Laserfiche WebLink
vNEUDORFER Hr JE <br /> s anjWGINEERS Terms and Abbreviations <br /> }��..� W W W.NEUDDRFERENGINEERS.COM <br /> Project: PAC AN. I'mnggl%'r'QM P A N Y Project: PAC Maritime Institute Change Order <br /> AC or ACU Air Conditioner or Air Conditioning Unit Dia. Diameter HVAC Heating Ventilation and Air Conditioning SAT Supply Air Temperature <br /> Act. Actual Disch. Discharge HWS Heating Water Supply S.F. Service Factor <br /> ACCU Air Cooled Condensing Unit DNL Data Not Listed HWR Healing Water Return Schedule Design data obtained from the <br /> Address Equipment designation number given mechanical cooling. HX Heat Exchanger (ached) mechanical prints'schedule of <br /> Arr Arrangement EDC Electric Duct Coil HZ Hertz,cycle per second equipment. <br /> AVG Average Controls and components that allow an I.D. Inside Diameter SCR Silcon Controlled Rectifier <br /> Amps Amperage air handler to logically utilize outdoor air In. inches Speed Controller <br /> AP Access Point for cooling as opposed to the use of Ini inches of water gauge SF Supply Fan <br /> APP. Application EDH Electric Duct Heater Kfactor Correction factor to the free area need to SFD Smoke/Fire Damper <br /> BHP Brake Horsepower EF Exhaust Fan calculate CFM. SP Static Pressure <br /> BTU British Thermal Units EG Exhaust Grille KW Kilowatts Spec(s) Specifications <br /> BTUH British Thermal Units per Hour EMCS Energy Management Control System LAT Leaving Air Temperature sq.ft. square feet <br /> CAV Constant Air Volume ERU Energy Recovery Unit LWG Low Wall Grille Submittals Submitted data on equipment <br /> CBV Calbirated Balancing Valve E.S.P. External Static Pressure LWR Low Wall Register (subs) capabilities. <br /> (Circuit Seder) Evap. Evaporator LWT Leaving Water Temperature Suct. Suction <br /> CC Cooling Coil EWT Entering Water Temperature MAU Make-up Air Hangling Unit SM Sidewall Grille <br /> CD Ceiling Diffuser FCU Fan Coil Unit MAX Maximum Flow Requirements for DDC SWR Sidewall Register <br /> CFLA Correct Full Load Amperage FD Fire Damper MBH Mega BTUs per hour(1MBH=1,000BTUH) TAB Test;Adjust;and Balance <br /> CFM Cubic Feet per Minute FH Fume Hood MIN Minimum Flow Requirements for DDC Tach Tachometer <br /> CH Chiller FLA Full Load Amperage:Maximum N/A Not Available Tech Technician <br /> CHWS Chilled Water Supply amperage a motor can draw. NIS Not Shown or Specified TSP Total Static Pressure:Difference <br /> CHWR Chilled Water Return Flow Hood Instrument that captures air and OA Outside Air between the entering and leaving <br /> Coeff. Coefficient converts the reading to CFM. OBD Opposed Blade Damper static pressure of a fan. <br /> CP Circulating Pump FPB Fan Powered Box O.D. Outside Diameter TP Traverse or Test Point <br /> CR Ceiling Register FPM Feel per Minute PD Pressure Drop. TU Terminal Unit <br /> CRAC Computer Room Air Conditioner FR Field Report PH Phase UH Unit Heater <br /> CRU Computer Room Unit FT Fool,Feet PHC Preheat Coil VAV Variable Air Volume;box that <br /> CT Cooling Tower FTU Fan Terminal Unit Prim. Primary contains a motorized damper that <br /> CU Condenser Unit GPM Gallons per Minute PSI Pounds per Square Inch modulates airflow. <br /> CUH Cabinet Unit Heater HC Heating Coil RA Return Air VD Volume Damper <br /> CWS Condenser Water Supply HD Pressure Difference across the entering RAT Return Air Temperature VFD Variable Frequency Drive <br /> CWR Condenser Water Return and leaving side of a pump. RF Return Fan Velgrid Instrument that reads used to read <br /> DAT Discharge Air Temperature Heater O.L. Thermal manned protection for motors RH Relative Humidity velocity in feet per minute. <br /> DB Dry Bulb located at the motor starter(starter heaters) RHC Reheat Coil VP Velocity Pressure <br /> DD Direct Drive HEPA High Efficiency Particulate Arreswnce RPM Revolutions per Minute VVT Variable Volume Terminal <br /> DDC Direct Digital Controls:EMS Control HOA Hand/Off/Auto Switch RTU Roof Top Unit W.C. Water Column <br /> System for the HVAC HP Horsepower RVA Rotating Vane Anemometer-reads W.G. Water Gauge <br /> Delta (n)Difference,net decrease or increase HRC Heat Recovery Coil air velocity in feet per minute WB Wet Bulb <br /> Des. Design HUH Hydronic Unit Heater SA Supply Air <br />