6920 SEAWAY BLVD 2023 Plans 2024-03-07
>
Address Records
>
SEAWAY BLVD
>
6920
>
Plans
>
6920 SEAWAY BLVD 2023 Plans 2024-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2024 2:04:39 PM
Creation date
3/7/2024 2:04:25 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6920
Permit
M2301-077
Year
2023
Notes
REPLACE (1) WATER COOLED CHILLER WITH NEW
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s. <br /> OUTLINE OF EXISTING Z <br /> FIRE PROTECTION CHILLER SCHEDULE <br /> 0OUTLINE OF HEADER TO REMAIN <br /> F- <br /> SERICEACCESS <br /> REQUIRED TONS 250 go 0 <br /> a n r-- ________' <br /> Imo` i j b__________ ____ OJ W <br /> OUTLINE OF NEW 1 S"` VOLTAGE 480 (,(� �m <br /> CHILLER \ ``.�1 „ RLA 215 SC O a <br /> \\\ CHILLED WATER FLOW(GPM) 598.9 J w w r <br /> OUTLINE OF EXHAUST CHILLED WATER PRESSURE DROP(FT) 15.9 1 0o w <br /> SERVICE ACCESS — Ja <br /> GRILLE <br /> REQUIRED SEE M-3 CONDENSER WATER FLOW(GPM) 705.4 v u-ID W <br /> CONDENSER WATER PRESSURE DROP <br /> (FT) 9.7 m <br /> IPLV(kW/TON) 0.316 a A <br /> EXISTING CHILLED AND <br /> CONDENSER WATER FULL LOAD KW/TON 0.602 m <br /> PUMPS TO BE UPGRADED I`� 1 <br /> %n '1 -g <br /> L o0 <br /> Rm' I <br /> N <br /> O <br /> z <br /> NI N <br /> 14° 0 <br /> mI 3 .e <br /> EXISTING CHILLED J o <br /> AND CONDENSER O <br /> WATER PIPING U1 g <br /> TO BE EXTENDED ,'tn p>,-N <br /> TO NEW CHILLER W c v <br /> MECHANICAL ROOM PLAN i,� 0 <br /> �Ci 0 >o Oko <br /> SCALE:3/16"=1._0. in <br /> d N K <br /> . <br /> Q o> <br /> wd <br /> Chilled Water Pump:Replace existing pump <br /> with new pump and inverter duty motor with <br /> VFD. <br /> 1. Pump Flow Rate:770 gpm m d N <br /> 2. Pump Head:85 ft o 2 o <br /> 3. Motor:25 hp,non-overloading pump a; L ;; m <br /> 4. Motor Speed:1800 rpm 0 o •• <br /> 5. Impeller Diameter:10.75 in o o a ci o <br /> 6. Fluid:Water,45 deg F <br /> 7. Weight:693 lbs <br /> 8. Electric Service:208-230/460 3 phase,60Hz 06 U) <br /> 9. Basis of Design:B&G,Series e-1510,Model 4EB 0 a) <br /> 10.Basis of Design VFD:ABB ACH580 or Owner approved 0 <br /> manufacturer. Z a) <br /> 11.11.Modify existing concrete pad as required. d Ill o <br /> j 2 Cl) <br /> Condenser Water Pump:Replace existing motor only and w U 2 <br /> provide new inverter duty motor and cc <br /> VFD.Existing pump to remain. ti -I a d c <br /> 1. Existing Pump Information for Reference: o I LU E 13 <br /> Paco 11-50957-746L01,930 GPM at 60 Feet of a U d <br /> Head.20 HP motor-1800 RPM.Motor Frame 256T, Scale <br /> Insulation Class F,208-230/460 3 phase, t AS NOTED <br /> 60Hz 1.15 SF,TEFC. m++•c <br /> 2. Provide new VFD ABB ACH580 or Owner approved c,�f Sheet <br /> manufacturer. E M`L of 5 <br /> 3. Modify existing concrete pad as required. <br /> • e <br /> Apr, <br /> ��ITY OF EVERETT <br /> REVIEWED FOR PERMIT <br />