My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1502 WALNUT ST A B 2024-05-03
>
Address Records
>
WALNUT ST
>
1502
>
1502 WALNUT ST A B 2024-05-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2024 1:55:50 PM
Creation date
3/18/2024 2:47:05 PM
Metadata
Fields
Template:
Address Document
Street Name
WALNUT ST
Street Number
1502
Unit
A B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> • • <br /> TABLE 406.3 <br /> ENERGY CREDITS <br /> CREDIT(S) <br /> OPTION DESCRIPTION <br /> All Other Group R-2 <br /> I1.EFFICIENT BUILDING ENVELOPE OPTIONS <br /> Only one option from Items 1.1 through 1.7 may be selected in this category. <br /> Compliance with the conductive UA targets is demonstrated using Section R402.1.4,Total UA alternative,where <br /> [1-(Proposed UA/Target UA)]>the required%UA reduction <br /> Prescriptive compliance is based on Table R402.1.1 with the following 0.5 <br /> modifications: <br /> Vertical fenestration U=0.24. <br /> 1.2 Prescriptive compliance is based on Table R402.1.1 with the following 1.0 1.0 <br /> modifications: <br /> Vertical fenestration U=0.20. <br /> 1.3 i Prescriptive compliance is based on Table R402.1.1 with the following 0.5 N/A <br /> modifications: <br /> Vertical fenestration U=0.28 <br /> Floor R-38 <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4:Reduce the Total conductive UA i <br /> by 5%. <br /> 1.4 Prescriptive compliance is based on Table R402.1.1 with the following 1.0 . t0 <br /> modifications: <br /> Vertical fenestration U=0.25 <br /> Wail R-21 plus R-4 ci <br /> Floor R-38 <br /> Basement wall R-21 int plus R-5 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4:Reduce the Total conductive UA <br /> by 15%. <br /> 1.5 Prescriptive compliance is based on Table R402.1.1 with the following 2.0 E 1.5 <br /> modifications: <br /> Vertical fenestration U=0.22 <br /> Ceiling and single-rafter or joist-vaulted R-49 advanced <br /> • Wood frame wall R-21 int plus R-12 ci <br /> Floor R-38 <br /> Basement wall R-21 int plus R-12 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or • <br /> Compliance based on Section R402.1.4:Reduce the Total conductive UA <br /> by 30%. <br /> RE-42 201$Washington State Energy Code <br />
The URL can be used to link to this page
Your browser does not support the video tag.