My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-92 2024-06-12
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-92
>
3003 W CASINO RD BLDG 40-92 2024-06-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2024 11:13:42 AM
Creation date
5/7/2024 11:23:16 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-92
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIGURE S.MULTIPLE FAN SHUTDOWN [12.S]DETECTOR CLEANING PROCEDURES <br /> (INTERCONNECTION OF D4120'S): Notify the proper authorities that the smoke detector system is undergoing <br /> 0120 VAC D4120 0120 VAC D4120 maintenance,and that the system will temporarily be out of service. Disable <br /> 0 0 the zone or system undergoing maintenance to prevent unwanted alarms and <br /> 10 Q 10 0 possible dispatch of the fire department. <br /> 0 (a 0 18 [12.5.1]ALARM TESTS <br /> 19 ® 19 ® la. Test/Reset Button-Press and hold the test button located on the power <br /> 0 (D0 Q 50 <br /> INT/AUX- 6 C,AUXA INT/AUX- 6 C,AURA DET. board cover for at least 2 seconds. <br /> 12 INT+ 16 NC,AUXA 12 INT+ 16 NC,AUXA MAX. OR <br /> 1s a s ,a lb. M02-04-00 Magnet Test(Magnet sold separately) -Place the painted sur- <br /> 11Q 11 O <br /> ® 0 s face of the magnet onto the MAGNET TEST location on the sensor cover <br /> Q Q 0 0 of unit(Figure 1). <br /> O ® 0 ® OR <br /> DETECTOR 1 DETECTOR 2 lc. Remote Test Accessory-See list on page 1. <br /> SYSTEM CONTROL SYSTEM CONTROL The red alarm LED on the sensor and the power board should latch on, <br /> POWER,FAN POWER,FAN as should any accessories (i.e.RA400Z/RA100Z,RTS451/RTS151).Verify <br /> CONTROL OR CONTROL OR system control panel alarm status and control panel execution of all in- <br /> THERMOSTAT THERMOSTAT H0552-00 <br /> tended auxiliary functions(i.e fan shutdown,damper control,etc.). <br /> FIGURE 9.MULTIPLE FAN SHUTDOWN(INTERCONNECTION OF D4120 2. The detector must be reset by the system control panel,front cover Test/ <br /> TO DH100ACDC): Reset button,or remote accessory. <br /> DH100ACDC DH100ACDC 3. To reset using the Test/Reset button on the power board cover simply <br /> Press and release. <br /> 4. Verify airflow test per Section 7 has been performed. <br /> [12.5.2]SMOKE RESPONSE TESTS <br /> Da12o To determine if smoke is capable of entering the sensing chamber, visually <br /> identify any obstructions. Plug the exhaust and sampling tube holes to pre- <br /> vent ducted air from carrying smoke away from the detector head,then blow <br /> �Nl smoke such as cigarette, cotton wick, or punk directly at the head to cause <br /> an alarm.REMEMBER TO REMOVE THE PLUGS AFTER THIS TEST,OR THE <br /> DETECTOR WILL NOT FUNCTION PROPERLY. <br /> D4120 [12.5.3]SMOKE ENTRY USING AEROSOL SMOKE <br /> H0617-00 This test is intended for low-flow systems (100-500 FPM). If the air speed is <br /> greater than 500 FPM,use a conventional manometer to measure differential <br /> [11.1]IMPORTANT INTERCONNECTION NOTES: pressure between the sampling tubes,as described in Section 7.1. <br /> • When using the interconnect feature, all interconnected units must be Drill a'/a inch hole 3 feet upstream from the duct smoke detector.With the air <br /> powered using the same independent supply. handler on,measure the air velocity with an anemometer.Air speed must be <br /> • Polarity must be maintained throughout the interconnect wiring. at least 100 FPM.Spray aerosol smoke*into the duct through the'A inch hole <br /> Connect the INT+ terminal on unit 1 to the INT+ terminal on unit 2 for five seconds.Wait two minutes for the duct smoke detector to alarm.If the <br /> and so on. Similarly, connect the INT/AUX- terminal on unit 1 to the duct smoke detector alarms, air is flowing through the detector. Remove the <br /> INT/AUX-terminal on unit 2 and so on. duct smoke detector cover and blow out the residual aerosol smoke from the <br /> • Up to 50 D4120 units may be interconnected. chamber and reset the duct smoke detector.Use duct tape to seal the aerosol <br /> • Up to 10 DH100ACDC units may be interconnected. Please note that smoke entry hole. <br /> each of the 9 DH100ACDC units interconnected can be substituted by *Aerosol smoke can be purchased from Home Safeguard Industries at home- <br /> three D4P120 units. Therefore, when using the interconnect feature a safeguard.com, model 25S Smoke Detector Tester, and Chekkit Smoke De- <br /> single DH100ACDC can drive either 9 DH100ACDC's or 27 D4120 units. tector Tester model CHEK02 and CHEK06 available from SDi. When used <br /> NOTE:Alarm can be reset only at the initiating device and not at the devices properly, the canned smoke agent will cause the smoke detector to go into <br /> interconnected. alarm. Refer to the manufacturer's published instructions for proper use of <br /> [12]VERIFICATION OF OPERATION the canned smoke agent. <br /> [12.1]FIELD SELECTABLE SETTINGS ACAUTION <br /> Verify dip switch settings as per Table 2 on Page S. <br /> Canned aerosol simulated smoke(canned smoke agent) formulas will vary by <br /> [12.2]POWERING THE UNIT manufacturer. Misuse or overuse to these products may have long term ad- <br /> Apply 24 VDC power to 9 and 10 terminals on the D4P120 or apply 120 VAC on verse effects on the smoke detector. Consult the canned smoke agent manufac- <br /> terminals named 120VAC.See Figure 7 and electrical specifications for details. turer's published instructions for any further warnings or caution statements. <br /> [12.3]PERFORM DETECTOR CHECK <br /> VERIFY STANDBY AND TROUBLE TEST per Table 3 on page 8.The use of a [12.6]INSTALL THE COVER <br /> remote accessory for visible indication of power and alarm is recommended. Install the covers making sure that the cover fits into the base groove.Tighten <br /> NOTE:If an instantaneous tamper delay is selected a trouble may be indicated the seven screws that are captured in the covers. <br /> with the cover installed. [13]DETECTOR CLEANING PROCEDURES <br /> [12.4]SENSITIVITY VERIFICATION Notify the proper authorities that the smoke detector system is undergoing <br /> The sensitivity of the sensor is confirmed to be operating within its allowable maintenance,and that the system will temporarily be out of service. Disable <br /> range each time the sensor and power board LEDs blink green every 5 sec- the zone or system undergoing maintenance to prevent unwanted alarms and <br /> onds.Note in a maintenance condition the sensor LEDs will blink red every 5 possible dispatch of the fire department. <br /> seconds and power board will blink amber as depicted in Table 3 on page 8. <br /> The maintenance condition indicates that the sensor is operating outside its <br /> original factory preset sensitivity and shall be cleaned or replaced.See Section <br /> 9 for reference.This is a valid UL test. <br /> 6 I56-2967-008R <br /> 06-10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.