My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Typical Wiring <br /> Modules will accept#18 AWG(0.75mm2),#16(1.0mm2),#14 AWG(1.50mm2)and#12 AWG(2.5mm2)wire sizes. <br /> Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog <br /> sheet for detailed wiring requirement specifications. <br /> Normally- Normally- <br /> Open Common Closed <br /> TB210(D®' <br /> 8 7 b <br /> • • at <br /> Red LED O 0 F Green LED <br /> (Alarm/Active) 4 3 2 1 (Normal) <br /> TB1 Ill®(D �`'111 Notes <br /> DATA IN(+) DATA OUT(+) <br /> I ARefer to Signature Loop Controller Installation <br /> Sheet for wiring specifications. <br /> 1 <br /> )} /2\NFPA 72 requires that the SIGA-CR/SIGA-MCR <br /> DATA IN(-) DATA OUT(-) be installed in the same room as the device it is <br /> From Signature Controller To Next Device controlling.This requirement may not apply in all <br /> or Previous Device <br /> A markets.Check with your local AHJ for details. <br /> ©The SIGA-U106R and the SIGA-U102R do not <br /> SIGA-CR Control Relay come with TB14. <br /> The SIGA-U106 does not come with TB8 through <br /> TB13. <br /> Normally Open Common Normally Closed ©Supervised and power-limited. <br /> /\If the source is nonpower-limited,maintain a <br /> space of 1/4 inch from power-limited wiring or use <br /> FPL,FPLP,FPLR,or an equivalent in accordance <br /> with the National Electrical Code. <br /> L-11 —j ® Maximum#12 AWG(2.5mm2)wire. <br /> A1 2 3 4 Min.#18(0.75mm2). <br /> Data In+ JJPfJi: A <br /> 4 :a�m� : Q 4 <br /> 32 <br /> 3 <br /> • 2 <br /> 1 �_ • 1 <br /> i TB14 <br /> No connections required for <br /> Data Out_+ f,g MCR.Other modules may <br /> require connections. <br /> d m <br /> Z K 1$ <br /> iQu s) 4I <br /> Q�3 <br /> Green LED(Normal) ?- , 1 <br /> Red LED(Active) 0WARR <br /> 000 a TB15 <br /> ittiWW <br /> A <br /> No connections required for <br /> MCR.Other modules may <br /> require connections. <br /> SIGA-MCR Control Relay <br /> Page 3 of 6 Fe,P': ,, ;3. ; E85001-0239 <br /> Not to be used for hest&if. >oses. Issue 1.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.