Laserfiche WebLink
• <br /> FA/up Meeting for B2204-035 a • X et 0 <br /> 0 James Brooder<JBronder@overettwa.gov, G�SOP 30,2022,1:16 PM {r «, j <br /> tome,allunt@vissereng,neoring.com,Tony <br /> CI HI Manford end Allen, <br /> Background:The original construction of the building was constructed under building permit number 80604.051.under the International Building Code(IBC)2003,Canstruotlon of <br /> the building had ceased and this permit has expired without receiving final inspections for the work associated with the existing shell structure.A new building permit,B2204-035. <br /> tt{ was applied for with the Intent to construct Interior improvements within the shell structure. <br /> Per the Zoom meeting on Monday,0(28,this is to confirm the following approach is acceptable and to require that additional information be submitted for review in conjunction with <br /> IE the current permit submittal(B2204035)to faciihate the completion of the existing shell structure work, <br /> 1.It is required that the design team demonstrate that the existing shell structure(structural and non-structural)are In compliance with the requirements of the building code <br /> (IBC)at the time of the original permit submittal.Per the original building permit plans from permit B0804.051,this corresponds to IBC 2003.Special Inspection final <br /> reports attesting to the completion of the existing shell work as per the requirements listed in the original design documents submitted would satisfy some of these <br /> requirements In addition to addressing the outstanding issues(see Item 3). <br /> 2.New exterior wont as part of the B2204035 permit shall be constructed to the current coda requirements at the time of submission.IBC 2018 with WA State Amendments. <br /> Where exterior cladding Is being modified along the existing shell,It is permitted that this cladding demonstrate compliance with the IBC 2003. <br /> 3.Addressing outstanding structural and rron.strucfural issues associated with existing shell structure in the letter Issued by Steve Miller dated April 28,2007. <br /> Please IN me know if there were additional Items not captured In these requirements for the existing shot structure. <br /> Thank you, <br /> 2. The Digital Record Archives of this project indicate outstanding construction <br /> issues that have not been resolved datingfrom April 2007 duringthe initial <br /> p <br /> construction of the project. Please refer to attached. Please also have these <br /> issues resolved by the design team and included in the construction plans for <br /> this permit in addition to the intended proposed interior TI work as this <br /> concerns the state of the building envelope and structure (refer to Item 1). <br /> Architect response:See Structural response letter and drawings. <br /> ARCHITECTURAL • <br /> 1. On Sheet A0.2,the proposed mezzanine/storage space appears to indicate a <br /> Group A-3 occupancy for the space. However,an occupant load of 6 is being <br /> proposed. Please confirm that a higher occupant load for the space is not <br /> required and that an S1 occupancy is intended for the space. Please update <br /> plans as required. IBC 107.2.1. <br /> Architect response:An S1 occupancy is intended for the space. See revised <br /> A0.2. <br /> 2. On Sheet A0.2,the proposed Classroom 2 with the enclosure of movable <br /> partitions does not have an exit access doorway and door. An exit access <br /> yI <br /> 2a <br /> Page\of\ <br />