VSUN400-108BM H 400 Specs HOYMILES :HM-120ON(240V)Specs Equipment Schedule Conduit&Conductor Schedule <br /> POWER MAX(PMAX): 40OW MAX INPUT VOLTAGE: 60V TYPE: CITY: DESCRIPTION: RATING: TAG QTY WIRE GAUGE DESCRIPTION CONDUIT SIZE <br /> OPEN CIRCUIT VOLTAGE(VOC): 37.2V MAX INPUT CURRENT: 20A MODULES: (53) VSUN400-108BMH 400 400 W (2) 12 AWG(90°C) AC-CABLE,COPPER(L1,L2) <br /> MAX POWER-POINT CURRENT(IMP): 12.84A NOMINAL DC INPUT VOLTAGE: 60 V INVERTERS: (13) HOYMILES HM-120014(240V) 1200 W 1 (1) 12 AWG(900C) THWN-2 COPPER-(GROUND) N/A-FREE AIR <br /> MAX POWER-POINT VOLTAGE(VMP): 31.17V MAXIMUM OUTPUT POWER: 1200 W INVERTERS: (1) HOYMILES HM-60ON(240V) 600 W (2) 10 AWG(90°C) THHN/THWN-2,COPPER-(Ll,L2) <br /> 2 3/4"PVC <br /> SHORT CIRCUIT CURRENT(ISC): 13.68A NOM.OUTPUT VOLTAGE: 240 V AC DISCONNECTS: (1) PV AC Disconnect,240V,2-Pole with 90A Fuses 100 A (1) 10 AWG(90°C) THWN-2 COPPER-(GROUND) <br /> SERIES FUSE RATING: 20A MAX OUTPUT CURRENT: 5.00 A LOAD CENTER: (1) PV LOAD CENTER,NEMA 311 RATED 125 A (10) 10 AWG(90°C) THHN/THWN-2,COPPER-(Ll,L2) <br /> 1-Phase,60 HZ,UL 1741 Listed 3 (1) 10 AWG(90°C) THWN-2 COPPER-(GROUND) ill PVC S L A R <br /> HOYMILES :HM-60ON(240V)Specs 4 (3) 4AWG(90°C) THHN/THWN-2,COPPER-(1-3,L2,NEUTRAL) 1-1/4"PVC <br /> MAX INPUT VOLTAGE: 60V (1) 6AWG(90°C) THWN-2COPPER-(GROUND) Revolution Energy Systems Inc. <br /> MAX INPUT CURRENT: 20 A 5 (3) 3 AWG(75°C) THHN/THWN-2,COPPER-(Ll,L2,NEUTRAL) 1-1/4"PVC <br /> NOMINAL DCINPUTVOLTAGE: 60V (1) 6AWG(75°C) THWN-2COPPER-(GROUND) 9981 West 190th St <br /> MAXIMUM OUTPUT POWER: 600W Unit K Mokena IL 60448 <br /> NOM.OUTPUT VOLTAGE: 240 V T: 708-995-1643 <br /> MAX OUTPUT CURRENT: 2.50 A <br /> 1-Phase,60 HZ,UL 1741 Listed <br /> STRING(1):20.OA(12 MODULES) <br /> CONNECTION AS A LINE/SUPPLY LINE SIDE TAP <br /> 690.12 RAPID SIDE CONNECTION-NEC USING INSULATION SITE INFORMATION <br /> 4 MODULES 4 MODULES 4 MODULES SHUTDOWN COMPLIANT 705.12(A) PEIRCING 705.12(A) <br /> HM-120ONHM-120014 HM-120014 <br /> EDUARDO BOTELLO&T <br /> 120/240 VAC 706 LEGION DRIVE <br /> (E)200A MAIN SERVICE PANEL TO UTILITY GRID <br /> L—_---_--L__—__—__L—___ __ t _ __ EVERETT,WA 98201 <br /> (N)240V/125A PV AC DISCONNECT <br /> STRING(2):20.OA(12 MODULES) 1-BOX PV LOAD CENTER, 100A VISIBLE,LOCKABLE, (E)200A-2� AC System Size:16.20 kW AC/16.20 kVA <br /> 1 2 NEMA 3R RATED LABELED,OPEN <br /> 240V,2-POLE DC System Size:21.20 kW DC <br /> 4 MODULES 4 MODULES 4 MODULES WITH 90A FUSES <br /> HM-12GON HM-120ON HM-120ON (E)LOADS Lat,48.0088921 <br /> = 1 = dT— Long,-122.1953944 <br /> " 1 "I "I <br /> I <br /> 2P-20A (53)VSUN400-108BMH 400 <br /> L-— ——— ——L — — L—— — i O LOADS (E) PV Modules <br /> E <br /> J-BOX 2P 20A I M) (13) HOYMILES HM-120014(240V) <br /> STRING(3):20.OA(11 MODULES) 1 2 2P-20A r—— — — —— —— -—— ——— _—— (1) HOYMILES H M-60ON(240V) <br /> 1 Inverter(s) <br /> 3 MODULES 4 MODULES 4 MODULES of <br /> HM-120014 HM-120ON HM-120ON 1 <br /> - - _ :2ZP-20AN 4 5 <br /> SNOHOMISH PUD <br /> —F-- I — <br /> L--- ————————————— 1 <br /> EXCESS PORT WILL BE CAPPED 1-BOX <br /> —�GND}— T <br /> J-BOX <br /> STRING(4):20.OA(12 MODULES) 1 2 3 (E)UTILITY METER <br /> (E)GROUNDING <br /> ELECTRODE <br /> 4 MODULES 4 MODULES 4 MODULES <br /> HM-1200N HM-120ON HM-120ON <br /> = i = 1 Vill"I 1 <br /> L--- -------------I----- -- t— — -- <br /> J-BOX <br /> STRING(5):20.OA(6 MODULES) 1 2 <br /> 4 MODULES 2 MODULES <br /> HM-120014 HM-60014 1 <br /> " 1 <br /> t VISIBLE, LOCKABLE, DRAWN BY:V. MIRAFLOR <br /> --------L___________ _ LABELED AC DISCONNECT DATE: <br /> 1-Box LOCATED WITHIN 10' 12/7/2023 <br /> 1 z OF UTILITY METER LINE DIAGRAM - PV05 <br />