My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10111 9TH AVE W EMERALD COURT APARTMENTS 2024-06-13
>
Address Records
>
9TH AVE W
>
10111
>
EMERALD COURT APARTMENTS
>
10111 9TH AVE W EMERALD COURT APARTMENTS 2024-06-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2024 11:19:30 AM
Creation date
5/14/2024 4:07:30 PM
Metadata
Fields
Template:
Address Document
Street Name
9TH AVE W
Street Number
10111
Tenant Name
EMERALD COURT APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• s <br /> Response#5: <br /> See sheet A-1.1 wall type"C1"for repair to 1-hr minimum construction for horizontal assembly. <br /> Structural <br /> General: <br /> 1. Correction#1: <br /> The project includes modifications to the structural systems. Structural drawings sealed and <br /> signed by a professional engineer licensed in the state of Washington are required. See IBC <br /> Section 107.1 and RCW 18.43. <br /> Response#1: <br /> Shear walls(and door location)to remain unchanged. <br /> Foundations: <br /> 2. Correction#2: <br /> The proposed project includes modifications that may require the construction of new <br /> foundations. A foundation plan may be required. Calculations substantiating the new <br /> foundations should be submitted for review. See IBC Sections 107.2.1, 1603.1, 1604.1, and <br /> 1604.4. <br /> Response#2: <br /> Shear walls to remain unchanged. <br /> Gravity System: <br /> 3. Correction#3: <br /> The proposed project includes walls that are load bearing. Structural framing plans are <br /> required. Calculations substantiating the modifications to the load path should be submitted <br /> for review. See IBC Sections 107.2.1, 1603.1, 1604.1,and 1604.4. <br /> Response#3: <br /> Shear walls to remain unchanged. <br /> Lateral System: <br /> 4. Correction#4: <br /> The proposed project includes demolition of a lateral shear wall. Note that this wall also serves <br /> as a load-bearing wall for the stories above. Structural framing plans are required. <br /> Calculations substantiating the redistributed loads to the remaining lateral system should be <br /> submitted for review. See IBC Sections 107.2.1, 1603.1, 1604.1, 1604.4,and 1613.1. <br /> Response#4: <br /> Shear walls to remain unchanged. <br /> Miscellaneous: <br /> 5. Correction#5: <br /> The proposed project includes construction of new exterior walls. The wall construction is <br /> required to comply with the requirements of IBC Section 2304.12.1.5. <br /> '13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.