My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1130 W MARINE VIEW DR MARITIME INSTITUTE 2024-06-24
>
Address Records
>
W MARINE VIEW DR
>
1130
>
MARITIME INSTITUTE
>
1130 W MARINE VIEW DR MARITIME INSTITUTE 2024-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2024 9:04:59 AM
Creation date
5/28/2024 2:56:17 PM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1130
Tenant Name
MARITIME INSTITUTE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEUDORFER Rip-"ENGINEERS <br /> AN Integra COMPANY WW <br /> W .NEUDORFERENGINEERS,COM <br /> Fan Coil <br /> PROJECT: PAC Maritime Institure Change Order DATE: 12/22/2023 <br /> LOCATION: Everett, CONTACT: Alex Lebedev <br /> PROJECT#: 2023-1510 <br /> SYSTEM/UNIT: AH-01 Tested By: Alex Lebedev <br /> Date: 12/22/2023 <br /> Unit Data Motor Data <br /> Unit Manufacturer Rheem Motor HP 3/4 HP <br /> Unit Model Number RH1T4824STANDA Motor Rated Volts 480 Volts <br /> Unit Serial Number W451931929 Motor Phase 1 PH <br /> Drive Type Direct Drive Motor Hertz 60 Hz <br /> Fan Speed Low(Terminal 4 on the motor) Motor FL Amps 3.2 Amps <br /> Test Data Test Pressures <br /> Total Design Flow 1610 CFM Fan Suction SP -0.70 in.we <br /> Total Actual Flow 1810 CFM Fan Discharge SP 0.20 in.we <br /> RA Actual Flow 1610 CFM Actual Total SP 0.90 in.we <br /> OA Design Flow 180 CFM Actual External SP 0.27 in.we <br /> OA Actual Flow 200 CFM <br /> Motor Volts T1-T2 490 Volts Filter Data <br /> Motor Amps T1 1.9 Amps Filter Manufacturer Glassfloss <br /> Filter Type Pleated <br /> Filter Qty-S1 1 <br /> Filter Size-S1 24x24x2 <br /> Log: AH-01 12/22/2023 Alex Lebedev (1)The volume damper is full open. <br /> AH-01 12/22/2023 Alex Lebedev Unit was tested with new filters. <br /> AH-01 Supply Outlet Summary <br /> System/Unit Area Served Type of Outlet Size LxW/D AK Design Prelim Final Final% Remarks <br /> Reading Type Airflow Airflow Airflow <br /> Outlet-01 Open 104 Flowhood SD-1 10 1.00 320 355 360 113 <br /> Outlet-02 Vocational 103 Flowhood SD-1 10 1.00 355 325 390 110 (1) <br /> Outlet-03 Vocational 102 Flowhood SD-1 6 1.00 110 175 115 105 <br /> Outlet-04 Vocational 102 Flowhood SD-1 10 1.00 275 380 315 115 <br /> Outlet-05 Vocational 102 Flowhood SD-1 10 1.00 275 380 315 115 <br /> Outlet-06 Vocational 102 Flowhood SD-1 10 1.00 275 405 315 115 <br /> Totals: - - - - 1 1610 2020 1810 112 - <br /> AH-01 Return Inlet Summary <br /> System/Unit Area Served Type of Inlet Size LxW/D AK Design Prelim Final Final% Remarks <br /> Reading Type Airflow Airflow Airflow <br /> Inlet-01 Vocational 103 Flowhood RG 14 1.00 N/A 420 420 <br /> Inlet-02 Vocational 102 Flowhood RG 18 1.00 N/A 1190 1190 <br /> Inlet-03 OSA Calculated Calculate N/A 1.00 180 200 200 111 <br /> d <br /> Totals: - - - - 180 1810 1810 1006 - <br /> Neudorfer Engineers <br />
The URL can be used to link to this page
Your browser does not support the video tag.