• <br /> Wiring & Configuration • <br /> Signature device loop Auxiliary&smoke power outputs(TB3) <br /> The system provides one Signature device loop circuit with a total The control panel provides two auxiliary power TB3 <br /> capacity of 125 detectors and 125 module addresses.The loop outputs that can be used for powering ancillary 0 _t—NO <br /> circuit is supervised for opens,shorts,and grounds. equipment such as remote annunciators and two <br /> (1)wire smoke detectors. Aux 2 can be software 7 NC <br /> Circuit i01000 i064 selected to operate continuously.The circuit is 't- <br /> specifications <br /> Device loops One Class B or A One Class B or A loop, supervised for shorts and grounds. (2) 0 —t—NO <br /> loop,supporting 125 supporting 64 devices of Circuit specifications 0 T <br /> detectors and 125 any kind. Circuit voltage 21.9 to 28.3 V <br /> modules.Expandable to range 0 1 NC <br /> four loops. Resettable circuit 24 VDC nominal at 500 mA (3) + <br /> Communication Maximum 20 V peak-to-peak (Aux power 2) NO <br /> line voltage 0 T <br /> Circuit current 0.5 A max Continuous circuit 24 VDC nominal at 500 mA. <br /> Circuit 66f1 total,0.5 pF,max (Aux power 1) Use this circuit for powering 0 <br /> two-wire smoke detectors. <br /> impedance (4) <br /> Isolators 64 maximum Note:Any current above 0.5 amp connected to both Aux <br /> 1 and 2 will reduce the total available NAC power by that 0 <br /> Signal Supported on a system-wide basis(all device loops) amount. <br /> Synchronization when using a SIGA-CC1 S or SIGA-MCC1 S module (1)Trouble <br /> and Genesis or Enhanced Integrity notification supervisory ap Alarm,trouble,and la <br /> pliances. relay(TB3 <br /> ) (2)Supervisory <br /> The trouble relay is normally-open,held closed, <br /> (3)Alarm <br /> ce;Bwwing :bsAwiring and opens on any trouble event or when the <br /> panel is de-energized.The supervisory relay is (a)Smoke/Aux <br /> SLC A ,m Daa una SLC A :.01 normally-open,and closes on any supervisory <br /> SLC B �)( + SLC B ;01.1ismI � event.The alarm relay changes over on any <br /> e alarm event. <br /> I.00P loop Laap Loop <br /> Loop Carddam. daNioe Lay cam pat,une dame device <br /> Relay specifications <br /> Alarm 1 Trouble Supervisory <br /> Type Form C Form A <br /> Notification appliance circuits(TB2) Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive - <br /> i01000 control panels come equipped with four notification ap Relay circuits can only be connected to power limited sources. <br /> pliance circuits.i064 control panels come with two NACs.Each <br /> circuit can be individually configured for continuous,temporal, <br /> synchronized,and coded output. <br /> Annunciator loop(TB4) <br /> Specifications i01000 1064 The control panel provides a connection for up to eight serially <br /> Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A driven and supervised remote annunciators. <br /> with SA-CLA module <br /> Voltage 24 VFWR Circuit specifications <br /> Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Device loops Class B(Style Y)or Class A(Style Z) <br /> per circuit at 120/230 per circuit at 120/230 Circuit voltage 2.55 V <br /> VAC 60 Hz. VAC 60 Hz. Circuit current 30 mA max <br /> 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. Circuit Up to 8 annunciators or 4000 feet <br /> per circuit at 230 VAC per circuit at 230 VAC impedance <br /> 50 Hz. 50 Hz. <br /> Impedance 26 fl total,0.35 µF max Class B Class A <br /> EOLR 15 K fl,'/2 W Dii1 Ciarml 2 CMand 1 Etsmal2 <br /> Synchronization Supported system-wide + — + — + — + — <br /> I(S) COSI 1` IS)IGIISI&184 <br /> Cbs B Wing Char Awing <br /> 7 m NA I- + + (Mi Mil{+,1 CH1 N <br /> wiCl• .N.N �' 0 NACI, a Vtrn /�Itt.}11 L��N <br /> 0 NAC2- EOLR © NAC2- + r /J �� `7r ` <br /> "C2. .BJH�. U NAC2. - I _ <f <br /> T62 Tgq 00112(+)N Q Dtf 2(+)NI <br /> rwca- ®' �� ' 0- 0012H■ C}Q(-)H <br /> 0 NACa- EOLR <br /> TB6 766 <br /> Marking indicates output signal polarity when the circuit is active.Polarity reverses <br /> when the circuit is not active.Wire notification appliances accordingly.Notification <br /> appliance polarity shown in active state. <br /> Page4of8 IA1 A `,fll [ 1 E85001-0135 <br /> Pint to be tot(d for insl.,lldtion pot1,,):rs. Issue 1.5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.