My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6900 WETMORE AVE SEATTLE BETHANY CHURCH 2024-10-25
>
Address Records
>
WETMORE AVE
>
6900
>
SEATTLE BETHANY CHURCH
>
6900 WETMORE AVE SEATTLE BETHANY CHURCH 2024-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2024 2:15:30 PM
Creation date
6/4/2024 10:53:55 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
6900
Tenant Name
SEATTLE BETHANY CHURCH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> FA/up Meeting for B2204-035 a • X et 0 <br /> 0 James Brooder<JBronder@overettwa.gov, G�SOP 30,2022,1:16 PM {r «, j <br /> tome,allunt@vissereng,neoring.com,Tony <br /> CI HI Manford end Allen, <br /> Background:The original construction of the building was constructed under building permit number 80604.051.under the International Building Code(IBC)2003,Canstruotlon of <br /> the building had ceased and this permit has expired without receiving final inspections for the work associated with the existing shell structure.A new building permit,B2204-035. <br /> tt{ was applied for with the Intent to construct Interior improvements within the shell structure. <br /> Per the Zoom meeting on Monday,0(28,this is to confirm the following approach is acceptable and to require that additional information be submitted for review in conjunction with <br /> IE the current permit submittal(B2204035)to faciihate the completion of the existing shell structure work, <br /> 1.It is required that the design team demonstrate that the existing shell structure(structural and non-structural)are In compliance with the requirements of the building code <br /> (IBC)at the time of the original permit submittal.Per the original building permit plans from permit B0804.051,this corresponds to IBC 2003.Special Inspection final <br /> reports attesting to the completion of the existing shell work as per the requirements listed in the original design documents submitted would satisfy some of these <br /> requirements In addition to addressing the outstanding issues(see Item 3). <br /> 2.New exterior wont as part of the B2204035 permit shall be constructed to the current coda requirements at the time of submission.IBC 2018 with WA State Amendments. <br /> Where exterior cladding Is being modified along the existing shell,It is permitted that this cladding demonstrate compliance with the IBC 2003. <br /> 3.Addressing outstanding structural and rron.strucfural issues associated with existing shell structure in the letter Issued by Steve Miller dated April 28,2007. <br /> Please IN me know if there were additional Items not captured In these requirements for the existing shot structure. <br /> Thank you, <br /> 2. The Digital Record Archives of this project indicate outstanding construction <br /> issues that have not been resolved datingfrom April 2007 duringthe initial <br /> p <br /> construction of the project. Please refer to attached. Please also have these <br /> issues resolved by the design team and included in the construction plans for <br /> this permit in addition to the intended proposed interior TI work as this <br /> concerns the state of the building envelope and structure (refer to Item 1). <br /> Architect response:See Structural response letter and drawings. <br /> ARCHITECTURAL • <br /> 1. On Sheet A0.2,the proposed mezzanine/storage space appears to indicate a <br /> Group A-3 occupancy for the space. However,an occupant load of 6 is being <br /> proposed. Please confirm that a higher occupant load for the space is not <br /> required and that an S1 occupancy is intended for the space. Please update <br /> plans as required. IBC 107.2.1. <br /> Architect response:An S1 occupancy is intended for the space. See revised <br /> A0.2. <br /> 2. On Sheet A0.2,the proposed Classroom 2 with the enclosure of movable <br /> partitions does not have an exit access doorway and door. An exit access <br /> yI <br /> 2a <br /> Page\of\ <br />
The URL can be used to link to this page
Your browser does not support the video tag.