Laserfiche WebLink
TFP172 <br />Page 4 of 4 <br />P/Na 77 — XXX — X — XXX <br />SIN SPRINKLER <br />TEMPERATURE <br />FINISH <br />RATINGS <br />370 5.6K UPRIGHT (1/2 in.NPT) TY313 1 NATURAL BRASS <br />135 <br />135°F (57°C) <br />371 5.6K PENDENT (1/2 in.NPT) TY323 3 PURE WHITE (RAL9010)e <br />POLYESTER <br />155 <br />155°F (68°C) <br />Notes: SIGNAL WHITE (RAL9003) <br />a Use suffix "I" for ISO 7-1 connection, for example, 4 POLYESTER <br />175 <br />175-F(79°C) <br />77-370-4-175-I <br />5 JET BLACK(RAL9005) <br />200 <br />200°F(93°C) <br />POLYESTER <br />9 CHROME PLATED <br />286 <br />286-F(141°C) <br />Notes: <br />a Eastern Hemisphere sales only <br />TABLE B <br />SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS <br />PART NUMBER SELECTION <br />Care and <br />Maintenance <br />The TYCO Series TY-FRB, 5.6 K-factor, <br />Upright (TY313) and Pendent (TY323) <br />Sprinklers must be maintained and ser- <br />viced in accordance with this section. <br />Before closing a fire protection system <br />main control valve for maintenance <br />work on the fire protection system <br />that it controls, obtain permission to <br />shut down the affected fire protection <br />systems from the proper authorities <br />and notify all personnel who may be <br />affected by this action. <br />Absence of the outer piece of an <br />escutcheon, which is used to cover <br />a clearance hole, can delay sprinkler <br />operation in a fire situation. <br />The owner must assure that the sprin- <br />klers are not used for hanging any <br />objects and that the sprinklers are only <br />cleaned by means of gently dusting <br />with a feather duster; otherwise, non - <br />operation in the event of a fire or inad- <br />vertent operation may result. <br />Sprinklers which are found to be <br />leaking or exhibiting visible signs of <br />corrosion must be replaced. <br />Automatic sprinklers must never be <br />painted, plated, coated, or other- <br />wise altered after leaving the factory. <br />Modified sprinklers must be replaced. <br />Sprinklers that have been exposed to <br />corrosive products of combustion, but <br />have not operated, should be replaced <br />if they cannot be completely cleaned <br />by wiping the sprinkler with a cloth or <br />by brushing it with a soft bristle brush. <br />Care must be exercised to avoid <br />damage to the sprinklers before, <br />during, and after installation. Sprin- <br />klers damaged by dropping, striking, <br />wrench twist/slippage, orthe like, must <br />be replaced. Also, replace any sprin- <br />klerthat has a cracked bulb orthat has <br />lost liquid from its bulb. (Ref. Installa- <br />tion Section.) <br />The owner is responsible for the <br />inspection, testing, and maintenance of <br />their fire protection system and devices <br />in compliance with this document, as <br />well as with the applicable standards <br />of the National Fire Protection Associ- <br />ation such as NFPA 25, in addition to <br />the standards of any other authorities <br />having jurisdiction. Contact the install- <br />ing contractor or product manufacturer <br />with any questions. <br />Automatic sprinkler systems are rec- <br />ommended to be inspected, tested, <br />and maintained by a qualified Inspec- <br />tion Service in accordance with local <br />requirements and/or national codes. <br />Limited <br />Warranty <br />Forwarranty terms and conditions, visit <br />www.tyco-fire.com. <br />Ordering <br />Procedure <br />Contact your local distributor for avail- <br />ability. When placing an order, indicate <br />the full product name and Part Number <br />(P/N). <br />Sprinkler Assemblies with NPT <br />Thread Connections <br />Specify: Series TY-FRB Upright or <br />Pendent (specify) Sprinkler, SIN <br />(specify), K=5.6, Quick Response, <br />(specify) temperature rating, (specify) <br />finish, P/N (specify, referto Table A). <br />Recessed Escutcheon <br />Specify: Style 15 Recessed Escutch- <br />eon with (specify*) finish, P/N (specify*) <br />Specify: Style 20 Recessed Escutch- <br />eon with (specify*) finish, P/N (specify*) <br />` Refer to Technical Data Sheet TFP770 <br />Sprinkler Wrench <br />Specify: W-Type 6 Sprinkler Wrench, <br />P/N 56-000-6-387 <br />Specify: W-Type 7 Sprinkler Wrench, <br />P/N 56-850-4-001 <br />1467 E I mwood Avenue. Cranston. <br />6CGiCf-iQ-I <br />es 2022 Johnson Controls All nems reserved_All specifications and other Information shown were current as of doe unnent reason date and are subject toe hange without notice_ <br />Johnson 00 <br />Controls <br />