My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2501 HOYT AVE 2025-04-15
>
Address Records
>
HOYT AVE
>
2501
>
2501 HOYT AVE 2025-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2025 1:51:31 PM
Creation date
3/20/2024 8:50:55 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2501
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LIMITATIONS • USG Securock Gypsum-Fiber Roof Board is engineered to perform within a properly designed roof <br /> system.The use of USG Securock Gypsum-Fiber Roof Board as a roofing component is the <br /> responsibility of the design professional. <br /> • Consult roofing manufacturers for specific instructions on the application of their products to <br /> USG Securock Gypsum-Fiber Roof Board.For fully adhered fiberglass reinforced membranes <br /> consult the membrane manufacturer. <br /> • Weather conditions,dew,application temperature,installation techniques and moisture drive <br /> can have adverse effects on the performance of the roof system and are beyond the control <br /> of USG. <br /> • Keep USG Securock Gypsum-Fiber Roof Board panels dry before,during and after installation. <br /> USG Securock Gypsum-Fiber Roof Board should not be installed during rain,heavy fog and any <br /> other conditions that deposit moisture on the surface of the board.Apply only as much USG <br /> Securock Gypsum-Fiber Roof Board that can be covered by final roof membrane system in the <br /> same day.Avoid exposure to moisture from leaks or condensation. <br /> • Wind uplift(vertical pull)of the roof system as installed can be affected by many factors beyond <br /> USG's control,including moisture migrating into the roof assembly from inside or outside the <br /> building,proper fastener spacing,the quality of installation especially for fasteners and whether <br /> the framing has been properly designed and installed to meet strength and deflection criteria <br /> specified in the contract documents.For all these reasons,USG cannot guarantee the wind-uplift <br /> resistance(vertical pull)of any roof assembly or system containing USG roof boards. <br /> • Moisture from inside the building can be as big a risk for the roof system as moisture from outside. <br /> The contractor installing the roof and the design professional should protect the <br /> roof assembly not only from excessive moisture during the construction of the building(new <br /> concrete,paint,plaster materials)but also after the building is dried in.The HVAC system must <br /> properly manage moisture generated by the occupants of the building to make sure it is vented to <br /> the outside and does not migrate into the roof system. <br /> • Panel spacing may be needed based on factors like roof deck's size,membrane color,ultimate <br /> deck surface temperature and time of year the roof is installed.The designer of record should use <br /> USG's published physical properties below to determine if spacing is needed. <br /> • For reroof or re-cover applications,existing roofing system must be dry throughout prior to <br /> application of USG Securock Gypsum-Fiber Roof Board. <br /> • Plastic or poly packaging applied at the plant to protect board during rail or other transit should <br /> be removed upon receipt to prevent condensation or trapping of moisture,which may cause <br /> application problems. <br /> • USG Securock Gypsum-Fiber Roof Board should be stored flat and off the ground with protection <br /> from the weather.If stored outdoors,a breathable waterproof covering should be used. <br /> • When applying solvent-based adhesives or primers,allow sufficient time for the solvent to <br /> evaporate to avoid damage to roofing components. <br /> • USG allows the bonding of cold mastic-modified bitumen,low rise urethane foam and torching <br /> directly to the surface.Consult with the system manufacturer for recommendation on <br /> these applications. <br /> • USG recommends maximum asphalt application temperature for Type III or Type IV asphalt of 455° <br /> F when using USG Securock Gypsum-Fiber Roof Board.Application temperatures above these <br /> recommended temperatures may adversely affect roof system performance. <br /> FIRE PERFORMANCE • UL Classified(Type FRX-G)as to Surface Burning Characteristics in accordance with ASTM E84 <br /> (CAN/ULC-S102). <br /> —Flame Spread 5 and Smoke Developed 0 <br /> • 1/4",3/8",1/2"and 5/8"thickness—Class A in accordance with UL790(CAN/ULC-S107). <br /> See the UL Building Materials Directory for more information. <br /> • 5/8"thickness—Meets requirements of Type X per ASTM C1278 and may be used in P series <br /> designs as a thermal barrier. <br /> SYSTEM PERFORMANCE • FM Approved <br /> —Complies with requirements of FM 4450 and FM 4470 <br /> —Meets FM Class 1 <br /> STANDARDS COMPLIANCE USG Securock Gypsum-Fiber Roof Board is manufactured to conform to ASTM C1278,"Standard <br /> Specification for Fiber-Reinforced Gypsum Panel." <br /> C 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.