My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Typical Wiring <br /> Modules will accept#18 AWG(0.75mm2),#16(1.0mm2), #14 AWG(1.50mm2)and#12 AWG(2.50mm2)wire sizes. <br /> Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog <br /> sheet for detailed wiring requirement specifications. <br /> AB4G AB4G AB4G <br /> Audible Base Audible Base Audible Base <br /> 0 0 fiN0 0 0 0 <br /> CI 6254A-003 <br /> EOL Relay <br /> Listed 24 VDC + <br /> Nominal Power o il _ _ _ _ 6 Mile A <br /> Supply _ , <br /> A <br /> ____ A..2 A p A <br /> u i <br /> A <br /> J I— — �1i— A A - <br /> • • • <br /> ®CR CRR A CT1 <br /> SIGH—CRR 0 0 <br /> 0 0 0 0 <br /> Signature A <br /> Controller = A Optional CR <br /> for disabling/disconnecting <br /> sounder base SIGA—MCRR <br /> SIGA-CRR Schematic SIGA-MCRR Schematic /® 0 0 ®\ <br /> Power h Power Out Pclarny Reverses Power In Power Out ~ <br /> _ cam When Activated Pdariry reverses F p 6254A-003 <br /> L.'.i + (+ T when activated. 0 Z `- ,t EOL Relay <br /> ,IC) t Audible 0 i required for <br /> mac= Bases i 2 ± a"' ^ supevision <br /> (i ■ yr H rn O O .- -1 <br /> 11 I I I I a <br /> Irr .I <br /> 4 3 2 1 t; x C�.IGa�ICl?LCt>,_.IP> —13 <br /> r r r <br /> i I o <br /> Signature A A 8 7 <br /> Notes Data Data Out + 4 11 • • • <br /> Circuit <br /> Al Refer to the Signature controller installation sheet for — For normal operation CT1 <br /> Q <br /> wiring. 9 *}_For General Fire <br /> Alarm Operation <br /> AOne Pair of Wires(24 Vdc power). uvULC Listed + 4 3 2 1 <br /> -- 24 Vdc power <br /> A One Pair of Wires(Signature Data). supply ar I r r I r t t t <br /> A\Single Wire(24 Vdc power). —� ' X <br /> 1 2 3 4 1 1 2 3 4 <br /> A The SIGA-U106R and the SIGA-U102R do not come t I lun•. MCRR <br /> with TB14. A A ' .il, .% 11 —UIOIRI series motherboard <br /> A The SIGA-U106 does not come with TB8 through Data Out+ <br /> �� .3 <br /> TB1 3. 4 P` • 2 No connections required for <br /> signature .ra� ( i - Q Q o 3 TB14 MCRR.Other modules may <br /> //\Supervised and power-limited. Dom •!Z require connections. <br /> circuit 1 ��� > q <br /> A\ If the source is nonpower-limited,maintain a space T81 % <br /> of 1/4 inch from power-limited wiring or use FPL, + <br /> FPLP,FPLR,or an equivalent in accordance with the Data In— 1 S ,11 i <br /> u u '' Green LED INormall <br /> National Dectrical Code. f `I f , `-13 Red LED(Active) <br /> �`,'az <br /> 9 Maximum#12 AWG(2.5 mm2 wire;Minimum #18 I f 1 <br /> ) No connections required for <br /> AWG 0.75 mm2 . 2•a ° Tais MCRR.Other modules may <br /> ) Green LED INorrnall � i o o EttaNlate,,...o o <br /> 10 End-of-Line Relay must monitor and report power Red LED(Active) • 1 2 4 require connections. <br /> supply trouble to control panel. A 0 <br /> 11 Class B Data wiring may be'7-tapped." Optional MCRR <br /> or MCR for No connections required for MCRR.Other <br /> disabling/disconnecting <br /> an audible base modules may require connections. <br /> Page 4 of 6 E85001-0239 <br /> Issue 1.1 <br />