My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1130 W MARINE VIEW DR MARITIME INSTITUTE 2024-06-24
>
Address Records
>
W MARINE VIEW DR
>
1130
>
MARITIME INSTITUTE
>
1130 W MARINE VIEW DR MARITIME INSTITUTE 2024-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2024 9:04:59 AM
Creation date
5/28/2024 2:56:17 PM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1130
Tenant Name
MARITIME INSTITUTE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chvac-Full Commercial HVAC Loads Calculation Program Elite Software Development,Inc. <br /> Pacific Air Control, Inc. Maritime Institute <br /> Bothell WA 98021 A Pa e 5 <br /> Air Handler#1 - RTU-1 - Total Load Summar <br /> Air Handler Description: RTU-1 Constant Volume - Proportion <br /> Supply Air Fan: Draw-Thru with program estimated horsepower of 1.07 HP <br /> Fan Input: 65% motor and fan efficiency with 2.2 in. water across the fan <br /> Sensible Heat Ratio: 0.90 --- This system occurs 1 time(s) in the building. --- <br /> Air System Peak Time: 2pm in September. <br /> Outdoor Conditions: Clg: 79° DB, 66° WB, 74.42 grains, Htg: 21' DB <br /> Indoor Conditions: Clg: 70° DB (avg.), 60% RH, Htg: 720 DB <br /> Because of the diversity in room, plenum and ventilation loads, the room sensible peak time in July <br /> at 3pm is different from the total system peak time, hence the air system CFM was computed using <br /> a room sensible load of 28,204. <br /> Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. <br /> Room Space sensible loss: 15,074 Btuh <br /> Infiltration sensible loss: 0 Btuh 0 CFM <br /> Outside Air sensible loss: 12,291 Btuh 223 CFM <br /> Supply Duct sensible loss: 1,436 Btuh <br /> Return Duct sensible loss: 718 Btuh <br /> Return Plenum sensible loss: 0 Btuh <br /> Total System sensible loss: 29,519 Btuh <br /> Heating Supply Air: 16,510 / (.999 X 1.08 X 23) = 665 CFM <br /> Winter Vent Outside Air (33.6% of supply) = 223 CFM <br /> Room space sensible gain: 27,742 Btuh <br /> Infiltration sensible gain: 0 Btuh <br /> Draw-thru fan sensible gain: 2,713 Btuh <br /> Supply duct sensible gain: 2,208 Btuh <br /> Reserve sensible gain: 0 Btuh <br /> Total sensible gain on supply side of coil: 32,664 Btuh <br /> Cooling Supply Air: 33,126 / (.999 X 1.1 X 15) = 2,009 CFM <br /> Summer Vent Outside Air (11.1% of supply) = 223 CFM <br /> Return duct sensible gain: 981 Btuh <br /> Return plenum sensible gain: 0 Btuh <br /> Outside air sensible gain: 2,209 Btuh 223 CFM <br /> Blow-thru fan sensible gain: 0 Btuh <br /> Total sensible gain on return side of coil: 3,191 Btuh <br /> Total sensible gain on air handling system: 35,854 Btuh <br /> Room space latent gain: 3,520 Btuh <br /> Infiltration latent gain: 0 Btuh <br /> Outside air latent gain: 1,409 Btuh <br /> Total latent gain on air handling system: 4,929 Btuh <br /> Total system sensible and latent gain: 40,783 Btuh <br /> Check Figures <br /> Total Air Handler Supply Air (based on a 150 TD): 2,009 CFM <br /> Total Air Handler Vent. Air (11.12% of Supply): 223 CFM <br /> Total Conditioned Air Space: 1,889 Sq.ft <br /> S:\Engineering\Chvac 8 Projects\Maritime Institute.CH8 Monday, October 23,2023,01:54 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.