Laserfiche WebLink
TFP172 <br />Page 3 of 4 <br />Sprinkler Fmish8 <br />K-Factor <br />Type <br />Temperature <br />Bulb Liquid <br />Color <br />Natural <br />Brass <br />Chrome <br />Plated <br />polyester= <br />135°F (57°C) <br />Orange <br />UPRIGHT <br />(TY313) <br />155°F(68°C) <br />Red <br />175°F (79°C) <br />Yellow <br />and <br />1, 2, 3, 4, 5, 6, 7 <br />PENDENT <br />(TY323) <br />200°F (93°C) <br />Green <br />5.6 <br />1/2 in. NPT <br />286-F(141°C) <br />Blue <br />135°F (57°C) <br />Orange <br />RECESSED <br />PENDENT <br />(TY323) <br />Figures 4- and 56 <br />1 2 3 4 7 <br />° 155F (68°C) <br />Red <br />175°F (79°C) <br />Yellow <br />200°F (93°C) <br />Green <br />Notes: <br />1. Listed by Underwriters Laboratories Inc (UL) as Quick Response Sprinklers. <br />2. Listed by Underwriters Laboratories Inc for use in Canada(C-UL) as Quick Response Sprinklers. <br />3. Approved by Factory Mutual Research Corporation(FM) as Quick Response Sprinklers. <br />4. Approved by the City of New York under MEA354-01-E. <br />5. VdSApproved(For details , contact Johnson Controls, Enschede, Netherlands ,Tel .3153-428-4444/Fax 3154-428-3377) <br />6. Approved by the Loss Prevention Certification Board (LPCBRef .No.094a/06) as Quick Response Sprinklers. <br />7 EAC Approved <br />8. Where Polyester Coated Sprinklers are noted to be UL and C-ULListed the sprinklers are UL and C-UL Listed as Corrosion -Resistant Sprinklers. <br />a Installed with Style 15 (1/2 in.NPT)5/8in. Total Adjustment Recessed Escutcheon, as applicable. <br />b. Installed with Style 20 (1/2 in NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. <br />c. Frame and Deflector only Listings and approvals apply to color (Special Order). <br />TABLE A <br />LABORATORY LISTINGS AND APPROVALS FOR <br />5.6 K-FACTOR SPRINKLERS <br />Operation <br />The glass bulb contains a fluid which <br />expands when exposed to heat. When <br />the rated temperature is reached, the <br />fluid expands sufficiently to shatter the <br />glass bulb, allowing the sprinkler to <br />activate and water to flow. <br />Design <br />Criteria <br />The TYCO Series TY-FRB, 5.6 K-factor, <br />Upright (TY313) and Pendent (TY323) <br />Sprinklers are intended for fire protec- <br />tion systems designed in accordance <br />with the standard installation rules <br />recognized by the applicable Listing or <br />Approval agency (such as, UL Listing <br />is based on the requirements of NFPA <br />13, and FM Approval is based on the <br />requirements of FM's Loss Prevention <br />Data Sheets). Only the Style 15 or Style <br />20 Recessed Escutcheon is to be used <br />for recessed pendent installations. <br />Installation <br />The TYCO Series TY-FRB, 5.6 K-factor, <br />Upright (TY313) and Pendent (TY323) <br />Sprinklers must be installed in accor- <br />dance with this section. <br />General Instructions <br />Do not install any bulb -type sprin- <br />kler if the bulb is cracked or there is <br />a loss of liquid from the bulb. With the <br />sprinkler held horizontally, a small air <br />bubble should be present. The diam- <br />eter of the air bubble is approximately <br />1/16 in. (1,6 mm) forthe 135°F (57°C) and <br />3/32 in. (2,4 mm) for the 286°F (141°C) <br />temperature ratings. <br />A leak -tight 1/2 in. NPT sprinkler joint <br />should be obtained by applying a <br />minimum to maximum torque of 7 to <br />14 lb-ft (9,5 to 19,0 N-m). Higher levels <br />of torque can distort the sprinkler Inlet <br />with consequent leakage or impairment <br />of the sprinkler. <br />Do not attempt to compensate for <br />insufficient adjustment in the Escutch- <br />eon Plate by under- or over -tightening <br />the sprinkler. Re -adjust the position of <br />the sprinkler fitting to suit. <br />Upright and Pendent Sprinklers <br />The Series TY-FRB Upright and <br />Pendent Sprinklers must be installed <br />in accordance with the following <br />instructions. <br />Step 1. Install Pendent sprinklers in the <br />pendent position. Install upright sprin- <br />klers in the upright position. <br />Step 2. With pipe -thread sealant <br />applied to the pipe threads, hand - <br />tighten the sprinkler into the sprinkler <br />fitting. <br />Step 3. Tighten the sprinkler into the <br />sprinkler fitting using only the W-Type <br />6 Sprinkler Wrench as shown in Figure <br />2. Apply the W-Type 6 Sprinkler -Wrench <br />to the wrench flats as shown in Figure <br />1. Torque sprinklers 7 to 14 lb-ft (9,5 to <br />19,0 N m). <br />Recessed Pendent Sprinklers <br />The Series TY-FRB Recessed Pendent <br />Sprinklers must be installed in accor- <br />dance with the following instructions. <br />Step A. After installing the Style 15 <br />or Style 20 Mounting Plate over the <br />sprinkler threads, and with pipe -thread <br />sealant applied to the pipe threads, <br />hand -tighten the sprinkler into the <br />sprinkler fitting. <br />Step B. Tighten the sprinkler into the <br />sprinkler fitting using only the W-Type <br />7 Recessed Sprinkler Wrench as <br />shown in Figure 3. Apply the W-Type <br />7 Recessed Sprinkler Wrench to the <br />sprinkler wrench flats as shown in <br />Figure 1. Torque sprinklers 7 to 14 lb-ft <br />(9,5 to 19,0 N-m). <br />Step C. After ceiling installation and <br />finishing, slide on the Style 15 or Style <br />20 Closure over the Series TY-FRB <br />Sprinkler and push the Closure overthe <br />Mounting Plate until its flange comes in <br />contact with the ceiling. <br />