Laserfiche WebLink
Ms. Cassandra Cheatham <br /> Kilburn Architects, LLC <br /> Plan Check Number: B2208-006, First Building Review <br /> August 12, 2022 <br /> the north side. Details for its construction should be specified. The door must comply with the <br /> minimum opening requirements or be eliminated. See IBC Sections 1005.3.2, 1010.1.1, <br /> 1011.11, 1014.2, and 1014.6. <br /> Accessibility: <br /> 8. The project proposes converting the single bedroom unit to a studio unit. The original building <br /> design included Type A units as required by IBC Section 1107.6.2.2.1. The provided number <br /> and distribution of units may be impacted by the proposed design. An analysis should be <br /> performed to verify that the minimum number and distribution of units has been maintained. <br /> Energy: <br /> 9. The proposed project includes modifications to the exterior envelope of the building. Thermal <br /> performance ratings should be specified for each type of component. See WSEC Section <br /> C503.1. <br /> Structural <br /> General: <br /> 1. The project includes modifications to the structural systems. Structural drawings sealed and <br /> signed by a professional engineer licensed in the state of Washington are required. See IBC <br /> Section 107.1 and RCW 18.43. <br /> Foundations: <br /> 2. The proposed project includes modifications that may require the construction of new <br /> foundations. A foundation plan may be required. Calculations substantiating the new <br /> foundations should be submitted for review. See IBC Sections 107.2.1, 1603.1, 1604.1, and <br /> 1604.4. <br /> Gravity System: <br /> 3. The proposed project includes walls that are load bearing. Structural framing plans are <br /> required. Calculations substantiating the modifications to the load path should be submitted for <br /> review. See IBC Sections 107.2.1, 1603.1, 1604.1, and 1604.4. <br /> Lateral System: <br /> 4. The proposed project includes demolition of a lateral shear wall. Note that this wall also serves <br /> as a load-bearing wall for the stories above. Structural framing plans are required. Calculations <br /> substantiating the redistributed loads to the remaining lateral system should be submitted for <br /> review. See IBC Sections 107.2.1, 1603.1, 1604.1, 1604.4, and 1613.1. <br /> 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 4 <br />