My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4407 HOYT AVE 2024-05-22
>
Address Records
>
HOYT AVE
>
4407
>
4407 HOYT AVE 2024-05-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2024 7:40:48 AM
Creation date
5/7/2024 10:09:07 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
4407
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ter: <br /> APARTMENTS ON INC. <br /> 17410 Ash Way,Ste 84407 HOYT Lynnwood,WA <br /> 98037 <br /> 425-290-9600 <br /> FPISEATTLE.COM <br /> AES RADO D <br /> TYPICAL INSTALLATION DETAIL SHEET INDEX <br /> NFPA <br /> SHEET # SHEET DESCRIPTION 000805173 <br /> FA 0.0 FIRE ALARM : AES INSTALLATION ROY L CATS <br /> QYpOTECl/O <br /> �Q 2 <br /> PROJECT DETAILS <br /> O O ry NFPA S <br /> 1. THE EXISTING RESIDENTIAL BUILDING IS FULLY-SPRINKLED AND HAS AN EXISTING FIRE ALARM CONTROL �i2CFPS <br /> 1 <br /> PANEL(DMP XR5FC) LOCATED IN THE BUILDING'S SPRINKLER RISER ROOM. <br /> O O O O O #1473 <br /> 2. A NEW UL LISTED WIRELESS RADIO COMMUNICATOR (7707-88-ULP) IS BEING INSTALLED AT THE FACE. ALL <br /> ® cw SIGNALS WILL BE TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. A 12VDC 12Ah <br /> mDvire� <br /> WIRE O BATTERY WILL BE INSTALLED IN THE NEW AES RADIO. - <br /> CONDUIT <br /> Cl UI BE IN O 3. THE NEW AES RADIO SHALL TRANSMIT THE EXISTING SYSTEM'S CURRENT REPORTING ZONES. i <br /> � LL <br /> aEu - O OOO O 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. <br /> � rc <br /> wo w <br /> O 000000 O H V U m K <br /> a1 <br /> siid PROJECT CONTACT INFO o <br /> R 0 f JFt9� <br /> �g >oOwn< <br /> OWNER FIRE ALARM CONTRACTOR <br /> MAPLE LEAF PROPERTY MANAGEMENT FIRE PROTECTION INC ° m o <br /> ° ° PO BOX 75086 17410 ASH WAY, Ste 8 m#w w~ <br /> BATTERY SEATTLE, WA 98175 LYNNWOOD, WA 98037 z?; w o <br /> 12VDC 12ANP CONTACT : TINA BECK CONTACT : DAVID MOW ;w j a-p > <br /> - - PHONE :425.343.7373 PHONE : 425.290.9600 °z rc H a o <br /> ting@mapleleafmgt.com david@fpiseattle.com <br /> AES-7707 RADIO CONMJN[CATOR REVISION RECORD <br /> DATE/DESCRIPTION <br /> CODE INFO <br /> AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> FIRE CODE : INTERNATIONAL FIRE CODE, 2018 EDITION <br /> BUILDING USE AND OCCUPANCY : (R-2) FULLY-SPRINKLED <br /> STANDARDS: 2018 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT's STANDARDS <br /> CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> REMOTE SUPERVISING STATION : SECURITAS INC. <br /> PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION INC <br /> PARCEL NUMBERS : 00407800400200 <br /> INSTALLATION NOTES <br /> EXISTING FIRE ALARMCONMOLPANNEL, <br /> 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS-BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> VICINITYMAP SEQUENCE OF OPERATIONS PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 10.30.23 <br /> SYSTEM OUTPUTS 5. THE SYSTEM WILL BE 100% PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> Required Fire Safety Control PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> Central Supervising Station INSPECTION. <br /> ee <br /> Control Unit Annunciation ,� 6. THE AES RADIO REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL <br /> y �® DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> c o TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT U) <br /> om y.,g ®-m � (NFPA72, SECTION 10.5.5.2). Z M <br /> O4iF W LU N <br /> DELTA { Lake evens ym=�yo�m�Jr DEVICE INSTALLATION REQUIREMENTS Q <br /> yew y$ e C <br /> ° 2 o " o zr 'r <br /> y•r oc c'm�.F ,Qm ° Q 0 <br /> mz a y h FIRE ALARM DEVICE INSTALLATION REQUIREMENTS _ <br /> NOT PERMITTED Q ILLI <br /> ,0 l'.C� O Uj <br /> BRACKET HERE 4" LL <br /> DIFFUSER <br /> .- F- -F. F- .°a m r m d-eox calx = <br /> ;zs 4407 HOYT AVE Q c c y '� 3 m� ///�\\\ O W <br /> EVERETT,WA 98203 B nk c"� �c"�c"� FA DEVICE DETECTOR SMOKE <br /> Q Q Q�P�.°�P�P Q ® AWAL MINIM <br /> FROM NOT PERMITTED <br /> .� II HIII No' SYSTEM INPUTS B D F H � HVAC DIFFUSERS HERE <br /> Mu heo _ Sno 1 Manual Fire Alarm Pull-Station SMOKE <br /> ♦ ♦♦ 1 H S <br /> 2 Smoke Detectors ♦ ♦♦ 2 <br /> 3 Wet l Dry Flow ♦ ♦♦♦ 3 - SHEET TITLE <br /> ,R ¢ MAX HEIGHT 92 A.F.F <br /> 4 Unused 4 MIN HEIGHT s2•aE.F ® RG 3 FIRE ALARM <br /> a 5 Sprinkler Tamper PIV 5 <br /> W <br /> -- � P P ♦ ♦ AAES RADIO <br /> o) 6 Unused 6 � COMMUNICATOR <br /> JCASCADE vie nshorr 7 Fire Alarm AC Power Failure ♦ ♦ 7 ® O - INSTALLATION <br /> V,Ook Not to Scale- 66"1A*LF 60"AF.F pULL� <br /> oo M 8 Fire Alarm System Low Battery ♦ ♦ 8 <br /> 8 Open Circuit ♦ ♦ 9 4e•Arr SHEET NUMBER <br /> 10 Ground Fault ♦ ♦ 10 <br /> A B C D E F G H I -I <br /> FA 0.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.