My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6920 SEAWAY BLVD 2023 Plans 2024-03-07
>
Address Records
>
SEAWAY BLVD
>
6920
>
Plans
>
6920 SEAWAY BLVD 2023 Plans 2024-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2024 2:04:39 PM
Creation date
3/7/2024 2:04:25 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6920
Permit
M2301-077
Year
2023
Notes
REPLACE (1) WATER COOLED CHILLER WITH NEW
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
33 h <br /> W C 01 <br /> c <br /> g 3 E <br /> a a <br /> . a. e• <br /> Q U \`1 <br /> 6: <br /> PROJECT OVERVIEW LEGAL DESCRIPTION o Q o0 ' <br /> p o = <br /> •COORDINATE SITE LAY DOWN AREA WITH OWNERS REPRESENTATIVE. SEC 11 TP 28 RGE 04 ALL TH PTN N1/2 NW1/4 SEC 11&S1/2 SW 1/4 SEC 2-28-4 p o J W Lu <br /> LY SLY&WLYOFFDL-COMATSECOROFNE1/4NW1/4 SEC 11THN88'03 0>c, Co 2 .4+ I +� <br /> •INSTALL ACCESS DOOR IN OUTSIDE WALL TO ALLOW CHILLER TO BE REMOVED AND NEW 53W ALG S LN SD SUB 40FT TO POB TH N00'30 25E 139FT TO BEG OF CRV TO W Cl-m rn >- J tII ku <br /> ONE INSTALLED. L HAVG RAD OF 660FT TH NLY ALG SD CRV THRU 2'}Q ^ a Q <br /> Y 0.2 i� 3 <br /> •DECOMMISSION EXISTING CHILLER. �I �� 7 U¢ O uai NO W uj <br /> •REFRIGERANT SHALL BE REMOVED FROM CHILLER BY FLUKE PERSONNEL AND STORED ��- J Y o q O u++ w 2 - u o <br /> FOR FUTURE USE. ; k.,,,Q °� IL J > cN � = = ,,,-.;• a a <br /> ro C) IL c0 w C l0 c.c.. L.L 0 w tl) <br /> ct cc <br /> •REMOVE AND DISPOSE OF CHILLER,CHILLED WATER PUMP,AND MOTORS PER APPLICABLE V <br /> REGULATIONS. WORK THIS f m N <br /> +- <br /> •REPLACE CHILLED WATER PUMP WITH NEW EQUIVALENT UNIT AND CONNECT TO NEW VFD PERMIT �� o m in <br /> (VARIABLE FREQUENCY DRIVE). a o 4t Q O <br /> y f0 CD U <br /> •REMOVE CONDENSER WATER PUMP MOTOR,REPLACE WITH VFD COMPATIBLE MOTOR, O. v o, Q v c 0 0 -- 3 <br /> AND CONNECT NEW MOTOR TO NEW VFD. 4', p C Q U y 0 <br /> ® v 3 aci a ) > <br /> •REMOVE COOLING TOWER FAN MOTOR,REPLACE WITH VFD COMPATIBLE MOTOR,AND ) o`_ tl 0 I- Q d G �' <br /> CONNECT NEW MOTOR TO NEW VFD. - fa 0 , g ,_ <br /> a <br /> •INSTALL TEE'S IN CHILLED WATER SUPPLY AND RETURN PIPING,ISOLATION VALVES,BLIND � <br /> FLANGES,AND EXTEND TO OUTSIDE WALL FOR FUTURE USE. SEE PAGE 9,ITEM 9.OF THE \ 1 y <br /> DESIGN CRITERIA FOR MORE INFORMATION. - d <br /> ++ Z <br /> •INSTALL OUTSIDE AIR LOUVER,MOTORIZED DAMPER,HOOD,REFRIGERANT MONITOR, <br /> BEACONS/STROBE 5,AND EMERGENCY CHILLER SHUT DOWN. 1I�N <br /> © VICINITY MAP a <br /> •REMOVE AND REPLACE OR UPDATE EXISTING MECHANICAL ROOM EXHAUST FAN TO MEET SCALE:NTS III <br /> F ., I <br /> CRITERIA STATED ON THE DRAWINGS. sell> '> <br /> -•I O <br /> •CONFIGURE NEW CHILLER CONTROLS TO MEET WASHINGTON STATE ENERGY CODE. SEE 1 N m d <br /> DRAWING M4&M5. MECHANICAL ROOM I' �� 1 (q .o j n C <br /> LOCATION ' ' \ s�N o ¢N E <br /> •ADD TEMPERATURE SENSORS AND FLOW SWITCHES IN CHILLED AND CONDENSER WATER ` • w s¢m v a <br /> PIPING AS SHOWN ON DRAWING M4. ° ; . `�\ • . ;�p� 0 3? <br /> •MONITOR CERTAIN OPERATING PARAMETERS OF THE NEW CHILLER AND COMMUNICATE a o z N <br /> THE INFORMATION VIA THE EXISTING BAS(BUILDING AUTOMATION SYSTEM). /`. •`;�♦;q` ° ' o No w e a W <br /> NOTE: THIS DOCUMENT IS INTENDED AS AN OVERVIEW AND DOES NOT NECESSARILY �♦♦�< . Loa <br /> CONTAIN ALL ITEMS REQUIRED TO COMPLETE THIS PROJECT. ._�..�-```� \ W c <br /> 2 O I- <br /> N- ►r_� Ir* > f- m U � <br /> �► I��i( t / o o N W Q <br /> �AgAr rvi ►ids U U U N <br /> ��_ � O 2 O g N O CULL <br /> E _ 1 amz <br /> © KEY PLAN 1 . ` . ° a..Z <br /> SYMBOLS ABBREVIATIONS SCALE:NTS ,2J Q g <br /> w En- <br /> o E <br /> BAS BUILDING AUTOMATION SYSTEM o <br /> BUTTERFLY VALVE DRAWING INDEX 1- <br /> 0 U <br /> CCP CHILLER CONTROL PANEL M1 COVER SHEET D 2 N w . E <br /> CR CONDENSER WATER RETURN M2 MECHANICAL ROOM PLAN AND SCHEDULES vca <br /> ILJ4 TEMPERATURE TRANSMITTER U Z <br /> OR FLOW SWITCH M3 CHILLER ROOM EMERGENCY VENTILATION w < ‘- Additional PermRs Are Required <br /> CWR CHILLER WATER RETURN w a N <br /> M4 DIAGRAM AND SOO a U U 0 For This Project To Include. <br /> CWS CHILLER WATER SUPPLY `o <br /> NEW WORK M5 DCC POINT LISTS 1 <br /> FS FLOW SWITCH Scale ❑ Plumbin <br /> AS NOTED g ❑ Sprinkler <br /> SOO SEQUENCE OF OPERATION yv M. <br /> EXISTING WORK or Sheet ❑ Mechanical ® Fire Alarm <br /> Tr TEMPERATURE TRANSMITTER S . M S 5 <br /> of <br /> VFD VARIABLE FREQUENCY DRIVE s <br /> ' ' -� J�[�I Electrical <br /> Sz !JL <br /> ' : € "Y OF EVERETT <br /> MAR 0 6 2023 REVIEWED FOR PERMIT <br /> r CITY OF EVERETT <br /> Permit Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.