My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2022 BLDG 40-30 Plans 2024-03-28
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-30
>
Plans
>
3003 W CASINO RD 2022 BLDG 40-30 Plans 2024-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2024 1:07:28 PM
Creation date
3/27/2024 10:43:58 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-30
Permit
FA2205-003
Year
2022
Notes
REPLACE SPRINKLER MONITORING PANEL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> SEE SHEET EOa FOR LEGEND AND ABBREVIATIONS <br /> A <br /> Point <br /> FA Device Number Number/Zone Boeing Description to `' Motes t? <br /> 1:07 128 SV31-4 TAMPER OS&Y Sprinkler Valve - 40-30-TNE263 J.2/12.2 TUNNEL SYSTEM SEQUENCE OF OPERATION <br /> 1:08 129 SV31-4 WF PRESSURE Waterflow Pressure Switch with Delay 1 E260 A/12 <br /> 1:09 12F SV31-4 WF ISO TAMPER Waterflow Isolation Tamper Switch 1 E260 A/12 1. ALARM CONDITION: <br /> 1:10 12B SV31-6 TAMPER OS&Y Sprinkler Valve 40-30-TNE263 J.2/12.3 TUNNEL <br /> 1:11 12C SV31-6 WF PRESSURE Waterflow Pressure Switch with Delay 1 E260 A/12 1.1 ACTIVATION OF ANY ALARM SHALL CAUSE THE FOLLOWING: <br /> 1:12 12D SV31-6 WF ISO TAMPER Waterflow Isolation Tamper Switch 1 E260 AM a. Alarm indicator LED on FACP to illuminate. GENERAL NOTES <br /> 1:13 12E SV31-8 TAMPER OS&Y Sprinkler Valve 40-30-TNE264 J.2/14.1 TUNNEL b. FACP Internal Sounder to activate. <br /> 1:14 130 SV31-8 WF PRESSURE Waterflow Pressure Switch with Delay 1E261 A/14 c. Display proper message on FACP to display ALARM POINT LOCATION INFORMATION. <br /> 1:15 131 SV31-8 WF ISO TAMPER Waterflow Isolation Tamper Switch 1E261 A/14 Of. Activate FACP DACT, transmit ALARM signal to Central Station monitoring company. <br /> 1:16 132 SV31-10 TAMPER OS&Y Sprinkler Valve 40-30-TNE264 J.2/14.2 TUNNEL <br /> 1:17 133 SV31-10 WF PRESSURE Waterflow Pressure Switch with Delay 1E261 A/14 2. SUPERVISORY CONDITION: <br /> 1:18 134 SV31-10 WF ISO TAMPER Waterflow Isolation Tamper Switch 1E261 A/14 2.1 ACTIVATION OF ANY SUPERVISORY CONDITION SHALL CAUSE THE FOLLOWING: <br /> 1:19 135 SV31-12 TAMPER OS&Y Sprinkler Valve 40-30-TNE265 J.2/15.2 TUNNEL <br /> 1:20 136 SV31-12 WF PRESSURE Waterflow Pressure Switch with Delay 1E262 A/15 a. Supervisory indicator LED on FACP to illuminate. <br /> 1:21 137 SV31-12 WF ISO TAMPER Waterflow Isolation Tamper Switch 1E262 A/15 b. FACP Internal Sounder to activate. <br /> 1:22 138 SV31-14 TAMPER OS&Y Sprinkler Valve 40-30-TNE265 J.2/17 TUNNEL c. Display proper message on FACP to display SUPERVISORY POINT LOCATION INFORMATION. <br /> 1:23 139 SV31-14 WF PRESSURE Waterflow Pressure Switch with Delay 1E262 A/17 d. Activate FACP DACT, transmit SUPERVISORY signal to Central Station monitoring company. <br /> 1:24 13F SV31-14 WF ISO TAMPER Waterflow Isolation Tamper Switch 1 E262 A/17 <br /> 1:25 13B SMK @ FACP 1E261 A.5/13 3. TROUBLE CONDITION: <br /> 1:26 13C MAN PULL @ FACP 1E261 A.5/13 3.1 ACTIVATION OF ANY TROUBLE CONDITION SHALL CAUSE THE FOLLOWING: <br /> 1:01 122 SMK ELEV 1 1ST FLR Update field/programming description E506-3 A/13 a. Trouble indicator LED on FACP to illuminate. <br /> 1:02 123 SMK ELEV 1 2ND FLR ION Update field/programming description E506-3 AM b. FACP Internal Sounder to activate. REFERENCE DRAWINGS <br /> 1:03 124 SMK ELEV 1 3RD FLR ION Update field/programming description E506-3 A/13 <br /> c. Display proper message on FACP to display TROUBLE CONDITION. <br /> 1:04 125 SMK ELEV 1 CATWALK jUpdate field/programming description E506-3 A/13 d. Activate FACP DACT, transmit TROUBLE signal to Central Station monitoring company. <br /> 1:05 126 SMK ELEV 1 TOP OF SHAFT jUpdate field/programming description E506-3 A/13 <br /> 1:06 127 SMK ELEV 1 MACH RM jUpdate field/programming description E506-3 A/13 <br /> 40-31 EAST BUILDING FACP POINTS LIST FIRE ALARM SYSTEM SEQUENCE OF OPERATION <br /> SCALE: NONE E506-4 SCALE: NONE E506-4 <br /> CONSTRUCTION NOTES <br /> ARIES NETLINK POWER SUPPLY AND BATTERY SIZE CALCULATION - 40-30/31 BUILDING <br /> TOTAL STAND-BY CURRENT PER SYSTEM: 0.353 AMPS <br /> TOTAL ALARM CURRENT PER SYSTEM: 0.530 AMPS <br /> ENTER STAND-BY HOURS: 48 HOURS <br /> ENTER ALARM TIME: 10 MINUTES <br /> AMPERE HOUR REQUIRED: 17.06 AH <br /> TOTAL AMP HOUR REQUIRE(DERATING FACTOR 1.2): 21.00 AH <br /> BATTERY SIZE REQUIRED PER SYSTEM (TWO(2) BATTERIES REQUIRED): 21 AH <br /> BILL OF MATERIALS 2-TIERED MAIN OR EXPANSION ENCLOSURE,MAX.20 AMPS* 15 AMPS <br /> EXPANSION ENCLOSURE(S)REQUIRED? YES <br /> Part# Item Description Unit Qty. NUMBER OF ENCLOSURE(MAIN/EXPANSION) REQUIRED: 1 <br /> NUMBER OF POWER MANAGEMENT UNIT(PMU) BOARD REQUIRED: 1 <br /> 76-800015-001 ARIES NETLink Multi-Loop DACT Card. ea 1 NUMBER OF POWER SUPPLY UNIT(PSU)REQUIRED: 1 <br /> 84-330002-001 PULL STATION-ADDRESSABLE ea 1 <br /> DS-PS PHOTO DETECTOR ea 1 TOTAL TOTAL <br /> REM STANDBY STANDBY ALARM ALARM <br /> DS-SB STANDARD BASE FOR DS SERIES DETECTORS ea 1 1 MOB(WIT ON QTY (AMPS) (1583) (AMPS) (AMPS) <br /> 1 CB WffH KEYBOARD/DISPLAY) 1 0.15830 0.15830 0.30000 0.30000 <br /> 70-417018-001 ADDRESSABLE CONTACT INPUT DEVICE ea 119 2 DIGITAL ALARM COMMUNICATOR TRANSMITTER(DACT)EXPANSION CARD 1 0,02400 0.02400 0.03700 0.03700 <br /> SLA1146 12V 24AH Batteryea 2 3 REMOTE DISPLAY CONTROL MODULE(RDCM) 1 .090000 0.09000 0.09100 0.09100 <br /> 4 SMARTONE PHOTOELECTRIC SMOKE DETECTOR DS-PS 7 0.00015 0.00105 0.00022 0.00154 <br /> 06-SS000689-1 RECORD STORAGE CABINET ea 1 s SMART0"CONTACT INPUT MODULE(AI's,N/0) zo 0.00058 0.01160 0.00058 0.01160 <br /> 1000015.00000 SSU-00500-BATTERY CABINET ea 1 6 POWER MANAGEMENT UNIT(PMU)BOARD#11,MAX. 10.6 AMPS , 0.07000 0:07000 0.os000 0.09000 <br /> TOTALS <br /> BILL OF MATERIALS 2 <br /> SCALE: NONE FIRE ALARM CONTROL PANEL BATTERY CALCULATIONS <br /> E506-4 <br /> � SCALE: NONE E50`6-4 <br /> WE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br /> ACCEPTABILITY W DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 12.28.21 THIS DESIGN AND OR FIRE ALARM SYSTEM DETAILS B 04.07.22 <br /> SPECIFICATION IS AP RDVED ENGINEERSHEET SEQUENCE NO. <br /> B SHOP DRAWINGS AGOW/HG 04.07.22 BOE//V6 APPROVED BY DEPT. DATE � EVERETT FIRE PANEL REPLACEMENT E506 <br /> ,!T°L-"AH BUILDING 40-031 <br /> APPROVED a, ELECTRICAL MASTER EVERETT, WA. DV10"o' 40-031-E506-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.