2611 ROCKEFELLER AVE 2022 ROCKEFELLER SQUARE 2 Plans 2024-04-26
>
Address Records
>
ROCKEFELLER AVE
>
2611
>
ROCKEFELLER SQUARE 2
>
Plans
>
2611 ROCKEFELLER AVE 2022 ROCKEFELLER SQUARE 2 Plans 2024-04-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2024 9:18:43 AM
Creation date
4/24/2024 7:48:45 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2611
Tenant Name
ROCKEFELLER SQUARE 2
Permit
FA2205-007
Year
2022
Notes
INSTALL LOW VOLTAGE FIRE ALARM SYSTEM IN NEW (4) STORY BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE PROTECTION, INC. 8 11410 Ash Way,Ste 8 a <br /> Lynnwood,WA 98037 <br /> 14251 290-9600 Mqr 2 e, May 5,2022 <br /> CITY2022 <br /> CITY OF EVERETT - PLAN REVIEW perOF e v�R <br /> RE; Rockefeller Square Apartments <br /> rvi�e E ? <br /> 2611 Rockefeller Ave <br /> Everett, WA 98201 <br /> SCOPE OF WORK: Installation of a Fire Alarm System in a new construction of (4) <br /> story, fully sprinkled residential building w/ (1) level of parking. The Fire Alarm <br /> System will monitor the Automatic Fire Sprinkler System, and will provide Occupant <br /> Notification throughout. The Occupant Notification in the residential units shall produce <br /> the required 520hz Low Frequency signal. Occupant Notification in the common areas will <br /> be Ansi-Temporal. Automatic smoke detection will be provided above the FACP, AES Radio, <br /> and the Remote Power Supply. A Remote Annunciator will be installed in the entry lobby as <br /> shown. All fire sprinkler water-flow switches, dry-flow switches, and supervisory <br /> switches shall be monitored by the Fire Alarm System. The Fire Alarm Control Panel and <br /> Remote Annunciator will provide status of the Fire Alarm. The Fire Alarm System will <br /> activate all Occupant Notification, close FSD's in rated walls, and unlock all <br /> electronically locked egress doors on any general fire alarm Signal. The means of signal <br /> transmission to the central supervising station will be via the FACP's onboard DACT and <br /> AES Radio. <br /> A full pre-test shall be conducted and completed prior to calling the AHJ for <br /> acceptance testing. A completed NFPA-72 completion form and AES radio table report will <br /> be provided to the AHJ at the time of the fire final acceptance test. Copies of all <br /> record documents will be place in the FA Document Cabinet at the FACP. System has been <br /> designed per IBC, IFC, NFPA 70 & 72 and your additional requirements. <br /> INSTALLATION COMPANY <br /> Fire Protection, Inc. <br /> 17410 Ash Way Ste 8, Lynnwood, WA 98037 <br /> WSCL# FIREPI*021ML UL CERT #608242-002 <br /> APPROVED UL MONITORING COMPANY <br /> Alarm Center, Inc. /FPI <br /> 4300 3rd Ave. SE Lacey, WA 800-429-0991 <br /> UL CERT #902799-02 <br /> AMBIENT TEMPERATURES <br /> No area with alarm service equipment shall <br /> fall below 40 degrees, common areas shall <br /> be at 68 degrees per builder <br /> AMBIENT NOISE RANGE <br /> All areas serviced by the Fire Alarm Control and <br /> notification system will be as listed for <br /> per UBC listings, per builder. <br />
The URL can be used to link to this page
Your browser does not support the video tag.