My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-01 Plans 2024-06-12
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-01
>
Plans
>
3003 W CASINO RD BLDG 45-01 Plans 2024-06-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2024 11:15:43 AM
Creation date
4/23/2024 9:41:11 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-01
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> REFER TO SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> L1:024 — UV45-2A TAMPER 2 TO ALLISON <br /> HEAT DETECTION GENERAL NOTES <br /> L1:026 — UV45-2A WF PRESSURE ZONE TEST 1. RISER DIAGRAM MAY NOT NOT SHOW ALL FIELD DEVICES, <br /> L1:025 — UV45-2A HI/LO AIR ATTIC POINTS SEE PLAN SHEETS FOR OF EQUIPMENT. <br /> 2. RACEWAY CONFIGURATION AND ROUTING SHOWN ARE <br /> I DIAGRAMMATIC AND DO NOT NECESSARILY REPRESENT <br /> PROCESS ACTUAL INSTALLATION. FINAL PATHS SHALL BE <br /> TO ALLISON AIR DETERMINED BY ELECTRICAL CONTRACTOR. <br /> PS WF VS HEAT DETECTION PLC <br /> ZONE TEST ENCLOSURE <br /> POINTS D <br /> SECOND FLOOR (LOW ATTIC) <br /> I I <br /> L1:011 — UV45-2B TAMPER 1-1:036 — SV45-10 WF PRESSURE PROCESS REFERENCE DRAWINGS <br /> L1:009 — UV45-2B WF PRESSURE L1:034 — SV45-8 WF PRESSURE%PD <br /> AIR <br /> L1:010 — UV45-2B HI/LO AIR L1:032 — SV45-6 WF PRESSURESYSTEM 1 E506-4 FIRE CANNON PANEL RISER <br /> I 1-1:030 — SV45-4 WF PRESSUREOVERRIDE 2 E6-2 FIRE ALARM SYSTEM PLAN — 2ND <br /> L1:028 — SV45-2 WF ISO TAMPER � FLOOR/ATTIC <br /> L1:027 — SV45-2 WF PRESSURE E703 SERIES PROCESS AIR PLC/FIRE ALARM <br /> 3 3 SYSTEM INTERLOCK <br /> %psP vs 2 2 <br /> WF WF WF <br /> L1:008 — MAN PULL COL L/6 P P P <br /> - SMK ® FACP — L1:001 SMK ® NAC PANELS 1:044 TO OTHER <br /> I STROBE LIGHTS-<A <br /> 1-1:007 — MAN PULL COL K/3 r FA — 1-1:002 � SV45-2 WF(M NITORED BY � 5 <br /> FA — 1-1:037 I s [ I HEAT DETECTION PANEL) FA — 1-1:038 s 6 E EX <br /> Ir TRBL — L1:003 <br /> SUPV — 1-1:004 WF F TRBL — L1:039 TRBL — 1-1:045 �TRBL — 1-1:046 <br /> L1:012 — SV45-1 WF PRESSURE TRBL — L1:006 I I r a CONSTRUCTION NOTES <br /> 45-01 FACP FIRE CANNON ALLISON HEAT NAC NEL 1 NAC PANEL 2 <br /> L1:013 — SV45-3 WF PRESSURE I <br /> ELEVATOR ®AD.5/12 FACP -1:042 — UV45-2C DETECTION PROVIDE (2) NAC PANELS, (1) FOR THE NEW <br /> L1:014 — SV45-5 WF PRESSUREI 15 �II/LO AIR PANEL (SYNCHRONIZED (SYNCHRONIZED SYNCHRONIZED HORN STROBE AND (1) FOR THE <br /> L1:015 — SV45-7 WF PRESSURE FACP F HORN/ TROBES) C1D1 CLASS 1, DIV 1 HORNS AND STROBES. <br /> -1:017 — SV45-9 WF ISO TAMPER I 1-1:043 — UV45-2C� HORN/STROBES) <br /> L1:016 — SV45-9 WF PRESSURE I FA PSEU O POINT WF 1 � PROVIDE NEW CIRCUIT FOR NOTIFICATION DEVICES. <br /> L1:022 — SV45-9 TAMPER EVT—FA-45-01 P P REPLACE EXISTING STROBE AND HORN WITH NEW <br /> L1:021 — SV45-7 TAMPER VS VS I P EL ® COL. C.5/9 COMBINATION HORN/STROBE TO COMPLY WITH <br /> L1:019 — SV45-5 TAMPER vs WF PD WF P WF P WF P WF P I X2V01—iM4/17 NFPA STROBE SYNCHRONIZATION REQUIREMENTS. <br /> L1:018 — SV45-3 TAMPER VS I LX2V01-1M4/4 I X2V01-107 9 X2V01-1D7 3 4 MAN PULL COL F 3 — 1-1:041 <br /> 1-1:018 — SV45-1 TAMPER VS / / / <br /> I SV45-10 TAMPER — 1-1:037 ® PROVIDE NEW CONDUCTORS AND WIRING. <br /> (PLV—OUTSIDE) _ _ _ MECHANICAL ROOM WEST 109U 1-1:040 — MAN PULL COL G/5�` F F SV45-8 TAMPER — 1-1:035 <br /> P VS VS SV45-6 TAMPER — 1-1033 REPLACE EXISTING STROBE WITH NEW STROBE TO <br /> VS SV45-4 TAMPER — L1:031 COMPLY WITH NFPA STROBE SYNCHRONIZATION <br /> SV45-2 TAMPER — L1:029 REQUIREMENTS. <br /> FIRST FLOOR (PIV—OUTSIDE) <br /> -----— ------— — — — — — — © REPLACE EXISTING HORN WITH NEW HORN TO <br /> COMPLY WITH NFPA HORN SYNCHRONIZATION <br /> REQUIREMENTS. <br /> PROVIDE NEW SMOKE DETECTOR AND ASSOCIATED <br /> OUTSIDE — EAST OF 45-01 45-01 EAST 45-01 WEST OUTSIDE — WEST OF 45-01 RACEWAY AND WIRING. <br /> ® PROVIDE 1/2"C TO NAC PANEL 1 AND NAC <br /> PANEL 2 TO MONITOR TROUBLE SIGNALS. <br /> BUILDING FIRE ALARM SYSTEM RISER <br /> SCALE: NONE E506-3 <br /> WNW— DATE <br /> GOW <br /> SYM REVISION BY APPROVED DATE SYM REASON BY APPROVED DATE <br /> ACCEPTABILITY ZO 12.04.19 SUBTRLE CURRENT REVISION SYMBOL DATE <br /> EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 12.04.19 THIS DESIGN AND/OR ZHECKED O 12.04.19 FIRE ALARM SYSTEM RISER DIAGRAM C 04.14.21 <br /> SPECIFICATION IS APPROVED SHEET <br /> -JIN— TLE <br /> A SHOP DRAWINGS AGOW/HG 04.10.20 BOE/A/G® APPROVED BY DEPT. DATE CK 12.04.19 n NAC MODIFICATION E506 3 <br /> B AS BUILTS AGOW/HG 08.21.20 N <br /> C NAC MODIFICATION AGOW/HG 04.14.21 Pete Linamen APPROVED <br /> CK 12.04.19 BUILDING 45-001 <br /> JOB NO. COMP NO. <br /> A ELECTRICAL MASTER EVERETT, WA. X40 NO. 45-001—E506-3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.