Laserfiche WebLink
SECTION 01 10 00 <br />SUMMARY OF WORK <br />PART1 GENERAL <br />1.01 SUMMARY <br />A. This Section describes a project to construct one 8 million gallon reinforced and partially buried <br />concrete reservoir, shoring systems, electrical and instrumentation and control systems, and <br />associated piping and other appurtenances, including steel piping, trench and reservoir <br />excavation, haul, backfill, and spoils disposal. The 8-MG reservoir is Phase 1 of the overall <br />project and this reservoir is called Reservoir 3A. The work also includes two off site pipe <br />connections near Reservoir 2. An area on the site has been designated as Zone A and <br />excavated material from this zone may contain PFAS. Spoils from Zone A shall be stockpiled <br />onsite and left for reuse onsite in Phase 2 of this project. Phase 2 is not part of this contract.. <br />1.02 LOCATION <br />A. The Project is located in Everett, Washington, and Reservoir 3A is located on City of Everett <br />property at 6107 Evergreen Way, Everett, WA 98203. The site also contains three existing <br />pump stations, a cellular tower, and the existing 20-MG covered reservoir which must remain in <br />service during Phase 1 work. <br />B. The Project also includes two pipe connections and cut/caps east of Reservoir 2 at the <br />intersection of Tulalip and Charles Avenue and the intersection of Federal and Edward Avenue. <br />C. Dredged Sand soils for the backfill on the Reservoir 3A site shall be City -owned soils currently <br />at the City owned property located along the west bank of the Snohomish River near the <br />intersection of 1-5 and US 2. Site is gated - arrange for gate access. <br />1.03 COORDINATION OF DRAWINGS AND SPECIFICATIONS <br />A. The above limited description of work does not in any way limit the responsibility of the <br />Contractor to perform all work and furnish all equipment, labor and materials required by the <br />Contract Documents. <br />B. No attempt has been made in these Contract Documents to segregate work covered by any <br />trade or subcontract under a single specification. Such segregation and establishment of <br />subcontract limits will be solely a matter of agreement between the Contractor and its <br />subcontractors. <br />C. The Contract Documents are intended to describe and provide for a complete project. Any <br />requirement in one is as binding as if stated in all. The Contractor shall provide all work and <br />materials clearly implied in the Contract Documents even if the Contract Documents do not <br />mention it specifically. If there is a conflict within the Contract Documents it will be resolved by <br />the following order of precedence, per Section 00 72 00 subsection 1.2 1-12. <br />D. Dimensions shown on the Drawings or that can be computed from the Drawings shall take <br />precedence over scaled dimensions. Notes on Drawings shall take precedence over Drawing <br />details. <br />E. The intent of the Drawings and specifications is to prescribe the construction and completion of <br />the work which the Contractor will perform according to the terms of the Contract. Where the <br />Drawings or specifications describe portions of the work in general terms, but details are <br />incomplete or silent, it is understood that the Contractor shall use only the best general <br />practices. Unless otherwise specified, the Contractor shall furnish all labor, materials, tools, <br />Reservoir 3 Replacement Phase 1 SUMMARY OF WORK March 2024 <br />Work Order No. UP3739 01 10 00 <br />