EXISTING FRCP <br /> PRODUCT SPECIFICATION <br /> Five-Zone Fire Panels with Built-in <br /> Communicator <br /> MODELS XR5FC and XR5SL <br /> Description <br /> The XR5FC Commercial Fire and XR5SL Slave <br /> Communicator panels from DMP are the latest in a series 01 <br /> of innovative newfire products set to define the standard for <br /> fire alarm system performance. The XR5 panels feature i <br /> built-in 2-line dialers, 500mA of auxiliary power,one Class <br /> A (Style D) zone for sprinkler supervision, four Class B <br /> (Style A) smoke detector zones, 12 or 24 VDC input, two <br /> Form C outputs,four annunciator outputs,and a 4-wire bus <br /> for remote LED or LCD annunciators. <br /> Both panelsalso providesuch outstanding software features System Features <br /> as one-man walk test,passcode protected operation,cross • One Class A(Style D)waterflow zone <br /> zoning,fire verify, and fire retard zone programming, built- . Four Class B (Style A)2-wire smoke detector zones <br /> in programmer and diagnostics, and remote upload/ <br /> download capability. There's also a Fire Drill feature that 100mA 12 VDC switched 4-wire smoke power(XR5FC) <br /> allows an authorized user to sound just the system's bells • Two Form C relay outputs <br /> for evacuation exercises. The following sections highlight • Four open collector outputs for annunciation <br /> the unique features of the XR5FC and XR5SL fire panels. . Built-in dual phone line module with line monitoring <br /> Communication • 1.5 Amp alarm bell output (XR5FC) <br /> The XR5 panels each contain a built-in dual phone line • 500mA auxiliary output <br /> module with line supervision and can communicate to one • Operates on 16 VAC or 24 VDC primary power and <br /> or two remote receivers using Synchronous Data Link 12 VDC secondary power <br /> Control (SDLC) digital dialer or 4-2 formats. You can also . Compatible with a variety of LED and LCD keypads <br /> selectively enable alarm,supervisory/trouble,backup,and . One man Walk Test <br /> Recall Test reporting to either of the two receivers. <br /> • Fire Drill feature for practice evacuations <br /> Variety of Keypad Styles • DMP SDLC dialer or 4-2 communication <br /> For system annunciation, you can select from several . Programmable reporting to one or two receivers <br /> keypad styles to meet a variety of fire system requirements. <br /> The Model 692F LED keypad provides individual alarm and ' Remote upload/download with Remote Accessi"" <br /> trouble LEDs as well as power,system trouble,and silenced • Individual zone programming for fire, fire verification, <br /> LEDs along with a full function, backlit keyboard. You can retard delay, cross zoning, and fire supervisory <br /> also choose from 670 or690 series alphanumeric keypads. • Inherent power limited circuits <br /> Both LED and alphanumeric keypads meet all requirements <br /> for local system operation. Panel Specifications <br /> For slave communicator applications, an enclosure door Primary Power 16.5 VAC 40VA transformer <br /> mounted Model 377 Trouble Annunciator Module provides <br /> Trouble and System OK LEDs with audible alert and a Secondary Power 12 VDC 6.5 Ah battery <br /> Silence button for acknowledging trouble conditions. This Auxiliary Output 500mA at 12 VDC <br /> module is included with the XR5SL. Alarm Output 1.5 Amps at 12 VDC(XR5FC) <br /> Smoke Output 100mA at 12 VDC(XR5FC) <br /> One Man Walk Test Feature Annunciator Outputs(4) 50mA each at 12 or 24 VDC <br /> You can now conduct one-man tests of the system and all <br /> connected devices using the Walk Test feature. A fire Enclosure 20 gauge cold rolled steel(Gray) <br /> technician simply enters an access code into the keypad Dimensions 12.5"H x 9.5"w x 2.75"D <br /> and the XR5 panels automatically enter the test mode. weight 4 lbs.with panel <br /> Each time a zone is tripped during the test,the bell rings for <br /> two seconds and a Sensor Reset is automatically performed <br /> to reset any latched detectors.When the test is completed, HIP <br /> the results are displayed at the keypad and can be sent to <br /> the central station. - <br /> 2841 E.Industrial Drive Springfield,MO 65802-6310 800-641-4282 Digital Monitoring Products <br /> LT-0298 (7/96) <br />