Laserfiche WebLink
TAMPER-RESIST FEATURE FIGURE 5A.ACTIVATE TAMPER-RESIST FEATURE <br /> NOTE:Do not use the tamper-resist feature if a removal tool will be used. PLASTIC LEVER <br /> The detector base includes a tamper-resist feature that prevents removal of the <br /> detector without using a small screwdriver or similar tool. <br /> To activate this feature,use needle-nose pliers to break the tab on the detector <br /> base as shown in Figure 5A.Then,install the detector. <br /> To remove the detector from the base once the tamper-resist feature has been BREAK TAB AT DOTTED LINE BY <br /> activated, remove the decorative ring by rotating it in either direction and TWISTING TOWARD CENTER OF BASE <br /> pulling it away front the base.Then,insert a small screwdriver into the notch, <br /> as indicated in Figure 5B, and press the plastic lever toward the mounting C0130-00 <br /> surface before rotating the detector counterclockwise for removal. FIGURE 5B.DETECTOR REMOVAL <br /> The tamper-resist feature can be defeated by breaking and removing the plas- USE SMALL-BLADED SCREWDRIVER TO PUSH <br /> PLASTIC LEVER IN DIRECTION OF ARROW <br /> tic lever from the base. However, this prevents the feature from being used u <br /> again. <br /> REMOTE ANNUNCIATOR(RA300Z) / \ <br /> Connect the remote annunciator between terminals 1 and 3 using the spade <br /> lug terminal included.The spade lug terminal is connected to the base term(- C0130-00 <br /> ttal as shown in Figure 6. FIGURE S.CONNECTION TO REMOTE ANNUNCIATOR TERMINAL <br /> It is not acceptable to have three stripped wires under the same wiring ter- STRIPPED WIRE <br /> minal unless they are separated by a washer or equivalent means.The spade / ^ , <br /> lug supplied with the model RA100Z is considered an equivalent means.See frl <br /> Figure 3 for proper installation. <br /> FIGURE 3.TYPICAL WIRING DIAGRAM FOR 2-WIRE LOOP <br /> REMOTE CAUTION:DO NOT LOOP WIRE t=t � <br /> ANNUNCIATOR UNDER TERMINAL 1 OR 2.BREAK WIRE RUN TO PR <br /> �\ \\ <br /> MirSUPERVISION OF CONNEOCTIONS. ^,\]���`\�\`{ I\`\\\�\\�l� <br /> w / ^—-- WIRE WITH SPADE LUG <br /> 05 <br /> coil6-00 <br /> p..4 <br /> („.. <br /> -J r$10. <br /> W~ <br /> Z <br /> io <br /> :71U / I <br /> -- (-) CLASS A OPTIONAL WIRING <br /> t+1 <br /> CO129-02 <br /> FIGURE 4.TERMINAL WIRE INSTALLATION <br /> THIS NOT THIS <br /> 0 0 <br /> C'4973-00 <br /> Please refer to insert for the Limitations of Fire Alarm Systems <br /> THREE-YEAR LIMITED WARRANTY <br /> System Sensor warrants its enclosed smoke detector base to be free front defects in ma- 12220 Rojas Drive,Suite 700,El Paso TX 79936 USA.Please include a note describing the <br /> terials and workmanship under normal use and service for a period of three years from malfunction and suspected cause of failure.The Company shall not be obligated to repair <br /> date of manufacture. System Sensor makes no other express warranty for this smoke or replace units which are found to be defective because of damage,unreasonable use, <br /> detector base.No agent,representative,dealer,or employee of the Company has the au- modifications,or alterations occurring after the date of manufacture.In no case shall the <br /> thority to increase or alter the obligations or limitations of this Warranty.The Company's Company be liable for any consequential or incidental damages for breach of this or any <br /> obligation of this Warranty shall he limited to the repair or replacement of any part of other Warranty,expressed or implied whatsoever.even if the loss or damage is caused by <br /> the smoke detector base which is found to he defective in materials or workmanship the Company's negligence or fault.Some states do not allow the exclusion or limitation of <br /> under normal use and service during the three year period commencing with the date of incidental or consequential damages,so the above limitation or exclusion may not apply <br /> manufacture.After phoning System Sensor's toll free number 800-SENSOR2(736-7672) to you.This Warranty gives you specific legal rights,and you may also have other rights <br /> for a Return Authorization number,send defective units postage prepaid to:Honeywell, which vary from state to state. <br /> System Sensor is a registered trademark of Honeywell International.Inc. <br /> 2 156-6566-001 <br /> ©2017 System Sensor. 11/17/2017 <br />