Laserfiche WebLink
377 Trouble Annunciator Module <br /> MAIN BACKUP MODELXR5 <br /> ■■ Sil � cusrs'r a siconDaEET Panel Reset <br /> ence/Reset <br /> ❑� 0 <br /> Heatley Silence/Reset <br /> Telephone Connections Button O <br /> J10 Trouble Annunciator Header IIJ <br /> D <br /> Direct connect to unswitched Relay Sockets for Optional <br /> 120 VAC 60 Hz O Form C Outputs on J11 <br /> O <br /> DMP transformerJpJ �o Y <br /> Model 320 [ 3 <br /> 16.5 VAC 40VA . - <br /> wire-in c c e, Eu mrc ED EL ae 'Ls z'i., m-zi',z e- n, Zi i'a, d<. z'9 <br /> 4 <br /> Wtj <br /> Output Header J12 <br /> 3 Z ' 3.31,a Four Open Collector Outputs. <br /> g o w i ZONE 5 50mA at 30 VDC resistive <br /> Secondary Power SupplyW <br /> 1.2 Amps max,charging current. ID Do <br /> z z z z ZONE1 <br /> Output 1 Output 2 <br /> CDld water Pipe 2 2 7 2 Output Header J11 <br /> Bell Circuit Earth cmuna d d d a Two Form C(SPOT)Outputs. <br /> 1.5 Amps at 12 VDC O O O c7 <br /> 3.31,11 11 <br /> oae a ZONE 2 <br /> M d 1308 <br /> ZONE 4 <br /> LO Red <br /> Auz.Pawer Black <br /> Model866 Power <br /> ClGround <br /> ass a(Style w) AI"'"I"Pm Up to 100mA of current is available for sDDewiemD <br /> Notification Circuit Module Be01npot 4-wire smoke detectors from terminal 6. Reiey <br /> 37mA at 12 VDC Bell ou[Pos �-supervised Circuit <br /> Bell Out Neq <br /> Bell Trouble <br /> Bell Trouble <br /> 3.3k R <br /> ZONE 3 Model 692F Model 670 <br /> 40mA at 8 to 16 VDC. 1 OOmA at 8 to 16 VDC. <br /> Keypads -- - - - - - - <br /> 0 0 0 0 <br /> Model 690 <br /> 100mA at 8 to 16 VDC. 0000 0000 0000 <br /> �000 <br /> 0000 0000 0000 <br /> OOOO upen5a 12 aDxirary OOOO <br /> current at 12 VDC from <br /> 0000 Terminan. 0000 <br /> 16-Character Keypads <br /> 32-Character Keypads 10 Zone LED Keypads <br /> XR5FC System Configuration Diagram <br /> Remote Programming Fire Retard allows a programmable time of up to 250 <br /> You can remote program the XR5 panels using Remote seconds for waterflow detection. This eliminates the need <br /> AccessTM programming software from DMP to load for additional mechanical delays at the flowswitch. <br /> programs into new accounts or make copies of existing <br /> programs. You can also upload the 16 event memory for AC or DC Power Input <br /> diagnostic purposes. The XR5 panels operate on either 16 VAC from a wire-in <br /> transformer or 24 VDC from a main Fire Alarm Control <br /> Built-in Programmer Panel (FACP). This allows the panels to be used as stand <br /> The XR5 panels also contain an internal English text alone communicators or FACPs. When powered from the <br /> Programmer that allows installers and service technicians 24 VDC input of a larger FACP,the panels can operate as <br /> to easily program and testthe panels from an alphanumeric slave communicators with 12 VDC auxiliary output capability. <br /> keypad connected to the remote annunciator bus. <br /> Annunciator Outputs <br /> Powerful False Alarm Reduction Features Four open collector annunciator outputs and two optional <br /> The built-in false alarm reduction features include Cross Form C dry contact relays are provided on the XR5 panels <br /> Zoning, Fire Verification, and Fire Retard. Cross zoning for a variety of remote control and annunciation applications. <br /> allows multiple zones to report alarms only when two or The outputs can be used to indicate general fire alarm and <br /> more are tripped. Should just one zone trip, a zone fault trouble indications as well as individual zone conditions. <br /> report is sent to the central station. <br /> Listings and Approvals <br /> Fire Verification provides a 120 second window during The XR5FC and XR5SL panels are UL listed for Central <br /> which a smoke detector can trip, be automatically reset, Station DACT and Remote Station Signaling. The XR5FC <br /> and then must trip a second time before an alarm is <br /> indicated.A single trip on the zone sends just a zone fault is also listed for Local Protective Signaling when using the <br /> g65 or 866 Notification Circuit Modules. <br /> report to the central station. <br /> D igit al Monitoring Products <br /> 2841 E. Industrial Drive Springfield, MID 65802-6310 800-641-4282 <br />