3003 W CASINO RD 2022 BLDG 40-30 Plans 2024-03-28
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-30
>
Plans
>
3003 W CASINO RD 2022 BLDG 40-30 Plans 2024-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2024 1:07:28 PM
Creation date
3/27/2024 10:43:58 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-30
Permit
FA2205-003
Year
2022
Notes
REPLACE SPRINKLER MONITORING PANEL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
*SPRINKLER VALVE WATERFLOW ALARM LEGEND <br /> MONITORING AND WATERFLOW ISOLATION SEE SHEET EOa FOR LEGEND AND ABBREVIATIONS <br /> TO SPRINKLERS _ SUPERVISION EQUIPMENT INSTALLATION A <br /> r WATERFLOW <br /> 7r <br /> PRESSURE SWITCH <br /> WITH BUILT—IN <br /> RETARD/DELAY, I A <br /> POTTER #WFSR—F <br /> (ALARM) <br /> I , I GENERAL NOTES <br /> I <br /> 1. ELECTRICAL CONTRACTOR SHALL INSTALL ENCLOSURE(S) <br /> r J AND POWER. <br /> TO WATER <br /> —I I MOTOR GONG 2. SPRINKLER RISER PIPING CONFIGURATION SHOWN IS <br /> WATER PRESSURE GAUGE J — — — ANY SPECIFIC AND <br /> DDOES NOT NECESSARILY REPRESENT <br /> (SYSTEM PRESSURE) ALARM LINE g WATERFLOW <br /> (ISOLATION ISOLATION <br /> (OPEN) VALVE, TAMPER SWITCH, <br /> APOLLO POTTER #REVS <br /> #94A-103-27 (SUPERVISORY) <br /> BY—PASS LINE L — — F__ — — — <br /> REFERENCE DRAWINGS <br /> RETARD <br /> CHECK VALVE o <br /> DRAIN CHECK <br /> CHAMBER <br /> I <br /> WATER PRESSURE GAUGE . VALVE <br /> (SUPPLY PRESSURE) OPEN (CLOSED) A <br /> OS&Y TAMPER ANALOG PHONE LINE (PRIMARY) CONSTRUCTION NOTES <br /> SWITCH WATER BY—PASS TEST <br /> (SUPERVISORY) STRAINER FIRE ALARM 1. ALL WIRING SHALL BE DRESSED AND TRAINED IN A <br /> VALVE (CLOSED) DRIP CONTROL *TELCO <br /> CUP PANEL DEMARC MONITORED BY TYCO AND WORKMANLIKE MANNER. <br /> 1111 FACP SIGNAL SENT TO CENTRAL <br /> BOEING FIRE DEPARTMENT 2. ALL WIRES SHALL BE LABELED WITH WIRE ID. <br /> ANALOG PHONE UNE (SECONDARY) 3. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> FIRE ALARM CABLING <br /> 4. ALL PENETRATIONS TO FIRE ALARM CONTROL PANEL <br /> CONTROLPUL STA ONWATER CODE, <br /> VALVEN) f ISMOKE T SEPARATE SHOWN.PATHWAYS FOR SIGNAL REQUIRED BY AND TELECOMMUNICATIONS ENCLOSURES SHALL BE IN <br /> CHECK FLOW & TAMPER ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br /> VALVE SWITCHES *BOEING SERVICES REQUEST MUST BE MADE B�> PROVIDE PHENOLIC LABELS, INSTALL AND CENTER ON <br /> REQUESTING: TWO ANALOG VOICE (BUSINESS FLAT LINE) UPPER ENCLOSURE DOOR WITH FACP AND POWER <br /> ®4 HORNS, BELLS JACK/CONNECTIONS. AFTER JACKS ARE INSTALLED, CIRCUIT IDENTIFICATIONS. LABELS SHALL HAVE WHITE <br /> DRAIN & STROBES ANALOG LINES MUST BE REQUESTED TO CONNECT LETTERING AND RED BACKGROUND. <br /> WATER SUPPLY PIPE ANALOG VOICE JACKS. <br /> © CONFIGURE FIRE ALARM CONTROL PANEL TO TRANSMIT <br /> PRIMARY AND SECONDARY COMMUNICATIONS IN A <br /> *NOTE: SIMULTANEOUS MANNER IN ACCORDANCE WITH <br /> LIMIT OF ONE (1) ISOLATION NFPA72-2016 26.6.4.1.4(B)(7). <br /> VALVE ON ALARM SENSING LINE. <br /> SPRINKLER RISER WATERFLOW PRESSURE SWITCH W/DELAY DETAIL FIRE ALARM SYSTEM SIGNAL AND COMMUNICATIONS OVERVIEW PROVIDE CONDUIT WITH PULLSTRING. <br /> SCALE: NONE E506-1 <br /> SCALE: NONE E506-1 ® PROVIDE LINE SIZE BALL VALVE WITH LOCKABLE <br /> HANDLE, TYPE AS NOTED, ON ALARM LINE UPSTREAM <br /> OF ALARM SWITCH. FIELD VERIFY CORRECT SIZE. <br /> PROVIDE TAMPER SWITCH, TYPE AS NOTED, ON <br /> ISOLATION VALVE AS SHOWN. <br /> PROVIDE WATERFLOW PRESSURE SWITCH WITH <br /> A A ADJUSTABLE DELAY, TYPE AS NOTED. <br /> 11. CONFIRM ONLY ONE (1) ISOLATION VALVE IS INSTALLED <br /> ON WATERFLOW SENSING LINE. WHERE EXISTING <br /> 6 6 INSTALLATIONS HAVE MORE THAN ONE (1) VALVE, <br /> COORDINATE REMOVAL OF ADDITIONAL VALVE(S) WITH <br /> 5 5 BOEING CONSTRUCTION MANAGER. <br /> 12"X12" PHONE J—BOX 12"X12" PHONE J—BOX 12. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> FACP EVT—FA-40-31 FOR PRIMARY AND FACP EVT—FA-40-30/31 FOR PRIMARY AND PRIMARY CONNECTION:Q INSTALLATION OF DEVICES AND PIPING MODIFICATIONS. <br /> (EXISTING ELEVATOR 1 FACP ® C.5/13) SECONDARY PHONE :BA <br /> :DEAR <br /> ION:Q (EXISTING ELEVATOR 4 FACP ® A.5/13.3) SECONDARY PHONE <br /> LINE JACKSELEPHONE LINE JACKS PHONE LINE <br /> (BY ELECTRICALARC. (BY ELECTRICAL <br /> CONTRACTOR) ING IT) CONTRACTOR) (CABLING BY BOEING IT) <br /> ECTION:Q SECONDARY CONNECTION:ELEPHONE PHONE LINE TO TELEPHONE <br /> RC. BACKBOARD/DEMARC. <br /> ING IT) (CABLING BY BOEING IT) <br /> FIRE ALARM SYSTEM COMMUNICATIONS DETAIL KT� FIRE ALARM SYSTEM COMMUNICATIONS DETAIL /-4� <br /> SCALE: NONE E506-1 SCALE: NONE E506-1 <br /> O� <br /> 5yM REVISION BY APPROVED DATE SYM REVLSWN By APPROVED DATE ACCEPTABILITY RAWN DATE SUBTITLE FIRE ALARM SYSTEM DETAILS B CURRENT REVISION SYMBOL DATE <br /> THIS DESIGN AND/OR <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 12.28.21 B SPECIFICATION IS APPROVED SHEET SEQUENCEE O. <br /> 22 <br /> NN0. <br /> B SHOP DRAWINGS AGOW/HG 04.07.22 �J BOE/NL/ m APPROM BY DEPT. DATE TIS EVEFIRE PANEL REPLACEMENT E506-1 <br /> BUILDING 40-031 <br /> A <br /> owc No <br /> ELECTRICAL MASTER EVERETT, WA. . 40-031—E506-1 <br />