCTIVE) <br />5.4 A @ 27VDC <br />TB #10 - TROUBLE RELAY SPDT FORM C CONTACT <br />120 OR 240 VAC <br />RATED FOR 1.0 AMPS @ 30 VDC (RESTRICTIVE) <br />50/60 Hz LINE VOLTAGE <br />RATED FOR 0.5 AMPS @ 30 VDC (INDUCTIVE) <br />NON -POWER LIMITED <br />RATED FOR 0.5 AMPS @ 120 VDC (INDUCTIVE) <br />TB #3 - BATTERY CONNECTION <br />SUPERVISED <br />AUXILIARY POWER: <br />24 VDC NOMINAL <br />TB #2 - RESETABLE 24VDC POWER OUTPUT <br />MAX. BATTERY SIZE 70 AH <br />POWER LIMITED AND SUPERVISED <br />NON -POWER LIMITED - DEDICATED CIRCUIT <br />1 AMP MAXIMUM EACH CIRCUIT <br />**5 AMP MAXIMUM ALL EXTERNAL DEVICES** <br />NOTE: EXTERNAL DEVICES INCLUDE ALL NOTIFICATION APPLIANCES, <br />RELEASING SOLENOIDS, SLC INITIATING AND CONTROL <br />DEVICES AND ALL DEVICES POWERED FROM THE 24 Vdc POWER <br />SUPPLY. <br />TB6 <br />14 <br />0 <br />SIGNALING LINE CIRCUIT (SLC): <br />TB #1 SIGNALING LINE CIRCUIT WIRING REQUIREMENTS <br />POWER LIMITED AND SUPERVISED <br />UP TO 255 ADDRESSABLE DEVICES <br />CLASS "B" STYLE 4 <br />(CLASS "A" CONDUIT SEPARATION SHALL BE MAINTAINED AT A <br />MINIMUM <br />OF 1 FOOT VERTICALLY AND 4 FEET HORIZONTALLY. NFPA 72 <br />CHAPTER 6 <br />CLASS "A" STYLE 6 <br />CLASS "A" STYLE 7 USING ISOLATOR DEVICES <br />350MA MAX / 28VDC MAX / 40 OHMS MAX / 20Pf PER FOOT <br />TWISTED, UNSHIELDED, LOW -CAPACITANCE, <br />ADDRESSABLE -FIRE ALARM WIRE <br />ARIES-SLX TYPICAL WIRING DIAGRAM <br />10k EOL <br />POLARIZED NOTIFICATION <br />APPLIANCE (TYPICAL) <br />POLARIZED NOTIFICATION <br />APPLIANCE (TYPICAL) <br />NOTIFICATION APPLIANCE CIRCUITS (NAC) AND RELEASING <br />CIRCUITS: <br />TB #5 AND TB #14 NAC CIRCUITS <br />POWER LIMITED AND SUPERVISED <br />NOT "T" TAPPABLE <br />REGULATED 24VDC, 1.5 AMPS MAX PER CIRCUIT <br />CLASS "B" STYLE "Y" / CLASS "A" STYLE "Z" <br />MAXIMUM # SYNCHRONIZED DEVICES PER CIRCUIT IS 25 <br />TB # 11 AND TB #12 RELEASING CIRCUITS <br />SERIES WIRED INITIATOR ASSEMBLIES <br />SINGLE CONTROL HEAD OR SOLENOID VALVE <br />TWO SERIES -SUPERVISED, PARALLEL -ACTUATED <br />CONTROL HEADS OR SOLENOID VALVES <br />MAX RELEASE CURRENT 2.4 AMPS PER CIRCUIT <br />TB #6 AND TB #7 COMBINATION CIRCUITS <br />PROGRAMMED AS NAC CIRCUITS FUNCTION THE SAME AS <br />ABOVE <br />PROGRAMMED AS RELEASE CIRCUITS CAN SUPPORT ONE <br />CONTROL HEAD OR ONE PRE -ACTION SOLENOID <br />LOGO'S <br />fKidde <br />Fire Systems <br />PROTECTION ENGINEERS STAMP <br />COMPLIANCE <br />SUBMITTALS <br />DATE <br />100% SUBMITTAL <br />02/08/23 <br />REV <br />DESCRIPTION <br />DATE <br />QREVIEW <br />COMMENTS <br />02/17/23 <br />0 <br />ZL <br />0 <br />cl) <br />Z <br />Q <br />W <br />J <br />U <br />O <br />O <br />C/) <br />Z <br />o <br />N <br />00 <br />0) <br />L <br />Lu <br />Ir <br />O <br />> <br />w <br />cr <br />c/) <br />O <br />O <br />U <br />IL <br />U <br />� <br />(D <br />Z W <br />o Z <br />2 W <br />w <br />W <br />ILL. <br />Lu <br />W <br />Z <br />W <br />o <br />LU <br />H <br />cn <br />Fz <br />w <br />� <br />w <br />cr <br />o <br />C) <br />cr <br />EE <br />o <br />z <br />w <br />a N <br />a <br />( <br />N <br />CD <br />LO <br />DESIGNED BY: NMB <br />SCALE: <br />NOT TO <br />SCALE <br />UNLESS <br />NOTED <br />OTHERWISE <br />DRAWNBY: NMB <br />CHECKED BY: ZST <br />JOB NUMBER: 2306 <br />SHEET TITLE: <br />FIRE PROTECTION DRAWINGS <br />ELECTRICAL DETAILS <br />MULTI -LINE WIRING DIAGRAM <br />SHEET NUMBER: <br />FP-05 of 07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.