My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5130 EVERGREEN WAY COMMUNITY MEDICAL SERVICES 2025-05-09
>
Address Records
>
EVERGREEN WAY
>
5130
>
COMMUNITY MEDICAL SERVICES
>
5130 EVERGREEN WAY COMMUNITY MEDICAL SERVICES 2025-05-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2025 9:35:43 AM
Creation date
5/7/2024 11:31:44 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5130
Tenant Name
COMMUNITY MEDICAL SERVICES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
258
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Melissa Martorano <br /> Ware Malcomb <br /> Plan Check Number: B2304-062, First Building Review <br /> April 19, 2023 <br /> Structural <br /> 1. The project included demolition of the interior walls. The east-west wall extending from the <br /> building corner, separating the north and south portions of the building, appears to be a <br /> structural masonry wall. See IBC Sections 101.4.7, 107.2.1, 1603.1, 1604.1, 1604.2, 1604.4, <br /> and 1613.1, and IEBC Section 806. The following comments should be addressed: <br /> a. The wall appears to be load bearing and originally supported part of the original roof. A <br /> new roof was constructed circa 2010 under Permit No. B1007-047. However, it is not clear <br /> that the entire existing roof was demolished; portions may remain. Structural modifications <br /> may be required. <br /> b. The wall appears to be part of the lateral system. Removal of the wall reduced the capacity <br /> of the vertical lateral system. In addition, this will increase the span and loads in the roof <br /> diaphragm. Additional modifications to the diaphragm at the re-entrant building corner will <br /> also be required. See ASCE 7-16 Chapter 12. <br /> I. RESPONSE: Structural engineering site visit was completed and concluded <br /> that this wall was not a lateral wall, and just had structural columns to <br /> support the roof concealed within it. Structural drawings and calculations <br /> have been provided to address the structural re-work required to suit the <br /> new wall layout. <br /> 2. Continuing with the previous two comments, structural drawings specifying modifications should <br /> be included in the drawing set. The drawings should be sealed and signed by a professional <br /> engineer licensed in the state of Washington. Calculations substantiating the design should be <br /> submitted for review. See IBC Section 107.1 and RCW 18.43. <br /> a. RESPONSE: Structural Drawings and Calculations have been provided with this <br /> resubmittal. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Drew Martin, P.E., S.E. <br /> Associate Engineer/ Commercial Plans Examiner <br /> (425)257-8813 <br /> dmartin@everettwa.gov <br /> S:\BMartin\2023\B2304-062_R1.docx <br /> ( ) 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.