Laserfiche WebLink
, . <br /> . ... , ' <br /> 1 17-7.'" • , z ll F-----; 7 L <br /> r <br /> , ,, .. ...: , , .. ..,, , CIEOVE <br /> OCT 0 s 2022 <br /> _I <br /> 14 „ <br /> MAR 0 3 2023 <br /> ,_. <br /> . Li CITY OF EVERETT <br /> CITY 0 EYPRETT Permit Services <br /> 17 <br /> Fei.m;t El,o- i-f!:-...'.,:-.. ECTION R406 <br /> ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS <br /> R406.1 Scope.This section establishes additional energy efficiency requirements for all new construction i <br /> covered by this code,including additions subject to Section R502 and change of occupancy or use • <br /> subject to Section R505 unless specifically exempted in Section R406.Credit from both Sections R406.2 <br /> • and R406.3 are required. <br /> R406.2 Carbon emission equalization.This section establishes a base equalization between fuels used i <br /> to define the equivalent carbon emissions of the options specified.The permit shall define the base fuel <br /> selection to be used and the points specified in Table R406.2 shall be used to modify the requirements in <br /> Section R406.3.The sum of credits from Tables R406.2 and R406.3 shall meet the requirements of <br /> Section R406.3. <br /> R406.3 Additional energy efficiency requirements.Each dwelling unit in a residential building shall <br /> comply with sufficient options from Table R406.2 so as to achieve the following minimum number of <br /> credits: <br /> 1. Small Dwelling Unit: 3.0 credits <br /> Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of <br /> fenestration area.Additions to existing building greater than 500 square feet of heated floor area but <br /> less than 1500 square feet. <br /> 2. Medium Dwelling Unit: 6.0 credits <br /> All dwelling units that are not included in#1,#3 or#4. <br /> 3. Large Dwelling Unit: 7.0 credits <br /> Dwelling units exceeding 5000 square feet of conditioned floor area. <br /> 4. Dwelling units serving R-2 occupancies: .4.5 credits <br /> 5. Additions less than or equal to 500 square feet. 1 5 credits <br /> The drawings included with the building permit application shall identify which options have been <br /> selected and the point value of each option,regardless of whether separate mechanical,plumbing, <br /> electrical,or other permits are utilized for the project. <br /> TABLE R496.2 <br /> FUEL NORMALIZATION CREDITS <br /> I Credits II <br /> System ' Description of Primary Heating Source <br /> Type 1 Ail Other I Group R-2 . <br /> i 1 <br /> 1 Combustion heating equipment meeting minimum : 0 ' 0 • <br /> federal efficiency standards for the equipment • <br /> • <br /> listed in Table C403.3.2(4)or C403.3.2(5) • <br /> • <br /> 'I <br /> 2 : For an initial heating system using a heat pump 1-0 1.0 • <br /> • <br /> that meets federal standards for the equipment , • <br /> listed in Table C403.3.2(1)C or C403.3.2(2) • <br /> • <br /> , • <br /> or , • <br /> • <br /> Air to water heat pump units that are configured to , • <br /> • <br /> 1 ' provide both heating and cooling and are rated in • <br /> accordance with Al-iRI 550/590 • <br /> • <br /> • I-- I <br /> 3 ' For heating system based on electric resistance -1-0 -1.0 . <br /> only(either forced air or Zonal) • <br /> 4 For heating system based on electric resistance 0.5 N/A <br /> with a ductless mini-split heat pump system in , <br /> accordance with Section R403.7.1 including the <br /> exception <br /> 1 5 All other heating systems -1 -0.5 : <br /> • <br /> 2018 Washington State Energy Code RE-41 <br /> , . <br />