My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5801 S 2ND AVE 2022 Plans 2024-05-24
>
Address Records
>
S 2ND AVE
>
5801
>
Plans
>
5801 S 2ND AVE 2022 Plans 2024-05-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 1:41:29 PM
Creation date
5/16/2024 1:14:40 PM
Metadata
Fields
Template:
Address Document
Street Name
S 2ND AVE
Street Number
5801
Permit
B2201-024
Year
2022
Notes
CONSTRUCT NEW ADDITIONAL DWELLING UNIT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table M1507.3.3(1) <br />Continuous Whole -House Mechanical Ventilation System Airflow Rate ReauirPmentc <br />Dwelling Unit <br />Floor Area (square <br />feet) <br />0-1 <br />NUMBER OF BEDROOMS <br />2-3 4- 5 6-7 <br />7 <br />Airflow in CFM <br />< 1.500 <br />30 <br />45 <br />60 <br />75 <br />90 <br />1,501 -3,000 <br />45 <br />60 <br />75 <br />90 <br />105 <br />3,001 - 4,500 <br />60 <br />75 <br />90 <br />105 <br />120 <br />4,501 - 6.000 <br />75 <br />90 <br />105 <br />120 <br />135 <br />6,001 - 7,500 <br />90 <br />105 <br />120 <br />135 <br />150 <br />-7,501 <br />105 <br />120 <br />135 <br />150 <br />165 <br />Table M1507.3.3(2) <br />Intermittent Whole -House Mechanical Ventilation Rate Factorsa, b <br />Run -Time Percentage in Each <br />4-Hour Segment <br />25% <br />33% <br />50% <br />66% <br />75% <br />100% <br />Factor <br />4 <br />3 <br />2 <br />1.5 <br />1.3 <br />1.0 <br />Mini Split <br />Heat Pump <br />Attic Access <br />0 <br />d- <br />r <br />/ / I <br />Heat/AG <br />Head Unit <br />Table M1507.4 <br />Minimum Required Local Exhaust Rates <br />For One- and Two-Familv Dwellines <br />Area to Be <br />Exhausted <br />Exhaust Rates <br />Kitchens <br />100 cfm intermittent or 25 <br />cfm continuous <br />Bathrooms - <br />Mechanical exhaust <br />Toilet rooms <br />capacity of 50 cfm <br />Laundry rooms, <br />intermittent or <br />indoor swimming <br />20 cfm continuous <br />pools, and spas <br />For SI: 1 cubic foot per minute = 0.0004719 m'/s. <br />Basement venting: <br />IRC 408 <br />1 sf of venting <br />150 SF of Basement <br />997/150 = 6.65 SF Venting <br />35' <br />12-3 1 /2" 2'-3 1 /2" <br />3'-7 3/4" 5' 3'-7 3/4" 5-2 3/4" 2'-8" <br />-- —— — — — — — — — — — — T — A--- -- <br />5050DH 2530DH <br />-L 0'-5" <br />11 ' i�j'' <br />— (%r I I. <br />3068 <br />V <br />Tempered glass to be <br />installed in bathroom and <br />entry as required. <br />\ �n / <br />m m I B24R 5836 Dishwasher <br />u, <br />\\ °O / <br />\Ped r o J0 o / <br />Kilo*// Dining <br />In <br />f\ 1466 <br />r � <br />SB3031 � 563031 \ <br />/ <br />Bagoom / <br />-ll <br />cr. <br />Living Room <br />YAR <br />'5aFT <br />Basement to be unfinished <br />with only exterior access from <br />/ the rear side of the building at <br />the basement level. <br />� Smoke/CO detectors to be <br />\ installed per IRC R314/R315 <br />XZi <br />Attic Venting: <br />1 SF Venting <br />150 SF Attic Space = 6.65 SF Venting <br />Attic venting to be a combination of eave <br />!vents and roof vents. <br />0 <br />Basement access at <br />basement level <br />/4" <br />Basement to be unfinished with <br />only exterior access from the <br />rear side of the building at the <br />abasement level. <br />Smoke/CO detectors to be <br />installed per IRC R314/R315 <br />Rear deck stairs: <br />Total rise: 72 in <br />Total run: 120 in <br />Stair tread width: 36 in <br />36in x 36in landing to be <br />installed at the top and bottom <br />� <br />/ <br />New or existing`Open guards on decks more than <br />Light required 1 � have memoers spaced so that <br />Guard � Openings for required <br />.� <br />/ guards on the sides <br />of stair treads shall <br />30 inches above grade or floor below shall <br />a 4 inch diameter sphere cannot pass through. <br />Stairway Notes: <br />1. Stairways shag be not less than 3n' in width. <br />Z. Stairway risers shall be no greater than 7 14". <br />I <br />� j not allot: a 4 3r8' <br />r, <br />3. Stairway treads shall have a minimum run of tp`, <br />diameter sphere to <br />4. The length of Run and the height of Riser shall not <br />� pass through. <br />vary more than 3. B' in the run of the stair. <br />I <br />I <br />S. Stairs are required to be illuminated. <br />36` min. <br />S. Open risers are permitted if the opening is less <br />height � <br />than 4`. <br />{ <br />7. Tread nosing shall be not less than 314" but not <br />= I <br />more than 1-ti4" on stairNays vmth solid risers. <br />o � <br />I <br />Except when treads are 11" or more. <br />o <br />B. Composite materials may require additional <br />I+ <br />stringers. <br />f Deck <br />- -- <br />34-38' above <br />� <br />I <br />Less " than I nosing's <br />6ilia. <br />Handrail See Details] <br />/ <br />It[1 <br />Guard required if 10" min. ru <br />more than 30" from nosing -i- <br />I - <br />to nosing <br />� <br />I (y <br />J <br />Open risers <br />Landing same <br />36' Agin. � mdth of stairs <br />(�1 <br />Less than 4" <br />7 3.;4" max. rise�l <br />Finished tirade <br />0 <br />\ IW <br />\ I IB <br />\ l I <br />1'-3 7/16" <br />4ObbD63E2b8X 0b8D <br />S'-5172' <br />ON4 <br />in <br />Hai, !•,, �.,_ <br />the <br />Hands•.,, rn,q be nG.rn:r;G:d <br />by a newel post at a turn �"rl <br />are <br />-•.��, rf•r1 on not <br />Iless than one ` <br />jside of each Handrail ends returned <br />(continuous run of to the wall or terminated <br />1 in newel posts or safety <br />l c terminals <br />The height of iru <br />handrail is measunn: <br />vertically from the <br />sloped plane adjoining <br />the Ireal nn,inq <br />w <br />Q <br />0 <br />m <br />z <br />0 <br />a <br />U <br />w <br />0 <br />z <br />1 <br />fa <br />101- <br />L <br />_O <br />LL <br />f� <br />L <br />4-) <br />U <br />w <br />FJ� <br />� U <br />w L <br />w Q <br />2 <br />U) <br />0 <br />Q <br />Q <br />z (V <br />o U) <br />a <br />Uo <br />to 00 <br />w <br />0 L0 <br />C <br />O <br />Of <br />d <br />Co0 <br />U.]0 <br />0 <br />cc <br />0- <br />In <br />t� <br />Z_ <br />Q <br />0 <br />DATE: <br />12/21 /2021 <br />SCALE: <br />.25" = 1' <br />SHEET: <br />A-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.