PHYSICAL PROPERTIES 1/4"(6.3mm) 3/8"(9.5mm) 1/2"(12.7mm) 5/8"(15.9mm)
<br /> Width,standard 4'(1,219 mm) 4'(1,219 mm) 4'(1,219 mm) 4'(1,219 mm)
<br /> Length,standard 4'(1,219 mm)and 4'(1,219 mm)and 4'(1,219 mm)and 4'(1,219 mm)and
<br /> 8'(2,438 mm) 8'(2,438 mm) 8'(2,438 mm) 8'(2,438 mm)
<br /> Pieces per unit for 4'x 8'sheets 50 40 30 24
<br /> Weight,nominal lb./unit,4'x 8'sheet 2,575 2,575 2,725 2,525
<br /> Weight,nominal lb./sq.ft. 1.57 1.96 2.76 3.20
<br /> Flexural strength,parallel,lb.min., 40 70 110 161
<br /> per ASTM C473
<br /> Compressive strength,psi nominal 1,800(12.4MPa) 1,800(12.4MPa) 1,800(12.4MPa) 1,800(12.4MPa)
<br /> Flute spanabiiity per ASTM E661 2-5/8" 5" 8" 10"
<br /> Permeance,perms,per ASTM E96 30 26 26 24
<br /> R Value per ASTM 018 0.2 0.3 0.5 0.6
<br /> Coefficient of thermal expansion, 8.0x104 8.0x104 8.0x104 8.0x104
<br /> inches/inch•°F,per ASTM E831
<br /> Linear variation with change in moisture, 8.0x104 8.0x10-6 8.0x104 8.0x104
<br /> Inches/Inch•%RH,per ASTM 01037
<br /> Water absorption,%max,per ASTM C473 10 10 10 10
<br /> Surface water absorption,nominal grams, 1.6 1.6 1.6 1.6
<br /> per ASTM C473
<br /> Mold resistance per ASTM D3273' 10 10 10 10
<br /> Bending radius 25' 25' 25' 30'
<br /> 'ASTM D3273 Mold Resistance Testing:In independent tab tests conducted on USG Securock°Brand Gypsum-Fiber Roof Board
<br /> and USG Securock°Brand Ultralight Glass-Mat Roof Board at the time of manufacture per ASTM D3273 Standard Test Method
<br /> for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber,both panels scored a 10.The
<br /> ASTM lab test may not accurately represent the mold performance of building materials in actual use.Given unsuitable project
<br /> conditions during storage,installation or after completion,any building material can be overwhelmed by mold.To manage the
<br /> growth of mold,the best and most cost-effective strategy is to protect building products from water exposure during storage and
<br /> installation and after completion of the building.This can be accomplished by using good design and construction practices.
<br /> SUBMITTAL APPROVALS Job Name
<br /> Contractor Date
<br /> I _
<br /> PRODUCT INFORMATION
<br /> See usg.com for the most up-to-date product information.
<br /> CAUTION
<br /> Dust may cause irritation to eyes,skin,nose,throat,and
<br /> upper respiratory tract.Cut and trim with a utility knife
<br /> or hand saw to minimize dust levels.Power tools must be
<br /> equipped with a dust collection system.Wear eye,skin,and
<br /> respiratory protection if necessary.If eye contact occurs,
<br /> flush thoroughly with water for 15 minutes.If irritation
<br /> persists,call physician.Do not swallow.If swallowed,call
<br /> physician.For more information call Product Safety:
<br /> 800 507-8899 or see the SDS at usg.com
<br /> KEEP OUT OF REACH OF CHILDREN.
<br /> TRADEMARKS
<br /> The trademarks USG,SECUROCK,IT'S YOUR WORLD.
<br /> BUILD IT.,the USG logo,the design elements and colors,
<br /> and related marks are trademarks of USG Corporation or
<br /> its affiliates.
<br /> NOTE
<br /> Products described here may not be available in all
<br /> geographic markets.Consult your USG Company sales
<br /> office or representative for information.
<br /> NOTICE
<br /> We shall not be liable for incidental and consequential
<br /> damages,directly or indirectly sustained,nor for any loss
<br /> caused by application of these goods not in accordance with
<br /> current printed instructions or for other than the intended
<br /> use.Our liability is expressly limited to replacement of
<br /> defective goods.Any claim shall be deemed waived unless 800 USG.4YOU
<br /> made in writing to us within thirty(30)days from date it 800(874-4968)
<br /> was or reasonably should have been discovered. usg.com
<br /> SAFETY FIRST!
<br /> Follinstalltiond. safety/iessaryi precautions
<br /> andicesd eg Manufacturedds by 0
<br /> USG Corev.poation ���
<br /> installation.Take necessary precautions and wear the United States Gypsum Company ©2020 USG Corporation and/
<br /> appropriate personal protective equipment as needed.Read 550 West Adams Street or its affiliates.All rights
<br /> %.
<br /> SOS and literature before specification and installation. Chicago,IL 60661 reserved.Printed in USA IT'S YOUR WORLD.BUILD IT.°
<br /> Io1 21
<br />
|