3003 W CASINO RD BLDG 40-92 2024-06-12
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-92
>
3003 W CASINO RD BLDG 40-92 2024-06-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2024 11:13:42 AM
Creation date
5/7/2024 11:23:16 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-92
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WIRING DIAGRAM SPECIFICATIONS <br /> Typical N.O.Initialing Input Voltage: 16.5 -27.5 VDC <br /> Devices Standby Current: 450 pA Max <br /> Alarm Current: 450 pA Max <br /> See Notes:1,2,and 4 Max. No. Of Devices per <br /> Communication Circuit: 255 (Will support all <br /> See Note3 devices in alarm simul- <br /> SLC Line <br /> ( EOL <br /> (10K Resistor) taneously) <br /> SLC Line <br /> In (' 0 °u1 Operating Temperature: -31 - 151�F (-35 -6&C) <br /> See Note 3 Typical N.0Devices.Supervisory 0 — 95% RH <br /> Remote LED <br /> (Optional) LED Pulse Modes <br /> See Note 7 Normal: 9 second interval <br /> L Trouble: LED is off <br /> o e Alarm: 2 second interval <br /> ®® ®®®® (1 OK Resistor) <br /> E° <br /> NOTES ORDERING INFORMATION <br /> 1. Maximum 25 Q resistance per conductor/50 Q per Part Number Description <br /> circuit. 70-407008-001 Addressable Contact Input <br /> 2. Max. #14 AWG (1.5 mm2)wire. Device N.O. <br /> Min. #18 AWG (0.75 mm2)wire. 70-407008-002 Addressable Contact Input <br /> 3. Refer to Control Panel Manual for wiring specifica- Device N.C. <br /> tion. 70-411001-005 Package of 10 End-of-Line <br /> 4. Maximum 10 VDC @ 1 mA. Resistors <br /> 5. All wiring is power limited and supervised. <br /> 6. This module will not support 2-wire smoke detec- <br /> tors. ARCHITECTURAL/ENGINEERING <br /> 7. Rating of LED circuit: 26 VDC Max., 7mA Max. If SPECIFICATIONS <br /> not used leave terminals open circuit. For specifications request a copy of the Architectural/ <br /> 8. N/O and N/C initiating device circuits are NFPA Engineering Specification Disk: Available from Kidde- <br /> Class B/Style B. Fenwal Inc. Marketing Department. <br /> 9. Al N/C is intended for non-fire applications. <br /> ALARM TEST <br /> Any or all Als can be tested by command from the com- <br /> patible control unit. Results of the test may be printed out <br /> at the system printer. <br /> INSTALLATION <br /> The Al can be mounted in a North American 2-1/2-in. (64 <br /> mm)deep, 1-gang box, or standard 4-in. square box, <br /> 1-1/2-in. (38 mm) deep with cover. The terminal block <br /> will accept#14, 16 and 18 AWG wire (1.5 mm2, 1.0 mm2, <br /> 0.75 mm2). <br /> SmartOne°is a registered trademark of Kidde-Fenwal,Inc. <br /> This literature is provided for informational purposes only. KIDDE-FENWAL,INC. 0 <br /> assumes no responsibility for the product's suitability for a particular application.The prod- <br /> uct must be properly applied to work correctly. <br /> If you need more information on this product,or if you have a particular problem or ques- <br /> tion,contact KIDDE-FENWAL,INC.,Ashland,MA 01721.Telephone:(508)881-2000. <br /> KIDDE-FENWAL INC. <br /> F-74-214 Rev AD ©2008 Kidde-Fenwal Inc. Printed in USA 400 MAIN STREET,ASHLAND,MA 01721 <br /> TEL:(508)881-2000 FAX:(508)881-8920 <br /> www.Kidde-Fenwal.com <br />