- LEGEND <br /> *SPRINKLER VALVE WATERFLOW ALARM - REFER TO SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> MONITORING AND WATERFLOW ISOLATION <br /> SUPERVISION EQUIPMENT INSTALLATION <br /> F WATERFLOW <br /> TO SPRINKLERS I PRESSURE SWITCH <br /> WITH BUILT-IN I GENERAL NOTES <br /> RETARD/DELAY, <br /> POTTER #WFSR-F 1. ELECTRICAL CONTRACTOR SHALL INSTALL ENCLOSURE(S) <br /> (ALARM) <br /> AND POWER. <br /> 1 I 2. WET RISER/PIPING CONFIGURATION SHOWN IS <br /> DIAGRAMMATIC AND DOES NOT NECESSARILY REPRESENT <br /> ANY SPECIFIC INSTALLATION. <br /> L_ TO WATER <br /> MOTOR GONG <br /> WATER PRESSURE GAUGE J <br /> f — _ — <br /> (SYSTEM PRESSURE) I ALARM LINE 9 WATERFLOW <br /> (ISOLATION ISOLATION <br /> (OPEN) VALVE, TAMPER SWITCH, ANALOG PHONE LINE (PRIMARY) <br /> APOLLO POTTER #RBVS FIRE ALARM <br /> BY-PASS LINE L#94A-103-27 (SUPERVISORY) CONTROL *TELCO I <br /> I— — — — PANEL DEMARC MONITORED BY TYCO AND <br /> (FACP) SIGNAL SENT TO CENTRAL REFERENCE DRAWINGS <br /> BOEING FIRE DEPARTMENT <br /> CHECK VALVE } o RETARD ANALOG PHONE LINE (SECONDARY) <br /> IN CHAMBER FIRE ALARM CABLING _ <br /> WATER PRESSURE GAUGE CHECK I VALVE S SMOKE DETECTOR, *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY <br /> (SUPPLY PRESSURE) OPEN (CLOSED) PULL STATION, WATER CODE, AS SHOWN. <br /> L _ y— — J FLOW & TAMPER <br /> SWITCHES *BOEING SERVICES REQUEST MUST BE MADE CONSTRUCTION NOTES <br /> OS&Y TAMPER ry REQUESTING: TWO ANALOG VOICE (BUSINESS FLAT LINE) <br /> SWITCH WATER BY-PASS TEST oai HORNS BELLS JACK/CONNECTIONS. AFTER JACKS ARE INSTALLED, <br /> (SUPERVISORY) VALVE (CLOSED) STRAINER & STROBES ANALOG LINES MUST BE REQUESTED TO CONNECT 1. ALL WIRING SHALL BE DRESSED AND TRAINED IN A <br /> DRIP <br /> CUP ANALOG VOICE JACKS. WORKMANLIKE MANNER. <br /> (III 2. ALL WIRES SHALL BE LABELED WITH WIRE ID. <br /> 3. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> FIRE ALARM SYSTEM SIGNAL AND COMMUNICATIONS OVERVIEW 4. ALL PENETRATIONS TO FIRE ALARM CONTROL PANEL AND <br /> OS&Y VALVE SCALE: NONE E5064 TELECOMMUNICATIONS ENCLOSURES SHALL BE IN <br /> CONTROL (OPEN) ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br /> CHECK <br /> VALVE PROVIDE PHENOLIC LABELS, INSTALL AND CENTER ON <br /> UPPER ENCLOSURE DOOR WITH FACP AND POWER <br /> CIRCUIT IDENTIFICATIONS. LABELS SHALL HAVE WHITE <br /> DRAIN LETTERING AND RED BACKGROUND. <br /> WATER SUPPLY PIPE © CONFIGURE FIRE ALARM CONTROL PANEL TO TRANSMIT <br /> PRIMARY AND SECONDARY COMMUNICATIONS IN A <br /> *NOTE: SIMULTANEOUS MANNER IN ACCORDANCE WITH <br /> LIMIT OF ONE (1) ISOLATION NFPA72-2016 26.6.4.1.4(B)(7). <br /> VALVE ON ALARM SENSING LINE. <br /> SPRINKLER RISER WATERFLOW PRESSURE SWITCH W/DELAY DETAIL � PROVIDE CONDUIT WITH LWTIT <br /> SCALE: NONE E506-1 ® PROVIDE LINE SIZE BALL VVAALVVEE WITH LOCKABLE HANDLE, <br /> TYPE AS NOTED, ON ALARM LINE UPSTREAM OF ALARM <br /> SWITCH. FIELD VERIFY CORRECT SIZE. <br /> TAMPER SWITCH, TYPE AS NOTED, ON ISOLATION VALVE AS <br /> SHOWN. <br /> WATERFLOW PRESSURE SWITCH WITH ADJUSTABLE DELAY. <br /> 11. CONFIRM ONLY ONE (1) ISOLATION VALVE IS INSTALLED <br /> ON WATERFLOW SENSING LINE. WHERE EXISTING <br /> 6 INSTALLATIONS HAVE MORE THAN ONE (1) VALVE, <br /> 5 COORDINATE REMOVAL OF ADDITIONAL VALVE(S) WITH <br /> BOEING CONSTRUCTION MANAGER. <br /> 12"X12" PHONE J-BOX 12. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> FACP EVT-FA-45-01 FOR PRIMARY AND <br /> (BY FIRE ALARM VENDOR) SECONDARY PHONE PRIMARY CONNECTION:Q INSTALLATION OF DEVICES AND PIPING MODIFICATIONS. <br /> LINE JACKS PHONE LINE TO <br /> (BY ELECTRICAL TELEPHONE <br /> CONTRACTOR) BACKBOARD/ DEMARC. <br /> (CABLING BY BOEING <br /> IT) <br /> SECONDARY CONNECTION:�7 <br /> PHONE LINE TO TELEPHONE <br /> BACKBOARD/DEMARC. (CABLING <br /> BY BOEING IT) <br /> FIRE ALARM SYSTEM COMMUNICATIONS DETAIL (M iA%I <br /> SCALE: NONE E506-1 <br /> G 0W <br /> 5YM DRAWN DATE � <br /> REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br /> ACCEPTABILITY 20 120419 SUBTITLE CURRENT REVISION SYMBOL DATE 04.14.21 <br /> EVEREff FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 12.04.19 THIS DESIGN AND/OR FIRE ALARM SYSTEM DETAILS <br /> SPECIFICATION IS APPROVED ZO 12.04.19 SHEET <br /> A SHOP DRAWINGS AGOW/HG 04.10.20ENGINEER T� <br /> BOE//VG® APPROVED BY DEPT. DATE CK 12.04.19 NAC MODIFICATION E506-1 <br /> B AS GUILTS AGOW/HG 08.21.20 <br /> C NAC MODIFICATION AGOW/HG Pete APPROVED JOB N0. COMP No. <br /> � CK 12.04.19 BUILDING 45-001 <br /> APPROVED ELECTRICAL MASTER EVERETT, WA. Dwc NO. 45-001-E506-1 <br />