My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5010 VIEW DR 2024-04-12
>
Address Records
>
VIEW DR
>
5010
>
5010 VIEW DR 2024-04-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2024 9:03:41 AM
Creation date
3/27/2024 11:15:48 AM
Metadata
Fields
Template:
Address Document
Street Name
VIEW DR
Street Number
5010
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Option Cards 0 • <br /> EDWARDS iO Series panels are supported by a complete line RZI16-2 Remote Zone intillgIMIIII <br /> of modules and related equipment that enhance performance ,.._,..,-- <br /> and extend system capabilities.Option cards plug directly into• , ® M-41414,1 <br /> the control panel main circuit board or are connected to it with a ®;14 <br /> ribbon cable.After installation,terminals remain accessible.The ' ', <br /> cabinet provides ample room for wire routing,keeping wiring neat i ' t 1_ <br /> at all times. t i' ..� ,- <br /> �•. j, . <br /> 1, <br /> ' ,Z <br /> Single and Dual Loop Controller Cards <br /> The i0-SDC1 is a single loop controller card that can be used with The RZI16 2 Addressable Remote Zone Interface Module is an <br /> the i064 as a replacement for the standard 64-point loop,or with addressable device that provides connections for sixteen Class B <br /> the i01000 as a 250 point expansion module. Initiating Device Circuits and two Class B Supervised Output <br /> Circuits.The inputs and outputs can be configured individually <br /> The i0-SDC2 is a 500-point dual loop controller card for the for several device types. <br /> i01000 that provides two SLC circuits,each with 125 detector <br /> addresses and 125 module addresses. It requires 18 consecutive addresses on the Signaling Line Circuit <br /> (SLC).Addresses are assigned electronically.There are no address <br /> Specifications iO-SDC1 i0-SDC2 switches to set. <br /> Device Addresses 01000:one loop,250 i01000:two loops, The RZI16-2 incorporates two 8-segment DIP switches that <br /> device addresses 500 device addresses are used to select the Alarm or Supervisory default device type <br /> i064:64 addresses for each of the 16 IDC circuits.The module also includes one <br /> Wiring Class B or Class A 4-segment DIP switch used to select the default Relay or NAC <br /> Operating Voltage 24VDC output device type.Device types other than the default are <br /> Operating Current Standby:55 mA Standby:45 mA accomplished through programming. <br /> (fully loaded loop) Alarm:80 mA Alarm:70 mA <br /> Note:These ratings do not include the use of two-wire smoke modules. RZI16-2 Specifications <br /> Communication Line Max.20.6 V peak-to-peak Voltage <br /> Voltage 24V/Aux nominal: 24 VDC <br /> Terminal Rating 12 to 18 AWG(0.75 to 2.5 mm2) Supervisory current: 250 mA at 24 VDC nominal <br /> Circuit Current 0.5 A max. Alarm Current 1000 mA <br /> 24V/Aux minimum: 18.4 VDC <br /> Max total loop 66 0 24V/Aux maximum: 26.4 VDC <br /> resistance NAC1,NAC2 nominal: 24 VDC <br /> Max total loop 0.5 µF Current <br /> - capacitance Standby current <br /> Isolators 64 isolators maximum per loop(total both for 4.7 k EOL(U.S.) 4.8 mA/circuit <br /> isolator bases and modules) Standby current for <br /> Ground Fault 0 to 5 kfl 3.9 k EOL(Canada) 5.7 mA/circuit <br /> Impedance Alarm current <br /> Operating 32 to 120°F(0 to 49°C) at nominal voltage 31.1 mA/circuit <br /> Environment 0 to 93%noncondensinat 90°F(32° <br /> C Relay outputs <br /> Quantity 2 <br /> Type Rating(pilot duty) Programmable 24 VDC at 2.5 A <br /> Input circuit wiring 25 fl per wire <br /> SA-ETH Ethernet Interface Card resistance <br /> The SA-ETH card provides a Initiating device circuits <br /> . standard 10/100 Base Ethernet Quantity 16 <br /> network connection for connecting EOL resistor 4.7 kfl(U.S.);3.9 kO Canada <br /> to an intranet,a local network,or Zone voltage 22.78 V for 4.7 Id/(U.S.) <br /> the Internet.The card can be 22.08 V for 3.9 kO(Canada) <br /> -: used to download configuration Alarm current 31.1 mA/channel at nominal voltage <br /> programming from the i0-CU to Alarm impedance range <680 0r v - Trouble impedance range >5.55 kf) <br /> the panel. <br /> Supervised output circuits <br /> The Ethernet card is installed on EOL resistor 15 kfl <br /> the plastic assembly and connects Quantity 2 <br /> to the main circuit board via a Short circuit detection <2.6 kO <br /> MEI • Open circuit detection >61.9 kO <br /> ribbon cable. Contact ratings 24 VDC at 2.5 A(5 A for two NACs) <br /> SA-ETH specifications Compatible cabinets MFC(A),i01000,APS <br /> Ethernet 10/100 Base T <br /> Operating environment <br /> Temperature 32 to 120°F(0 to 49°C) <br /> Humidity 0 to 93%RH,noncondensing at 90°F <br /> (32°C) <br /> Page5of8 E85001-0135 <br /> Issue 1.5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.