My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-01 Plans 2024-06-12
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-01
>
Plans
>
3003 W CASINO RD BLDG 45-01 Plans 2024-06-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2024 11:15:43 AM
Creation date
4/23/2024 9:41:11 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-01
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1-1012 12D SV45-1 WF PRESSURE WATERFLOW PRESSURE SWITCH 1E264 FIRE ALARM ABBREVIATIONS LEGEND <br /> L1:018 134 SV45-1 TAMPER PIV SPRINKLER VALVE 1E264 <br /> L1:027 130 SV45-2 VVF PRESSURE WATERFLOW PRESSURE SWITCH WITH DELAY E506-2 ALT SECONDARY OR ALTERNATE ELEVATOR RECALL <br /> L1:028 13E SV45-2 WF ISO TAMPER WATERFLOW ISO TAMPER SWITCH E506-2 BEAM DET BEAM DETECTOR <br /> L1:029 140 SV45-2 TAMPER PIV SPRINKLER VALVE 1 E260 CDR COMPUTER/NEfWORK/DATA/IDF ROOM <br /> 1-1:013 12E SV45-3 WF PRESSURE WATERFLOW PRESSURE SWITCH 1E264 COL COLUMN <br /> 1-1:019 135 SV45-3 TAMPER PIV SPRINKLER VALVE 1 E264 COMM FAIL COMMUNICATION FAILURE <br /> 1-1:030 141 SV45-4 WF PRESSURE WATERFLOW PRESSURE E506-2 CTRL CONTROL <br /> 1-1:031 142 SV454 TAMPER PIV SPRINKLER VALVE 1 E260 CW CATWALK <br /> DMPR DAMPER <br /> 1-1:014 130 SV45-5 WF PRESSURE WATERFLOW PRESSURE SWITCH 1E264 DO DUCT SMOKE DETECTOR <br /> L1:020 136 SV45-5 TAMPER PIV SPRINKLER VALVE 1 E264 DIESEL DIESEL <br /> L1:032 143 SV45-6 WF PRESSURE WATERFLOW PRESSURE SWITCH E506-2 FP FIRE PUMP <br /> L1:033 144 SV45-6 TAMPER PIV SPRINKLER VALVE 1 E260 ELEC ELECTRICAL; ELECTRICAL ROOM <br /> 1-1:015 131 SV45-7 WF PRESSURE WATERFLOW PRESSURE SWITCH 1E264 ELEV ELEVATOR <br /> EPP EXCESS PRESSURE PUMP <br /> 1-1:021 137 SV45-7 TAMPER PIV SPRINKLER VALVE 1E264 FACP FIRE ALARM CONTROL PANEL <br /> L1:034 145 SV45-8 WF PRESSURE WATERFLOW PRESSURE SWITCH E506-2 ELEV FF HAT LIGHT FIRE FIGHTER HAT LIGHT IN A ELEVATOR <br /> L1:035 146 SV45-8 TAMPER PIV SPRINKLER VALVE 1E260 FLR FLOOR <br /> L1:016 132 SV45-9 WF PRESSURE WATERFLOW PRESSURE SWITCH WITH DELAY 1E264 FM FIRE MAIN VALVE <br /> L1:017 133 SV45-9 WF ISO TAMPER WATERFLOW ISO TAMPER SWITCH 1E264 HEAT HEAT DETECTOR <br /> L1:022 138 SV45-9 TAMPER PIV SPRINKLER VALVE 1 E264 INTDEV INTERFACE DEVICE, MONITORING OR CONTROL <br /> ISO ISOLATION VALVE <br /> L1:036 147 SV45-10 WF PRESSURE WATERFLOW PRESSURE SWITCH E506-2 KITCHEN KITCHEN <br /> L1:037 148 SV45-10 TAMPER PIV SPRINKLER VALVE 1E260 L BATT LOW BATTERY REFERENCE DRAWINGS <br /> L1:023 139 SV45-11 TAMPER PIV SPRINKLER VALVE 1E264 L FUEL LOW FUEL (FIRE PUMP DIESEL TANK IS BELOW 50% FILLED) <br /> 1-1:024 13F UV45-2A TAMPER OS&Y VALVE-G/2-E7 E6-2 LBY LOBBY <br /> 1-1:025 136 LIIHI/LO AIR G/2-E7 E6-2 LRD LOW RATE DISCHARGEMAN PULL MANUAL PULL STATION <br /> L1:026 13C UV45-2A WF PRESSURE G/2-E7 E6-2 MECH MECHANICAL ROOM <br /> L1:011 12C UV45-26 TAMPER OS&Y VALVE-MA-1 E264 1 E264 NAC NOTIFICATION APPLIANCE CIRCUIT OR POWER SUPPLY <br /> L1:010 12B UV45-26 HULO AIR MA-1E264 1E264 OS&Y OUTSIDE SCREW AND YOKE VAVLE <br /> 1-1:009 12F UV45-2BWFPRESSURE Ml4-1E264 1E264 PD PUMP DISCHARGE VALVE <br /> 1-1:042 14D UV45-2C HI/LO AIR Dl8-E506-2 E506-2 PH PENTHOUSE <br /> L1:043 14E UV45-2C FA PSUEDO POINT-SV45-2 WF&UV45-2C HI/LO AIR-D8/E506-2 E506-2 PIV POST INDICATOR VALVE <br /> POWER FAIL FACP POWER FAILURE <br /> L1:008 129 MAN PULL COL.U6 PAINT HANGER U6 1E264 PREACT PREACTION SYSTEM GENERAL NOTES <br /> L1:007 128 MAN PULL COL.W3 OUTSIDE EAST STAIRWELL 1E254 PRI PRIMARY <br /> L1:040 14B MAN PULL COL.G/5 PAINT HANGER G/5 1E260 PS PUMP SUPPLY VALVE <br /> 1-1:041 14C MAN PULL COL.F/3 OUTSIDE WEST STAIRWELL 1E260 PWR POWER <br /> 1-1:001 122 SMK @ FACP 1 E264 RF ROOF <br /> 1-1:005 126 ELEV 15 FA 1E264 RLY RELAYSEC SECTION VALVE <br /> L1:006 127 ELEV 15 TRBL 1E264 SHUNT SHUNT TRIP <br /> L1:002 123 FIRE CANNON PNL FA 1E264 SMK SMOKE DETECTOR <br /> L1:003 124 FIRE CANNON PNL TRBL 1E264 STL STALL <br /> L1:004 125 FIRE CANNON PNL SUPV 1 E264 STROBE STROBE, HORN OR ANY NOTIFICATION DEVICE <br /> 1-1:038 149 HEAT DET.PANEL FA E506-2 <br /> SUPPR SUPPRESSION <br /> SUPV SUPERVISORY <br /> L1.039 14F HEAT DET.PANEL TRBL E506-2 SV <br /> ''7344 150ri *`,'SMK@NAC"PANELS E506-2 SPRINKLER VALVE <br /> TAMPER TAMPER SWITCH <br /> 1-1:045 151- . NAG PANEL 1`TRBL E50'6 2- TL300 TL300 TYCO COMMUNICATION DEVICE <br /> L1�046 'j52_',' NACPANEL2TRBL E506-2 TRBL TROUBLE <br /> UV UNIT VALVE <br /> VLV VALVE <br /> BUILDING FACP POINTS LIST zN ZONE -CONSTRUCTION <br /> SWITCH CONSTRUCTION NOTES <br /> SCALE: NONE E5`06 <br /> SEQUENCE OF OPERATIONS <br /> 1. ALARM CONDITION: <br /> 1.1 ACTIVATION OF ANY ALARM SHALL CAUSE THE FOLLOWING: <br /> a. Alarm indicator LED on FACP to illuminate. <br /> b. FACP Internal Sounder to activate. <br /> c. Display proper message on FACP to display ALARM POINT LOCATION INFORMATION. <br /> d. Activate FACP DACT, transmit ALARM signal to Central Station monitoring company. <br /> 2. SUPERVISORY CONDITION: <br /> 2.1 ACTIVATION OF ANY SUPERVISORY CONDITION SHALL CAUSE THE FOLLOWING: <br /> a. Supervisory indicator LED on FACP to illuminate. <br /> b. FACP Internal Sounder to activate. <br /> c. Display proper message on FACP to display SUPERVISORY POINT LOCATION INFORMATION. <br /> d. Activate FACP DACT, transmit SUPERVISORY signal to Central Station monitoring company. <br /> 3. TROUBLE CONDITION: <br /> 3.1 ACTIVATION OF ANY TROUBLE CONDITION SHALL CAUSE THE FOLLOWING: <br /> a. Trouble indicator LED on FACP to illuminate. <br /> b. FACP Internal Sounder to activate. <br /> c. Display proper message on FACP to display TROUBLE CONDITION. , <br /> d. Activate FACP DACT, transmit TROUBLE signal to Central Station monitoring company. <br /> SEQUENCE OF OPERATIONS GOW <br /> SCALE: NONE ESDRAWN DATE C <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br /> ACCEFTA611-ITY SUBTITLE CURRENT REVISION InIVPCL DALE <br /> - EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 12.04.19 THIS DESIGN AND/OR CH KED 12.04.19 04.14.21 <br /> FIRE ALARM SYSTEM DETAILS <br /> SPECIFICATION IS APPROVED ZO 12.04.19 sNEet <br /> A SHOP DRAWINGS AGOW/HG 04.10.20 BOE//V6® m APPROVED BY DEPT. DATE CK 12.04.19 TTE` NAC MODIFICATIONCHECKED E506 <br /> B AS BUILTS AGOW/HG 08.21.20 CK12.04.19 <br /> C NAC MODIFICATION AGOW/HG 04.1421 Pete Linamen R BUILDING 45-001 JOB NO. COMP NO. <br /> °P^'p aria APPROVED ELECTRICAL MASTER EVERETT, WA. DWG No. 45-001—E506 <br />
The URL can be used to link to this page
Your browser does not support the video tag.