My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10111 9TH AVE W EMERALD COURT APARTMENTS 2024-06-13
>
Address Records
>
9TH AVE W
>
10111
>
EMERALD COURT APARTMENTS
>
10111 9TH AVE W EMERALD COURT APARTMENTS 2024-06-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2024 11:19:30 AM
Creation date
5/14/2024 4:07:30 PM
Metadata
Fields
Template:
Address Document
Street Name
9TH AVE W
Street Number
10111
Tenant Name
EMERALD COURT APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' • • <br /> Architecture <br /> Interior Design <br /> 135 Lake Street South <br /> Suite 250 <br /> Kirkland,WA 98033 <br /> KILBURN 206-682-5211 Tel <br /> aniFcs tic 206-682-1403 Fax <br /> 15 December 2022 (DI <br /> I. © <br /> EIVED <br /> City of Everett—Permit Services <br /> Attn: Drew Martin DEC 2 7 2022 <br /> 3200 Cedar Street <br /> Everett,WA 98201 CITY OF EVERETT <br /> Re: Correction Notice#2—BUILDING REVIEW Permit Services <br /> Project#B2208-006—10111 9th Avenue W. <br /> Mr,Martin, <br /> The following is our responses to your correction notice#2 dated October 20,2022: <br /> Architectural <br /> Fire Protection: <br /> 4. Correction#4: <br /> The existing bedroom is being converted to additional space for the west lobby. Wall Type <br /> "W2" providing a one-hour rating is specified only at the door infill. The following comments <br /> should be addressed: <br /> a. The wall type should be specified along all walls separating the dwelling from the lobby. <br /> See IBC Section 420.2. <br /> b.The drawings should include penetration details for the walls separating the dwelling and <br /> the lobby. See IBC Section 714.4. <br /> c. Wall Type "W2" indicates an STC rating of 30 to 34. However, the listed assembly GA <br /> File No. WP3605 does not indicate this rating. The walls separating the dwelling and the <br /> lobby are required to have a minimum rating of 50. See IBC Section 1206.2. <br /> Response#4: <br /> See sheet A-1.1 for wall types specified on detail 2, as well as, revised wall type "W2" to <br /> indicated STC rating of 50 minimum <br /> a. The new 1-hr rating and,wall type is specified on 2/A-1.1,see also"wall key"and "wall <br /> type"on right of sheet on A-1.1. <br /> b. See penetration details on sheet A-1.1. <br /> c. See updated GA File no.which reflects STC min 50 listed on wall type"W2". <br /> 5. Correction#5: <br /> The proposed construction will require repair to the horizontal assembly. The assembly <br /> requires a minimum one-hour construction. The required construction should be determined <br /> based on the configuration of the building, and a detail included in the construction drawings. <br /> See IBC Section 420.2 and Table 601. <br />
The URL can be used to link to this page
Your browser does not support the video tag.