Laserfiche WebLink
Addressable Contact Input Effective: January 2008 <br /> Device <br /> F-74-214 <br /> FEATURES <br /> • Monitors N/O Or N/C Unpowered Contacts <br /> • Full Digital Communications <br /> • Signaling-line-circuit Connections: SmartOne <br /> • Class A, Style 6 or 7 or "'11M.Al,we W <br /> • SEE NSTµ Td07 m m <br /> Class B,Style 4 „ <br /> M)li°y SI°5 <br /> • Class B,Style B Initiating Device Circuit "AW"SEAL,,E,,, <br /> Remote-led Output ED�SEpy�E SEND TD u^ <br /> .W yE�wAI."C. Gam-V <br /> • ASMlANO,AA <br /> A• Alarm Test From Compatible Control Unit Keypad °•'E°EMAL,DEACTW, <br /> • UI Listed/FM Approved „w•,,,L,."o <br /> wLAwirtD u` �� <br /> n .- <br /> DESCRIPTION <br /> The SmartOne®Addressable Contact Input Device (AI) <br /> is an intelligent field device with its own microprocessor, <br /> 4K of memory and electronics necessary to interface N/ SUPERVISION <br /> O or N/C unpowered contacts to the compatible control The Al continuously monitors the integrity of the follow- <br /> unit system. All of the electronics are contained in a <br /> high-impact polymer case, creating a very small and ing: <br /> durable device for installation. Continuity of supervised wiring <br /> Two types of AI's are available: an AI/NC for interfacing Power/Communications circuit voltage <br /> to normally-closed devices and an AI/NO for interfacing Internal power supply <br /> to normally-open devices. The Al may be located up to Memory data <br /> 2,500 feet from the monitored device with #18 AWG wir- Faulty entering of data into Al memory <br /> ing. An end-of-line-resistor is required for supervision of FAILSOFT OPERATION <br /> the wiring to the device. <br /> Should there be a failure in the communication link <br /> FIELD PROGRAMMING between the Al and the microprocessor that controls its <br /> System address, owner location message and reporting signaling line circuit, the Al is capable of reporting a Zone <br /> type are programmable via the compatible control unit Alarm for the signaling line circuit and initiating a general <br /> configuration software program. alarm signal. During a general alarm, all outputs pro- <br /> The System address is a 4-digit number that uniquely grammed for failsoft operation will activate. <br /> identifies each device. The owner location message is a STATUS LED <br /> 40-character, alpha numeric message that describes the A remote status LED may be connected to the Al. A slow <br /> location of the device. The reporting type is assigned to flash rate of approximately nine seconds indicates a nor- <br /> the Al depending on the functionality of the device being mal condition, a two-second flash rate indicates alarm <br /> monitored. and no flash indicates a trouble condition. <br />