Ms. Melissa Martorano <br /> Ware Malcomb <br /> Plan Check Number: B2304-062, First Building Review <br /> April 19, 2023 <br /> Architectural <br /> 1. Sheet I000 specifies the Construction Type as "II-B". The type should be"V-B" based on a <br /> review of the available records. Alternatively, documentation should be submitted <br /> substantiating the"II-B"classification. See IBC Sections 602.1, 602.2, and 602.5. <br /> a. RESPONSE: The building type has been updated to reflect V-B on the Title Sheet, <br /> I000. <br /> 2. The north arrow on the plans points upward on the sheets. The Plan North direction should be <br /> oriented to point right. See IBC Section 107.2.1. <br /> a. RESPONSE: The North Arrow has been updated on all views to be oriented to point <br /> right. <br /> 3. Doors 101E, 131, and 138 should be reviewed to verify they provide the required minimum <br /> latch-side clearance. The minimum clearance should be specified at each location. See IBC <br /> Section 1101.2 and ICC A117.1-09 Figure 404.2.3.2. <br /> a. RESPONSE: Doors 101E, 131, and 138 have all been reviewed and verified that they <br /> do provide the minimum latch-side clearance. This has been shown on the plans <br /> indicated with new dimensions on each of the doors. <br /> 4. The project involves a Level 3 Alternation as defined by IEBC Section 604.1. The building <br /> exterior envelope should comply with the requirements for new construction per WSEC Section <br /> C402. Details for the components of the exterior envelop should be included. Note that <br /> portions of the building may not be feasible to reconfigure, including but not limited to slab <br /> insulation and thermal isolation per WSEC Section C402.2.6. Additional insulation may be <br /> provided complying with Section C402.1.5 in lieu of modifying these components. <br /> a. RESPONSE: This comment has been addressed with the addition of the furring wall <br /> detail and legend. The legend states that"Existing exterior wall with new furring <br /> shall be provided with R13 insulation with one (1) layer of 5/8" gypsum board to 6" <br /> above ceiling and continue insulation (only) to deck above. The furring shall continue <br /> above and below windows which are not full height gypsum board to wrap window <br /> frame at sill, jamb, and head. Our vertical fenestration area (not including opaque <br /> doors and opaque spandrel panels) equals 13.6 percent of the gross above-grade <br /> wall area, meeting the requirement not exceeding 30 percent. <br /> 5. Continuing with the previous comment, the project involves removing finishes and exposing the <br /> cavities for the exterior furred walls and ceiling/roof. Insulation should be specified in the <br /> exposed cavities as required by WSEC Sections C402 and C503.1. See IBC Section 101.4.7 and <br /> IEBC Section 907.1. <br /> a. RESPONSE: In addition to the above noted items, the addition of keynote number <br /> 406, on sheet I120 states that there shall be insulation provided above ceiling, <br /> within the building attic space. <br /> O3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 3 <br />