3003 W CASINO RD BLDG 40-92 2024-06-12
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-92
>
3003 W CASINO RD BLDG 40-92 2024-06-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2024 11:13:42 AM
Creation date
5/7/2024 11:23:16 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-92
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 3.DETECTOR STATUS INDICATION <br /> NOTE: There are two LED's on the Power board D4P120, each indicating the Status of the two sensors connected. <br /> When there is only one sensor connected, LED2 will remain off. <br /> LED Status <br /> Status Description Sensor Power Board Status of Relays <br /> D4S D4P120 <br /> At power-up or reset at the panel,the <br /> sensor will take approx 35 seconds Alternating Supervisory relay:Terminals 3 and 14 are closed. <br /> to initialize.Also occurs if the sensor RED Blink every 5 Green/amber Alarm Relay:Terminals 4 and 5 are open. <br /> has been removed and restored in seconds every 1 second Aux Relay does not switch states:Terminals 6 and 16 are closed,Terminals 8 and 18 are closed <br /> Sensor the base in the sensor housing. <br /> Initialization <br /> Sensor is missing during the seven Alternating Supervisory relay:Terminals 3 and 14 are closed <br /> minute tamper Delay,if selected. Off Green/amber Alarm Relay:Terminals 4 and 5 are open. <br /> every 1 second Aux Relay does not switch states:Terminals 6 and 16 are closed,Terminals 8 and 18 are closed <br /> Sensor D4S is outside it's UL Supervisory relay:Terminals 3 and 14 are closed. <br /> Maintenance approved sensitivity limits and needs RED Blink every 5 Amber Blink Alarm Relay:Terminals 4 and 5 are open. <br /> to be cleaned or replaced. seconds every 5 seconds Aux Relay does not switch states:Terminals 6 and 16 are closed,Terminals 8 and 18 are closed <br /> .Unit loses Power Off Off <br /> .Cover Tamper Delay times out Green Blink every 5 Amber solid <br /> seconds <br /> .Wiring Problems between the Off Amber solid <br /> Sensor and the Power Board <br /> .Mismatch between the number of <br /> sensors connected and the Dip Supervisory relay:Terminals 3 and 14 are open. <br /> Switch setting Alarm Relay:Terminals 4 and 5 are open. <br /> Trouble LED1 Green Aux Relay does not switch states with no shutdown on Trouble selected: <br /> Green blink every 5 blink every 5 Terminals 6 and 16 are closed.Terminals 8 and 18 are closed. <br /> 1 sensor connected,2 selected seconds on first seconds Aux Relay Switches states with shutdown on Trouble selected: <br /> sensor. LED2 Amber Terminals 6 and 16 are open,Terminals 8 and 18 are open <br /> No second sensor. solid <br /> Green blink every 5 LED1 Green <br /> seconds on first blink every 5 <br /> 2 sensors connected,l selected sensor. seconds <br /> LED's off on second LED2 Amber <br /> sensor isolid <br /> Supervisory relay:Terminals 3 and 14 are closed <br /> Alarm Unit detects smoke Solid Red Solid Red Alarm Relay:Terminals 4 and 5 are closed. <br /> Aux Relay switches states:Terminals 6 and 16 are open,Terminals 8 and 18 are open <br /> Unit has Power and it is not in Green Blink every 5 Green Blink Supervisory relay:Terminals 3 and 14 are closed <br /> Standby initialization,Trouble,Maintenance or Alarm Relay:Terminals 4 and 5 are open. <br /> Alarm. seconds every 5 seconds Aux Relay does not switch states:Terminals 6 and 16 are closed,Terminals 8 and 18 are closed <br /> NOTE: If any other visual indication is noted contact System Sensor technical support at 1-800-SENSOR2. <br /> Please refer to insert for the Limitations of Fire Alarm Systems <br /> THREE-YEAR LIMITED WARRANTY <br /> System Sensor warrants its enclosed product to be free from defects in materials and TX 79936,USA.Please include a note describing the malfunction and suspected cause <br /> workmanship under normal use and service for a period of three years from date of of failure.The Company shall not be obligated to replace units which are found to be <br /> manufacture.System Sensor makes no other express warranty for the enclosed product. defective because of damage,unreasonable use,modifications,or alterations occurring <br /> No agent,representative,dealer,or employee of the Company has the authority to in- after the date of manufacture.In no case shall the Company be liable for any consequen- <br /> crease or alter the obligations or limitations of this Warranty.The Company's obligation tial or incidental damages for breach of this or any other Warranty,expressed or implied <br /> of this Warranty shall be limited to the replacement of any part of the product which is whatsoever,even if the loss or damage is caused by the Company's negligence or fault. <br /> found to be defective in materials or workmanship under normal use and service during Some states do not allow the exclusion or limitation of incidental or consequential dam- <br /> the three year period commencing with the date of manufacture.After phoning System ages,so the above limitation or exclusion may not apply to you.This Warranty gives you <br /> Sensor's toll free number 800-SENSDR2 (736-7672)for a Return Authorization number, specific legal rights,and you may also have other rights which vary from state to state. <br /> send defective units postage prepaid to:Honeywell,12220 Rojas Drive,Suite 700,El Paso <br /> 8 I56-2967-008R <br /> ©2016 System Sensor.06-10 <br />